My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1250 French Creek Drive - Septic Compliance
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1250 French Creek Drive - 10-117-23-32-0013
>
Septic
>
1250 French Creek Drive - Septic Compliance
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2025 2:42:43 AM
Creation date
9/5/2025 9:35:08 AM
Metadata
Fields
Template:
Address
Street Name
French Creek Drive
House Number
1250
Address
1250 French Creek Drive
PIN
10-117-23-32-0013
Address Doc Type
Septic Compliance
Section
Septic
Retention Effective Date
8/21/2025
Retention
After
Protection
Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MINNESOTA POLLUTION Sewage tank integrity assessment form <br />0 1 N I CONTROL AGENCY g Y <br />520 Lafayette Rudd North Subsurface Sewage <br />St. Paul, MN 55155-4194 Treatment Systems (SSTS) Program <br />Doc Type: Compliance and Enforcement <br />Purpose: This form may be used to certify the compliance status of the sewage tank components of the SSTS. This form is not a <br />complete SSTS inspection report, only a tank integrity assessment, and may only certify sewage tank compliance status <br />when entirely completed and signed by a qualified professional. SSTS compliance inspection report forms can be found at: <br />htts-s //www.pca.state.mn.us/water/inspections. <br />Instructions: This form may be completed, and signed, by a Designated Certified Individual (DCI) of a licensed SSTS inspection, <br />maintenance, installation, or service provider business who personally conducts the necessary procedures to assess the compliance <br />status of each sewage tank in the system. Only a licensed maintenance business is authorized to pump the tank for assessment. A <br />copy of this information should be submitted to the system owner and be maintained by the licensed SSTS business for a period of <br />five (5) years from the assessment date. <br />When this form is signed by a qualified certified professional, it becomes necessary supporting documentation to an Existing <br />System Compliance Inspection Report: Compliance inspection form - Existing. system w -wwists4-31 b). This form can be found on <br />the MPCA website at https://www-pca.state.mn.us/water/inspections. <br />The information and certified statement on this form is required when existing septic tank compliance status is determined by an <br />individual other than the SSTS Inspector that submits an inspection report. This form represents a third party assessment of SSTS <br />component compliance and is allowable under Minn. R. 7082.0700, subp. 4(B)(1). This form is valid for a period of three years <br />beyond the signature date on this form unless a new evaluation is requested by the owner or owner's agent or is required according <br />to local regulations. Additional Administrative Rule references for this activity can be found at Minn. R. 7082.0700, subp. 4(B),(C), <br />and (D) and; Minn. R. 7083.0730(C). <br />Owner information <br />Owner/Representative Truxton Morrison <br />Property address: 1250 French Creek Drive Wayzata, MN 55391 <br />Local Regulatory Authority: Parcel ID: <br />System status <br />System status on date (mm/dd/yyyy): 11 /14/2024 <br />❑ Certificate of sewage tank compliance ❑ Notice of sewage tank non-compliance <br />Compliance criteria: <br />The SSTS has a seepage pit, cesspool, drywell, leaching pit, or other pit - "Failure to Protect <br />Groundwater." ❑Yes` No <br />The SSTS has a sewage tank that leaks below the designed operating depth - "Failure to Protect ❑ Yes- ® No <br />Groundwater." <br />The SSTS presents a threat to public safety by reason of structurally unsound (damaged, cracked, <br />or weak) maintenance hole cover(s) or lids or any other unsafe condition - "Imminent Threat to ❑ Yes- E] No <br />Public Health or Safety." <br />Any "yes" answer above indicates sewage tank non-compliance. <br />Company information <br />Company name: Elmer J. Peterson Co <br />Business license number: 219 <br />Designated Certified Individual (DCI) information <br />Print name: James L Braegelmann <br />Certification number: <br />I personally conducted the work described above as a Designated Certified Individual of a Minnesota -licensed SSTS inspection, <br />maintenance, installation, or service provider Business. I personally conducted the necessary procedures to assess the compliance <br />status of each sewage tank in this SSTS. <br />By typing/signing my name below. I certify the above statements to be true and correct. to the best of my knowledge, and that <br />this information can be used for the purpose of processing this form. <br />Designated Certified Individual's signature: James L Braegelmann Date (mm/dd/yyyy): 11/14/2024 <br />(This document has been electronically signed.) <br />www.pca.state.mn.us 651-296-6300 800-657-3864 0 Use your preferred relay service Available in afternative formats <br />wq-wwists4-91 • 5110121 Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.