* MANUF. 12E5I6NE12 ROOF TRUSSES <br />* VENT ROOF I SOFT. PER 200 SOFT 50% ROOF 50% SOFFIT <br />* KICKOUT FLASHING TO BE INSTALLED AS NEEDED BY ROOFING CONTRACTOR <br />EXTERIOR WALL FINISHER TO VERIFY THAT K16KOUT FLASHING 15 INSTALLED <br />PRIOR TO FINISHING <br />* FULL ICE & WATER 5HIEL19 AT ROOF PITCHES 4/12 AND BELOW <br />* TRUSS MANUF. TO GALL DFP PLANNING & DESIGN WITH ANY QUESTIONS DURING LAYOUT <br />* BUILDER TO REVIEW TRU55 DESIGN & LAYOUT PRIOR TO ORDERING TRUSSES <br />ROOF PLAN <br />SCALE; 1/8" = 1'-0" <br />I. ICE & WATER 5HIELD ALL VALLEYS <br />ICE & WATER SHIELD 24" UP ALL WALLS <br />WHERE ROOF RUNS ALONG WALL <br />* ALL 5GREW5 OR NAILS BEING <br />DRILLED THROUGH STUCCO OR <br />50I1\16 MUST BE PRE-PRILLED <br />AND SEALED W/ SILICONE TO <br />PREVENT WATER LEAKAGE <br />* ALL SUBCONTRACTORS MUST SEAL <br />ALL PENETRATIONS TO EXTERIOR OF <br />HOUSE WHEN ANY HOLES ARE GUT OR <br />PENETRATIONS ARE COMPLETED <br />* FLASH ALL WINPOW5 AND 12OOR5 <br />K16KOUT FLASHING TO BE INSTALLED <br />BY ROOFER5 <br />2. CONTINUOUS VAPOR BARRIER AT <br />ALL WALL FRAMING TO EXTERIOR <br />AND ON TOP OF ALL TOP PLATES <br />TAPE ALL VAPOR BARRIERS. <br />FOAM ALL WIRES AND ITEMS THAT <br />PENETRATE VAPOR BARRIER, FOAM <br />AROUND ALL WINPOW5 AND DOORS. <br />TO ATTIC. <br />ALL CANTILEVERS, CORNERS, & RIMS <br />TO BE COVERED W/ BLDG. PAPER <br />PRIOR TO 5112IN6. <br />5TUC60 / 5TONE ATTA6HMENT <br />I. GALL FOR INSPECTION TO VERIFY COMPLIANCE WHEN PAPER <br />15 COMPLETE IN ONE WINDOW AREA. <br />2. WEATHER RE515TIVE BARRIERS: <br />WEATHER RESISTIVE BARRIERS OVER WOOD BA5E12 SHEATHING <br />SHALL INCLUDE 2 LAYERS OF GRADE D PAPER, NOTE TYPE <br />15 OR 15" FELT 15 NOT GRADED PAPER. VERTICAL JOINTS IN <br />PAPER SHALL BE LAPPED AT LEAST 2 INGHE5 <br />3. EXTERIOR OPENIN65 FLASHED: <br />EXTERIOR OPF-NINC75 SHALL BE FLASHED. THE NAILING FLANGE <br />ON WINDOWS WILL NOT BE ACCEPTED FOR FLASHING UNLESS THE <br />MANUFACTURERS INSTALLATION INSTRUCTIONS ARE PROVIDED ON <br />SITE STATING THE FLANGE 15 ACCEPTABLE AS FLASHING. <br />4. WINDOW FLANGES: <br />PAPER SHALL BE INSTALLED ON THE BOTTOM AND SIDES OF WINDOW <br />BEFORE INSTALLING WINDOW. PAPER ON THE TOP OF WINDOW SHALL <br />GO OVER THE WINDOW FLASHING. A 5ECOND LAYER OF PAPER SHALL <br />BE INSTALLED OVER THE 5112E WINDOW FLAN665 <br />5. WINDOW OPENIN65� <br />CAULK OR TAPE WINDOW OPENINGS TO MAKE THEM WATERPROOF. <br />OTHER OPF-NINC75 MUST BE CAULKED WEATHERPROOF. <br />6. PAPER ENTIRE WALL: <br />PAPER MUST BE INSTALLED ON THE ENTIRE WALL INCLUDING <br />WITHIN THE SOFFIT FRAMING. ALL PAPER MUST BE INSTALLED <br />SHINGLE FASHION TO DRAIN OUT. <br />7. FLASHING: <br />KICKOUT FLASHING 15 REQUIRED AT WALL/ROOF INTER56CTIONS <br />WHERE THE ROOF LINE 00E5 NOT EXTEND PAST THE WALL. <br />OTHER OPENINGS SHALL BE FLA5HED TO MAKE THEM WEATHERPROOF. <br />8. WEEP 5GREE12: <br />A CORRO51ON RE515TANT WEEP 5GREED WITH A MINIMUM VERTICAL <br />ATTACHMENT FLANGE OF 3 1/2" INCHES SHALL BE PROVIDED AT OR <br />BELOW THE FOUNDATION PLATE. THE 5GREED MUST BE PLACED A <br />MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE <br />CONCRETE AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED <br />WATER TO DRAIN TO THE EXTERIOR. WEEP SCREE05 MAY BE <br />JUST BELOW THE PLATE LINE OR MAY EXTEND ONTO THE <br />FOUNDATION, PROVIDED THERE 15 PAPER ON THE FOUNDATION. <br />STUCCO MUST COVER, BUT NOT EXTEND BELOW, THE <br />LATH AND PAPER <br />SEE SECTION FOR <br />5U5FLOOR INFO- <br />2x— <br />R-21 SPRAY FOAM IN5UL-:-- <br />FLOOR TRUSS PER PLAN <br />NOTE: <br />EXTERIOR WATERPROOFING 15 NOT <br />REQUIRED HERE IF CLOSED CELL <br />INSULATION SEALS THE SILL PLATE <br />AND TOP OF FOUNDATION WALL <br />1/2" GYP. 1312. (FUT.) <br />4 MIL POLY VAPOR (FUT.) <br />2x4 STUD5 (FUT.) <br />R5 IN5UL <br />POURED CONCRETE <br />FOUNDATION PER PLAN - <br />6 aQW0"r#10 <br />--SHEATHING ALIGNS w/ <br />FOUNDATION INSUL. <br />2-2X8 PLATES <br />2X8 TRTD PLATE <br />W/ I /2"x 15" A.B. @ 32" OC <br />SILL SEALER <br />ABOVE GRADE IN5UL. PROTECTION <br />TO EXTEND 6" BELOW GRADE <br />UP TO I I" OVERHANG <br />CANTILEVER FLOOR <br />TRUSSES 1 1/2" <br />EXT. WATERPROOF COATING <br />2ii FROM TOP OF FOOTING TO TOP <br />OF INTERIOR WALL EDGE <br />RIO FOUNDATION INSUL. <br />FULL FOUNDATION WALL DETAIL <br />* FOUNDATION WALL HELD IN 2" FROM 5HEATHIN6 ABOVE <br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOAD5 <br />SEE SECT ION <br />1�«�F��:]SiId1�C�l■ <br />1/2" GYP. BD. (FUT.) <br />4 MIL POLY VAPOR (FUT.) <br />2x2 STUDS <br />R5 INSUL. <br />SHEATHING ALIGNS <br />---W/ FOUND. IN5UL. <br />2-2X8 PLATES <br />2X8 TRTD PLATE <br />W/ I /2"x 15" A.B. @ 32" Or - <br />SILL SEALER <br />ABOVE GRADE INSUL. PROTECTION <br />TO EXTEND 6" BELOW GRADE <br />UP TO I I" OVERHANG <br />EXT. WATERPROOF COATING <br />Z" FROM TOP OF FOOTING TO TOP <br />POURED CONCRETE OF INTERIOR WALL EDGE <br />FOUNDATION PER PLAN —C-T— <br />RIO FOUNDATION IN5UL. <br />* STAIR WALLS <br />* TRIPLE 2X8 PLATE W/ 2X6 FRAMED WALL <br />FOUNDATION WALL DETAIL <br />* FOUNDATION WALL HELD IN 2" FROM SHEATHING ABOVE <br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOAD5 <br />PLAN REVIEW AND INSPECT ION ISSUES <br />This list of items may be helpful for Plan Reviewers and Building Inspectors to <br />use as a guide for enforcing the Minnesota Energy Code. The items apply to <br />IRC, one- and two-family residential dwellings. <br />The items marked with apply only to detached one- and two-family residential <br />dwellings. <br />PLAN REVIEW I55UE5 <br />FOUNDATION INSULATION <br />❑ exterior foundation wall insulation R-10 minimum <br />❑ foundation insulation extends from the top of the wall down to top of the <br />footing <br />❑ exterior foundation insulation is covered protective product from top of <br />exposed insulation to 6' below grade lever <br />CONCRETE SLAB OR UNDER -SLAB INSULATION <br />❑ slab on grade perimeter insulation R-10 minimum <br />❑ slab insulation extends from top of slab to design frost line or top of <br />footing <br />❑ floors over unheated space R-38 minimum <br />WINDOWS / DOORS / SKYLIGHTS <br />❑ average U-value is 0.32 maximum for windows and glass doors <br />❑ average U-value is 0.55 maximum for skylights <br />❑ window U-value consistent with Energy Compliance Certificate <br />MECHANICAL VENTILATION ISSUES <br />❑ residential mechanical ventilation system provides adequate ventilation <br />per code requirements* <br />❑ furnace efficiency is consistent with Energy Compliance Certificate <br />❑ protection against excessive depressurization is installed per code <br />requirements* <br />ENVELOPE INSULATION FOR PLAN REVIEW <br />❑ interior basement insulation of R-5 minimum & R- I I maximum <br />❑ ceilings with attics R-49 minimum. Roof /ceiling assemblies must have a <br />minimum 6" <br />energy heel. R-38 will be allowed when full height of <br />uncompressed R-38 extends over the exterior wall top plate at eaves <br />❑ wood framed wall insulation of R-20 or R-13 + R-5. R-13 refers to wall <br />cavity insulation, R-5 refers to continuous insulation <br />IN5PE6TI0N 155UE5 <br />CONGEALED INSULATION <br />FRAMING AND SHEATHING <br />❑ wind wash barrier installed at attic edge <br />❑ exterior wall corners framed so that insulation can be installed <br />after exterior sheathing is installed <br />❑ intersections of interior partition walls and exterior walls are <br />framed so that insulation can be installed between the partition <br />and exterior sheathing after exterior sheathing is installed <br />❑ gaps between framing less than one-half inch are eliminated by <br />securing framing together or are insulated at the time of <br />assembly <br />❑ all penetrations between conditioned and unconditioned spaces <br />made prior to framing inspection are sealed <br />❑ windows must be insulated and sealed at installation <br />INTERIOR AIR BARRIER <br />❑ all fire stops are air sealed <br />❑ pipes, ducts, wires, equipment and flues and chimneys through <br />the interior air barrier are sealed <br />❑ a sealed continuous interior air barrier is installed on the warm <br />side of the building envelope at ceilings, walls, and floor rim <br />joist areas* <br />❑ air barrier behind tub and shower is sealed and protected <br />❑ recessed light fixtures are sealed <br />ENVELOPE INSULATION <br />❑ total basement wall insulation is R-15 minimum, minimum R-10 at exterior <br />❑ wind wash barrier on wall separating house and garage is sealed <br />❑ loose fill insulation is prevented from entering the eaves <br />❑ insulation on skylight shafts and walls exposed in attics is <br />supported on the unconditioned side <br />ATTIC INSULATION <br />❑ attic access panel insulated to R-38 minimum for ceiling panel and <br />R-21 minimum for wall panel <br />❑ attic card attached to framing near access opening <br />❑ notification of attic R-value and date of installation posted near <br />building permit inspection card <br />2X8 STUDS @ 16" 0.( <br />1I-3:�(-��:ISiId 71�Cc� <br />1/2" GYP. BD. (FUT.) <br />4 MIL POLY VAPOR (FUT.) <br />2x4 STUDS (FUT.) - <br />R5 INSUL. <br />POURED CONCRETE <br />FOUNDATION PER PLAN <br />SHEATHING ALIGNS <br />W/ FOUND. IN5UL. <br />2X8 TRTD PLATE <br />W/I/2"xl2" A.B. @ 32" OC <br />SILL SEALER <br />ABOVE GRADE INSUL. PROTECTION <br />TO EXTEND 6" BELOW GRADE <br />UP TO I I" PLATE OVERHANG <br />EXT. WATERPROOF COATING <br />FROM TOP OF FOOTING TO TOP <br />OF INTERIOR WALL EDGE <br />BRIO FOUNDATION IN5UL. <br />*LOOKOUT WALLS <br />* SINGLE 2X8 PLATE W/ 2X8 FRAMED WALL <br />FOUNDATION WALL OF -TAIL <br />* FOUNDATION WALL HELD IN 2" FROM 5HEATHIN6 ABOVE <br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOADS <br />61941042[30]0I <br />SEE SECTION FOR <br />5UBFLOOR INFO <br />SHEATHING ALIGNS <br />W/ FOUND. INSUL. <br />2x <br />2-2X8 PLATES <br />R-21 SPRAY FOAM IN5UL. <br />2X8 TRTD PLATE <br />W/ I /2"x 15" A.B. @ 32" OC <br />FLOOR TRU55 PER PLAN <br />SILL SEALER <br />NOTE: <br />INSULATION PROTECTION <br />EXTERIOR WATERPROOFING 15 NOT <br />RIO FOUNDATION IN5UL. <br />REQU IRED HERE IF CLOSED CELL <br />7" <br />INSULATION SEALS THE SILL PLATE <br />UP TO I" OVERHANG <br />I <br />AND TOP OF FOUNDATION WALL______� <br />1/2" GYP. BD. (FUT.) <br />2" <br />NTILEVER FLOOR <br />FTRU55155I I /2" <br />4 MIL POLY VAPOR (FUT.) <br />2x4 STUDS (FUT.) <br />R5 INSUL. <br />I ii <br />EXT. WATERPROOF COATING <br />FROM TOP OF FOOTING TO TOP <br />POURED CONCRETE <br />OF INTERIOR WALL EDGE <br />FOUNDATION PER PLAN <br />—RIO FOUNDATION INSUL. <br />* CONNECTED TO GARAGE <br />FULL <br />FOUNDATION <br />WALL <br />DETAIL <br />* FOUNDATION WALL HELD IN 2" FROM 5HEATHIN6 ABOVE <br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOAD5 <br />SEE SECTION FOR <br />WALL INFO <br />FASTENER SPACING FOR A SOUTHERN PINE OR HEM -FIR DECK LEDGER & <br />SEE SECTION FOR ICE & WATER 5HIEL12 <br />A 2"-NOMINAL 5OL112 SAWN 5PRUCE-PIN-FIR BAND JOIST (C,F,G) <br />5U13FLO0R INFO 2X10 RIBBON <br />TABLE R507.2 <br />RE5IDENTIAL <br />DECK J015T SPAN CONNECTION DETAIL <br />LEDGER FLASHING <br />6 & LE55 <br />6-I TO 8 <br />8-I TO IO <br />10-I TO 12 <br />12-I TO 14 <br />14-I TO 16 <br />16-1 TO 18 <br />5/4" DECKING <br />FLOOR TRU55 PER PLAN <br />PLAN W/ DOUBLE TRTD J5T5 PER PLAN <br />1/2" DIAMETER LAG SCREWS <br />�� <br />W/ 15/32 MAX SHEATHING <br />30" O.G. <br />23" O.G. <br />18" O.G. <br />15" O.G. <br />13" O.G. <br />I I" O.G. <br />10" O.G. <br />VERTICAL -END -WEBS IETRTD DECK RIM <br />1/2" PIAMETER BOLTS W/ <br />36" O.G. <br />36" O.G. <br />34" O.G. <br />29" O.G. <br />24" O.G. <br />21" O.G. <br />19" O.G. <br />R-21 SPRAY FOAM INSUL. <br />I/2" HOT -DIPPED <br />15/32 MAX. SHEATHING <br />GALVANIZED LAG SCREW OR <br />ANDWASHERS, <br />1/2" DIAMETER BOLTS W/ 15/32" MAX <br />SHEATHING & 1/2" 5TACKED WASHERS (B,H) <br />ii <br />36 O.G36 <br />ii O.G. <br />ii <br />29 O.G. <br />i <br />ii <br />24 O.G. <br />i <br />ii <br />21 O.G. <br />i <br />ii <br />18 O.G.G. <br />i <br />F16"THRU-13OLT <br />,. 5TA66E13E12 <br />NOTE: <br />FOR 51: I"=25.4 MM, I FOOT =304.8 MM, I POUND PER SQUARE FOOT = 0,0479 KPA <br />INSTALL ICE & WATER 5HIELD (MIN. 36" WIDE) BEHIND DECK RIM <br />A. THE TIP OF THE LAG SCREW SHALL FULLY EXTEND BEYOND THE FLOOR TRU55 RIBBON <br />PRE DRILL DECK RIM & FILL HOLES W/ 51LICONE <br />B. THE MAXIMUM GAP BETWEEN THE FACE OF THE LEDGER BOARD & FACE OF THE WALL SHEATHING SHALL BE " <br />USE LAG SCREWS OR BOLTS TO ATTACH <br />MINIMUM OF 6 OF FLASHING INSTALLED OVER DECK RIM <br />C. LED6ER5 SHALL BE FLASHED TO PREVENT WATER FROM CONTACTING THE HOUSE FLOOR TRU55 RIBBON <br />SILICONE THREE EDGES OF DECK RIM TO ICE &WATER 5HIELD <br />D. LAG SCREWS AND BOLTS SHALL BE 5TAG6ERED IN ACCORDANCE WITH SECTION R507.2.1 <br />E. DECK LEDGER SHALL BE MINIMUM DEPT TO MATCH JOIST PRESSURE- PER5ERVATIVE- TREATED NO.2 GRADE LUMBER <br />RIM DETAIL @ D C K <br />F. EXCLUDED -NO ENGINEERED WOOD PRODUCT RIM U5E0 <br />G. EXCLUDED - NO LAMINATED VENEER PRODUCT RIM U5ED <br />SECTION VIEW <br />H. THE MAXIMUM D15TANCE BETWEEN THE FACE OF THE LEDGER BOARD & THE FACE OF THE FLOOR TRU55 RIBBON SHALL BE I" <br />TABLE R507.2.1 <br />PLACEMENT OF LAG SCREWS & BOLTS IN DECK LEDGER5 & BAND JOISTS <br />TOP EDGE <br />BOTTOM EDGE <br />ENI25 <br />ROW SPACING <br />FLOOR SHEATHING <br />NAILING AT 6" MAX. <br />LEDGER <br />O.G. TO TRU55 WITH HOLD DOWN OR <br />2 INCHES (D) <br />1/4 INCH <br />2 INCH (15) <br />1 5/8 INCH (13) <br />FLOOR TRU55 RIBBON <br />HOLD DOWN SIMILAR TENSION <br />3/4 INCH <br />2 INCH <br />2 INCH (B) <br />15/8 INCH (B) <br />FOR 51: 0=25.4 MM <br />DEV ICE <br />V <br />A. LAG 5GREW5 AND BOLTS SHALL BE 5TA66ERED FROM THE TOP TO THE BOTTOM ALONG THE HORIZONTAL RUN OF THE DECK LEDGER IN <br />FLOOR DECK J015T <br />r2/ <br />ACCORDANCE WITH FIGURE R507.2.1(1) <br />TRU55 PER <br />PER PLAN <br />B. MAXIMUM 5 INCHES <br />PLAN <br />rA <br />C. EXCLUDED NO ENGINEERED WOOD PRODUCT RIM U5E12 <br />OPTIONAL MICROLAM <br />12. THE MINIMUM D15TANCE FROM BOTTOM ROW OF LAG SCREWS OR BOLTS TO THE TOP EDGE OF THE LEDGER SHALL BE IN ACCORDANCE <br />NAILED TO SIDE OF <br />WITH FIGURE R507,2.1(1) <br />I/2" PLYWOOD TRU55 <br />SHEATHING W/ <br />FIGURE R507.2.1 1 <br />DECK CONNECTION NOTES <br />50L ID BLOCKING <br />BEHIND <br />* HOLD DOWN TENSION DEVICE MUST BE INSTALLED <br />IN NOT LE55 THAN TWO LOCATIONS PER DECK <br />* EACH DEVICE MUST HAVE AN ALLOWABLE 5TRE55 <br />DESIGN CAPACITY OF NOT LE55 THAN 1,500 POUNDS <br />R I DETA IL @ DECK <br />SECTION VIEW FIGURE 507.2.3 MODIFIED <br />FO FLOOR TRU55 <br />SEE SECTION <br />SEE SECTION FOR <br />5UBFLOOR INFO--- <br />2x R IBBON <br />SPRAY FOAM INSUL.- <br />R21 MINIMUM <br />FLOOR TRU55 PER PLAN <br />1/2" GYP BOARD <br />SEE SECTION <br />RIM DETAIL <br />o z <br />I <br />II <br />I <br />1�3" MIN. A85 OR PVC OR EQUIVALENT <br />I <br />GASTIGHT PIPE (AF103.6.1) <br />F � <br />/-PROVIDE SPACE FOR FUTURE <br />I <br />INSTALLATION OF A FAN (AF103.8) <br />* MIN. 24" DIAMETER CENTERED ON <br />THE AX15 OF THE VENT 5TA6K <br />PER PLAN L <br />J * MIN. VERTICAL 1215TANCE 36" <br />PER PLAN <br />j' INSTALL LIVE OUTLET IN ATTIC WHERE <br />I FUT. FAN MAY BE INSTALLED (AF103.12) <br />lIN <br />INSTALL LABEL READING (RADON REDUCTION <br />SYSTEM) ON THE VENT PIPE AT EACH FLOOR <br />AND IN ACCE55113LE ATTICS (AF103.4.5) <br />PER PLAN j <br />PER PLAN ALL PIPE JOINTS AND FITTINGS <br />TO BE GLUED OR TRANSITION <br />COUPLINGS <br />SEAL ALL FLOOR OPENINGS SS <br />PER PLAN J� <br />11 <br />11 <br />j I INSTALL LABEL READING (RADON REDUCTION <br />PER PLAN j SYSTEM) ON THE VENT PIPE AT EACH FLOOR <br />AND IN A66ESSI13LE ATT165 (AF103.4.5) <br />I I ALL CONTROL JOINTS, 150LATION JOINTS, <br />11 CONSTRUCTION JOINTS, AND ANY OTHER <br />1 I JOINTS IN CONCRETE 5LA135 SHALL BE <br />SEAL ALL JOINTS 5EALED WITH CAULK OR SEALANT <br />BETWEEN 5LA13 <br />AND FOUND. WALL <br />I SEALED SUMP BASKET <br />I I MIN. 6 MIL OR 3 MIL CROSS <br />4" PERFORATED DRAIN I 11 I LAMINATED POLY SHALL BE <br />TILE W/FILTER FABRIC L v J LAPPED 12" AND PLACED BELOW <br />8"X16" ROCK TRENCH THE SLAB AND ON TOP OF 4" MIN. 5AN12 GAS <br />(1 "-1 1 /2") PERMEABLE LAYER <br />PA551VE RADON DETAIL <br />SCALE: 1/4" = I'-0" <br />P I LEOGER-\ 1' 1 101 N f 101 101 <br />N LAG SCREW I I LEDGE I I-rLaaK I I TKI1ZD*- 1 1 <br />__--I—LRBOLT __LJSPLICE _L1TRU55LLRIBBON_J_I____ <br />SEE SECTION <br />SEE SECTION FOR <br />SU13FLOOR INFO-, <br />FLOOR <br />5P <br />TRUSS <br />A <br />FOAM IN3UI,. <br />PER PLAN <br />BLOCKING AS <br />READ. FIRST 3 BAYS <br />* PROVIDE ADDITIONAL <br />BLOCKING AT POINT LOADS <br />RIM DETAIL <br />* PARALLEL TO FOUNDATION <br />WALL BLOCKING <br />A. TABLES & FIGURE HAVE BEEN MODIFIED FROM CODE <br />BOOK TO REFLECT FLOOR TRU55 CONDITIONS WITH 2X1 <br />RIBBON WITH TREATED 2X10 DECK RIM <br />SEE SECTION — <br />SEE SECTION FOR <br />SU13FLOOR INFO <br />BLOCKING 13TWN TRU55E5 <br />HEAT RUN , <br />1/2" 5HTH'6 CANT, BARRIER, <br />SEAL PERIMETER, JOINTS, AND <br />OPEN ING5 <br />FLOOR TRU55 PER PLAN <br />1/2" GYP BOARD <br />RIBBON <br />SEE SECTION <br />2x RIBBON <br />SPRAY FOAM INSUL. <br />R21 MINIMUM <br />SHEATHING <br />SOFFIT <br />R-38 INSULATION MIN. <br />RIM DETAIL @ CANTILEVER <br />CEILING DRYWALL TAPED <br />TO WALL DRYWALL <br />DRYWALL CAULKED, GLUED, <br />or 6A5KETED TO TOP PLATE <br />DRYWALL CAULKED, GLUED, <br />or GASKETED TO BOTTOM PLATE <br />BOTTOM PLATE CAULKED or <br />6A5KETE12 TO SU13FLOOR <br />SPRAY FOAM INSUL. <br />R21 MINIMUM <br />DRYWALL CAULKED, GLUED, <br />or 6A5KETED TO TOP PLATE <br />DRYWALL CAULKED, GLUED, <br />or GASKETED TO BOTTOM PLATE <br />BOTTOM PLATE CAULKED or <br />GA51<ETED TO 5U13FLOOR <br />SPRAY FOAM INSUL. <br />R21 MINIMUM <br />EXTERIOR SHEATHING CAULKED, <br />GLUED, or 6ASKETE12 TO SILL PLATE <br />TRTD SILL PLATE W/ <br />SILL 5EALER/6ASKET <br />TAPED OR SEALED JOINT @ <br />EXTERIOR SHEATHING & <br />FOUNDATION INSULATION <br />OPTION # <br />ENVELOPE AIR SEALING <br />* NOTE: 5HADED COMPONENTS DESIGNATE <br />AIR FLOW RETARDER SYSTEM <br />DRUK HOMES <br />1240 ARBOR ST. <br />ORONO, MN <br />PLAN APPROVED FOR PERMIT APPLICATION FOR ADDRESS SHOWN ONLY <br />DRYWALL CAULKED, GLUED, <br />or 6ASKETE12 TO TOP PLATE <br />EXTERIOR SHEATHING CAULKED, <br />GLUED, or 6A51<ETED TO TOP PLATE <br />TAPED OR 5EALE12 JOINTS IN <br />EXTERIOR SHEATHING <br />EXTERIOR SHEATHING CAULKED, <br />GLUED, or 6A51<ETED TO BOTTOM PLATE <br />SPRAY FOAM INSUL. <br />R21 MINIMUM <br />EXTERIOR SHEATHING CAULKED, <br />GLUED, or 6A51KETED TO TOP PLATE <br />TAPED OR 5EALE12 JOINTS IN <br />EXTERIOR SHEATHING <br />EXTERIOR SHEATHING CAULKED, <br />GLUED, or 6A51<ETED TO BOTTOM PLATE <br />SPRAY FOAM INSUL. <br />R21 MINIMUM <br />EXTERIOR SHEATHING CAULKED, <br />GLUED, or GASKETED TO SILL PLATE <br />TRTD SILL PLATE W/ <br />SILL 5EALER/GA5KET <br />TAPED OR SEALED JOINT @ <br />EXTERIOR SHEATHING & <br />FOUNDATION INSULATION <br />OPTION '2 <br />ENVELOPE AIR SEALING <br />* NOTE: SHADED COMPONENTS DE5I6NATE <br />AIR FLOW RETARDER SYSTEM <br />rn 0 <br />�o <br />Lo Z 0 <br />Ln o o <br />(nCO <br />w <br />o0 <br />a- co <br />LL <br />L o <br />Z @ <br />ZQo° <br />l!RRJLL� <br />Vpjz.. <br />X <br />0 <br />�/'� J LL <br />F5 O Q <br />w w 7i <br />[-- w <br />0t <br />w w Z O <br />U'�- <br />� ZO <br />U' (D o <br />w � CO <br />zoo <br />O a- 00 <br />Z LL � <br />o ro <br />a Z a � <br />Qm <br />Jo 0 <br />m L <br />w a- <br />wF <br />O <br />o� <br />x <br />ao <br />�z <br />boa <br />� <br />�o <br />P4 <br />DATE: <br />7-5-16 <br />REVISIONS: <br />7-18-16 JP <br />DRAWN BY: <br />JP <br />COMM. NO. <br />216284 <br />SHEET NO. <br />P I <br />