* MANUF. 12E5I6NE12 ROOF TRUSSES
<br />* VENT ROOF I SOFT. PER 200 SOFT 50% ROOF 50% SOFFIT
<br />* KICKOUT FLASHING TO BE INSTALLED AS NEEDED BY ROOFING CONTRACTOR
<br />EXTERIOR WALL FINISHER TO VERIFY THAT K16KOUT FLASHING 15 INSTALLED
<br />PRIOR TO FINISHING
<br />* FULL ICE & WATER 5HIEL19 AT ROOF PITCHES 4/12 AND BELOW
<br />* TRUSS MANUF. TO GALL DFP PLANNING & DESIGN WITH ANY QUESTIONS DURING LAYOUT
<br />* BUILDER TO REVIEW TRU55 DESIGN & LAYOUT PRIOR TO ORDERING TRUSSES
<br />ROOF PLAN
<br />SCALE; 1/8" = 1'-0"
<br />I. ICE & WATER 5HIELD ALL VALLEYS
<br />ICE & WATER SHIELD 24" UP ALL WALLS
<br />WHERE ROOF RUNS ALONG WALL
<br />* ALL 5GREW5 OR NAILS BEING
<br />DRILLED THROUGH STUCCO OR
<br />50I1\16 MUST BE PRE-PRILLED
<br />AND SEALED W/ SILICONE TO
<br />PREVENT WATER LEAKAGE
<br />* ALL SUBCONTRACTORS MUST SEAL
<br />ALL PENETRATIONS TO EXTERIOR OF
<br />HOUSE WHEN ANY HOLES ARE GUT OR
<br />PENETRATIONS ARE COMPLETED
<br />* FLASH ALL WINPOW5 AND 12OOR5
<br />K16KOUT FLASHING TO BE INSTALLED
<br />BY ROOFER5
<br />2. CONTINUOUS VAPOR BARRIER AT
<br />ALL WALL FRAMING TO EXTERIOR
<br />AND ON TOP OF ALL TOP PLATES
<br />TAPE ALL VAPOR BARRIERS.
<br />FOAM ALL WIRES AND ITEMS THAT
<br />PENETRATE VAPOR BARRIER, FOAM
<br />AROUND ALL WINPOW5 AND DOORS.
<br />TO ATTIC.
<br />ALL CANTILEVERS, CORNERS, & RIMS
<br />TO BE COVERED W/ BLDG. PAPER
<br />PRIOR TO 5112IN6.
<br />5TUC60 / 5TONE ATTA6HMENT
<br />I. GALL FOR INSPECTION TO VERIFY COMPLIANCE WHEN PAPER
<br />15 COMPLETE IN ONE WINDOW AREA.
<br />2. WEATHER RE515TIVE BARRIERS:
<br />WEATHER RESISTIVE BARRIERS OVER WOOD BA5E12 SHEATHING
<br />SHALL INCLUDE 2 LAYERS OF GRADE D PAPER, NOTE TYPE
<br />15 OR 15" FELT 15 NOT GRADED PAPER. VERTICAL JOINTS IN
<br />PAPER SHALL BE LAPPED AT LEAST 2 INGHE5
<br />3. EXTERIOR OPENIN65 FLASHED:
<br />EXTERIOR OPF-NINC75 SHALL BE FLASHED. THE NAILING FLANGE
<br />ON WINDOWS WILL NOT BE ACCEPTED FOR FLASHING UNLESS THE
<br />MANUFACTURERS INSTALLATION INSTRUCTIONS ARE PROVIDED ON
<br />SITE STATING THE FLANGE 15 ACCEPTABLE AS FLASHING.
<br />4. WINDOW FLANGES:
<br />PAPER SHALL BE INSTALLED ON THE BOTTOM AND SIDES OF WINDOW
<br />BEFORE INSTALLING WINDOW. PAPER ON THE TOP OF WINDOW SHALL
<br />GO OVER THE WINDOW FLASHING. A 5ECOND LAYER OF PAPER SHALL
<br />BE INSTALLED OVER THE 5112E WINDOW FLAN665
<br />5. WINDOW OPENIN65�
<br />CAULK OR TAPE WINDOW OPENINGS TO MAKE THEM WATERPROOF.
<br />OTHER OPF-NINC75 MUST BE CAULKED WEATHERPROOF.
<br />6. PAPER ENTIRE WALL:
<br />PAPER MUST BE INSTALLED ON THE ENTIRE WALL INCLUDING
<br />WITHIN THE SOFFIT FRAMING. ALL PAPER MUST BE INSTALLED
<br />SHINGLE FASHION TO DRAIN OUT.
<br />7. FLASHING:
<br />KICKOUT FLASHING 15 REQUIRED AT WALL/ROOF INTER56CTIONS
<br />WHERE THE ROOF LINE 00E5 NOT EXTEND PAST THE WALL.
<br />OTHER OPENINGS SHALL BE FLA5HED TO MAKE THEM WEATHERPROOF.
<br />8. WEEP 5GREE12:
<br />A CORRO51ON RE515TANT WEEP 5GREED WITH A MINIMUM VERTICAL
<br />ATTACHMENT FLANGE OF 3 1/2" INCHES SHALL BE PROVIDED AT OR
<br />BELOW THE FOUNDATION PLATE. THE 5GREED MUST BE PLACED A
<br />MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE
<br />CONCRETE AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED
<br />WATER TO DRAIN TO THE EXTERIOR. WEEP SCREE05 MAY BE
<br />JUST BELOW THE PLATE LINE OR MAY EXTEND ONTO THE
<br />FOUNDATION, PROVIDED THERE 15 PAPER ON THE FOUNDATION.
<br />STUCCO MUST COVER, BUT NOT EXTEND BELOW, THE
<br />LATH AND PAPER
<br />SEE SECTION FOR
<br />5U5FLOOR INFO-
<br />2x—
<br />R-21 SPRAY FOAM IN5UL-:--
<br />FLOOR TRUSS PER PLAN
<br />NOTE:
<br />EXTERIOR WATERPROOFING 15 NOT
<br />REQUIRED HERE IF CLOSED CELL
<br />INSULATION SEALS THE SILL PLATE
<br />AND TOP OF FOUNDATION WALL
<br />1/2" GYP. 1312. (FUT.)
<br />4 MIL POLY VAPOR (FUT.)
<br />2x4 STUD5 (FUT.)
<br />R5 IN5UL
<br />POURED CONCRETE
<br />FOUNDATION PER PLAN -
<br />6 aQW0"r#10
<br />--SHEATHING ALIGNS w/
<br />FOUNDATION INSUL.
<br />2-2X8 PLATES
<br />2X8 TRTD PLATE
<br />W/ I /2"x 15" A.B. @ 32" OC
<br />SILL SEALER
<br />ABOVE GRADE IN5UL. PROTECTION
<br />TO EXTEND 6" BELOW GRADE
<br />UP TO I I" OVERHANG
<br />CANTILEVER FLOOR
<br />TRUSSES 1 1/2"
<br />EXT. WATERPROOF COATING
<br />2ii FROM TOP OF FOOTING TO TOP
<br />OF INTERIOR WALL EDGE
<br />RIO FOUNDATION INSUL.
<br />FULL FOUNDATION WALL DETAIL
<br />* FOUNDATION WALL HELD IN 2" FROM 5HEATHIN6 ABOVE
<br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOAD5
<br />SEE SECT ION
<br />1�«�F��:]SiId1�C�l■
<br />1/2" GYP. BD. (FUT.)
<br />4 MIL POLY VAPOR (FUT.)
<br />2x2 STUDS
<br />R5 INSUL.
<br />SHEATHING ALIGNS
<br />---W/ FOUND. IN5UL.
<br />2-2X8 PLATES
<br />2X8 TRTD PLATE
<br />W/ I /2"x 15" A.B. @ 32" Or -
<br />SILL SEALER
<br />ABOVE GRADE INSUL. PROTECTION
<br />TO EXTEND 6" BELOW GRADE
<br />UP TO I I" OVERHANG
<br />EXT. WATERPROOF COATING
<br />Z" FROM TOP OF FOOTING TO TOP
<br />POURED CONCRETE OF INTERIOR WALL EDGE
<br />FOUNDATION PER PLAN —C-T—
<br />RIO FOUNDATION IN5UL.
<br />* STAIR WALLS
<br />* TRIPLE 2X8 PLATE W/ 2X6 FRAMED WALL
<br />FOUNDATION WALL DETAIL
<br />* FOUNDATION WALL HELD IN 2" FROM SHEATHING ABOVE
<br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOAD5
<br />PLAN REVIEW AND INSPECT ION ISSUES
<br />This list of items may be helpful for Plan Reviewers and Building Inspectors to
<br />use as a guide for enforcing the Minnesota Energy Code. The items apply to
<br />IRC, one- and two-family residential dwellings.
<br />The items marked with apply only to detached one- and two-family residential
<br />dwellings.
<br />PLAN REVIEW I55UE5
<br />FOUNDATION INSULATION
<br />❑ exterior foundation wall insulation R-10 minimum
<br />❑ foundation insulation extends from the top of the wall down to top of the
<br />footing
<br />❑ exterior foundation insulation is covered protective product from top of
<br />exposed insulation to 6' below grade lever
<br />CONCRETE SLAB OR UNDER -SLAB INSULATION
<br />❑ slab on grade perimeter insulation R-10 minimum
<br />❑ slab insulation extends from top of slab to design frost line or top of
<br />footing
<br />❑ floors over unheated space R-38 minimum
<br />WINDOWS / DOORS / SKYLIGHTS
<br />❑ average U-value is 0.32 maximum for windows and glass doors
<br />❑ average U-value is 0.55 maximum for skylights
<br />❑ window U-value consistent with Energy Compliance Certificate
<br />MECHANICAL VENTILATION ISSUES
<br />❑ residential mechanical ventilation system provides adequate ventilation
<br />per code requirements*
<br />❑ furnace efficiency is consistent with Energy Compliance Certificate
<br />❑ protection against excessive depressurization is installed per code
<br />requirements*
<br />ENVELOPE INSULATION FOR PLAN REVIEW
<br />❑ interior basement insulation of R-5 minimum & R- I I maximum
<br />❑ ceilings with attics R-49 minimum. Roof /ceiling assemblies must have a
<br />minimum 6"
<br />energy heel. R-38 will be allowed when full height of
<br />uncompressed R-38 extends over the exterior wall top plate at eaves
<br />❑ wood framed wall insulation of R-20 or R-13 + R-5. R-13 refers to wall
<br />cavity insulation, R-5 refers to continuous insulation
<br />IN5PE6TI0N 155UE5
<br />CONGEALED INSULATION
<br />FRAMING AND SHEATHING
<br />❑ wind wash barrier installed at attic edge
<br />❑ exterior wall corners framed so that insulation can be installed
<br />after exterior sheathing is installed
<br />❑ intersections of interior partition walls and exterior walls are
<br />framed so that insulation can be installed between the partition
<br />and exterior sheathing after exterior sheathing is installed
<br />❑ gaps between framing less than one-half inch are eliminated by
<br />securing framing together or are insulated at the time of
<br />assembly
<br />❑ all penetrations between conditioned and unconditioned spaces
<br />made prior to framing inspection are sealed
<br />❑ windows must be insulated and sealed at installation
<br />INTERIOR AIR BARRIER
<br />❑ all fire stops are air sealed
<br />❑ pipes, ducts, wires, equipment and flues and chimneys through
<br />the interior air barrier are sealed
<br />❑ a sealed continuous interior air barrier is installed on the warm
<br />side of the building envelope at ceilings, walls, and floor rim
<br />joist areas*
<br />❑ air barrier behind tub and shower is sealed and protected
<br />❑ recessed light fixtures are sealed
<br />ENVELOPE INSULATION
<br />❑ total basement wall insulation is R-15 minimum, minimum R-10 at exterior
<br />❑ wind wash barrier on wall separating house and garage is sealed
<br />❑ loose fill insulation is prevented from entering the eaves
<br />❑ insulation on skylight shafts and walls exposed in attics is
<br />supported on the unconditioned side
<br />ATTIC INSULATION
<br />❑ attic access panel insulated to R-38 minimum for ceiling panel and
<br />R-21 minimum for wall panel
<br />❑ attic card attached to framing near access opening
<br />❑ notification of attic R-value and date of installation posted near
<br />building permit inspection card
<br />2X8 STUDS @ 16" 0.(
<br />1I-3:�(-��:ISiId 71�Cc�
<br />1/2" GYP. BD. (FUT.)
<br />4 MIL POLY VAPOR (FUT.)
<br />2x4 STUDS (FUT.) -
<br />R5 INSUL.
<br />POURED CONCRETE
<br />FOUNDATION PER PLAN
<br />SHEATHING ALIGNS
<br />W/ FOUND. IN5UL.
<br />2X8 TRTD PLATE
<br />W/I/2"xl2" A.B. @ 32" OC
<br />SILL SEALER
<br />ABOVE GRADE INSUL. PROTECTION
<br />TO EXTEND 6" BELOW GRADE
<br />UP TO I I" PLATE OVERHANG
<br />EXT. WATERPROOF COATING
<br />FROM TOP OF FOOTING TO TOP
<br />OF INTERIOR WALL EDGE
<br />BRIO FOUNDATION IN5UL.
<br />*LOOKOUT WALLS
<br />* SINGLE 2X8 PLATE W/ 2X8 FRAMED WALL
<br />FOUNDATION WALL OF -TAIL
<br />* FOUNDATION WALL HELD IN 2" FROM 5HEATHIN6 ABOVE
<br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOADS
<br />61941042[30]0I
<br />SEE SECTION FOR
<br />5UBFLOOR INFO
<br />SHEATHING ALIGNS
<br />W/ FOUND. INSUL.
<br />2x
<br />2-2X8 PLATES
<br />R-21 SPRAY FOAM IN5UL.
<br />2X8 TRTD PLATE
<br />W/ I /2"x 15" A.B. @ 32" OC
<br />FLOOR TRU55 PER PLAN
<br />SILL SEALER
<br />NOTE:
<br />INSULATION PROTECTION
<br />EXTERIOR WATERPROOFING 15 NOT
<br />RIO FOUNDATION IN5UL.
<br />REQU IRED HERE IF CLOSED CELL
<br />7"
<br />INSULATION SEALS THE SILL PLATE
<br />UP TO I" OVERHANG
<br />I
<br />AND TOP OF FOUNDATION WALL______�
<br />1/2" GYP. BD. (FUT.)
<br />2"
<br />NTILEVER FLOOR
<br />FTRU55155I I /2"
<br />4 MIL POLY VAPOR (FUT.)
<br />2x4 STUDS (FUT.)
<br />R5 INSUL.
<br />I ii
<br />EXT. WATERPROOF COATING
<br />FROM TOP OF FOOTING TO TOP
<br />POURED CONCRETE
<br />OF INTERIOR WALL EDGE
<br />FOUNDATION PER PLAN
<br />—RIO FOUNDATION INSUL.
<br />* CONNECTED TO GARAGE
<br />FULL
<br />FOUNDATION
<br />WALL
<br />DETAIL
<br />* FOUNDATION WALL HELD IN 2" FROM 5HEATHIN6 ABOVE
<br />* PROVIDE ADDITIONAL BLOCKING AT POINT LOAD5
<br />SEE SECTION FOR
<br />WALL INFO
<br />FASTENER SPACING FOR A SOUTHERN PINE OR HEM -FIR DECK LEDGER &
<br />SEE SECTION FOR ICE & WATER 5HIEL12
<br />A 2"-NOMINAL 5OL112 SAWN 5PRUCE-PIN-FIR BAND JOIST (C,F,G)
<br />5U13FLO0R INFO 2X10 RIBBON
<br />TABLE R507.2
<br />RE5IDENTIAL
<br />DECK J015T SPAN CONNECTION DETAIL
<br />LEDGER FLASHING
<br />6 & LE55
<br />6-I TO 8
<br />8-I TO IO
<br />10-I TO 12
<br />12-I TO 14
<br />14-I TO 16
<br />16-1 TO 18
<br />5/4" DECKING
<br />FLOOR TRU55 PER PLAN
<br />PLAN W/ DOUBLE TRTD J5T5 PER PLAN
<br />1/2" DIAMETER LAG SCREWS
<br />��
<br />W/ 15/32 MAX SHEATHING
<br />30" O.G.
<br />23" O.G.
<br />18" O.G.
<br />15" O.G.
<br />13" O.G.
<br />I I" O.G.
<br />10" O.G.
<br />VERTICAL -END -WEBS IETRTD DECK RIM
<br />1/2" PIAMETER BOLTS W/
<br />36" O.G.
<br />36" O.G.
<br />34" O.G.
<br />29" O.G.
<br />24" O.G.
<br />21" O.G.
<br />19" O.G.
<br />R-21 SPRAY FOAM INSUL.
<br />I/2" HOT -DIPPED
<br />15/32 MAX. SHEATHING
<br />GALVANIZED LAG SCREW OR
<br />ANDWASHERS,
<br />1/2" DIAMETER BOLTS W/ 15/32" MAX
<br />SHEATHING & 1/2" 5TACKED WASHERS (B,H)
<br />ii
<br />36 O.G36
<br />ii O.G.
<br />ii
<br />29 O.G.
<br />i
<br />ii
<br />24 O.G.
<br />i
<br />ii
<br />21 O.G.
<br />i
<br />ii
<br />18 O.G.G.
<br />i
<br />F16"THRU-13OLT
<br />,. 5TA66E13E12
<br />NOTE:
<br />FOR 51: I"=25.4 MM, I FOOT =304.8 MM, I POUND PER SQUARE FOOT = 0,0479 KPA
<br />INSTALL ICE & WATER 5HIELD (MIN. 36" WIDE) BEHIND DECK RIM
<br />A. THE TIP OF THE LAG SCREW SHALL FULLY EXTEND BEYOND THE FLOOR TRU55 RIBBON
<br />PRE DRILL DECK RIM & FILL HOLES W/ 51LICONE
<br />B. THE MAXIMUM GAP BETWEEN THE FACE OF THE LEDGER BOARD & FACE OF THE WALL SHEATHING SHALL BE "
<br />USE LAG SCREWS OR BOLTS TO ATTACH
<br />MINIMUM OF 6 OF FLASHING INSTALLED OVER DECK RIM
<br />C. LED6ER5 SHALL BE FLASHED TO PREVENT WATER FROM CONTACTING THE HOUSE FLOOR TRU55 RIBBON
<br />SILICONE THREE EDGES OF DECK RIM TO ICE &WATER 5HIELD
<br />D. LAG SCREWS AND BOLTS SHALL BE 5TAG6ERED IN ACCORDANCE WITH SECTION R507.2.1
<br />E. DECK LEDGER SHALL BE MINIMUM DEPT TO MATCH JOIST PRESSURE- PER5ERVATIVE- TREATED NO.2 GRADE LUMBER
<br />RIM DETAIL @ D C K
<br />F. EXCLUDED -NO ENGINEERED WOOD PRODUCT RIM U5E0
<br />G. EXCLUDED - NO LAMINATED VENEER PRODUCT RIM U5ED
<br />SECTION VIEW
<br />H. THE MAXIMUM D15TANCE BETWEEN THE FACE OF THE LEDGER BOARD & THE FACE OF THE FLOOR TRU55 RIBBON SHALL BE I"
<br />TABLE R507.2.1
<br />PLACEMENT OF LAG SCREWS & BOLTS IN DECK LEDGER5 & BAND JOISTS
<br />TOP EDGE
<br />BOTTOM EDGE
<br />ENI25
<br />ROW SPACING
<br />FLOOR SHEATHING
<br />NAILING AT 6" MAX.
<br />LEDGER
<br />O.G. TO TRU55 WITH HOLD DOWN OR
<br />2 INCHES (D)
<br />1/4 INCH
<br />2 INCH (15)
<br />1 5/8 INCH (13)
<br />FLOOR TRU55 RIBBON
<br />HOLD DOWN SIMILAR TENSION
<br />3/4 INCH
<br />2 INCH
<br />2 INCH (B)
<br />15/8 INCH (B)
<br />FOR 51: 0=25.4 MM
<br />DEV ICE
<br />V
<br />A. LAG 5GREW5 AND BOLTS SHALL BE 5TA66ERED FROM THE TOP TO THE BOTTOM ALONG THE HORIZONTAL RUN OF THE DECK LEDGER IN
<br />FLOOR DECK J015T
<br />r2/
<br />ACCORDANCE WITH FIGURE R507.2.1(1)
<br />TRU55 PER
<br />PER PLAN
<br />B. MAXIMUM 5 INCHES
<br />PLAN
<br />rA
<br />C. EXCLUDED NO ENGINEERED WOOD PRODUCT RIM U5E12
<br />OPTIONAL MICROLAM
<br />12. THE MINIMUM D15TANCE FROM BOTTOM ROW OF LAG SCREWS OR BOLTS TO THE TOP EDGE OF THE LEDGER SHALL BE IN ACCORDANCE
<br />NAILED TO SIDE OF
<br />WITH FIGURE R507,2.1(1)
<br />I/2" PLYWOOD TRU55
<br />SHEATHING W/
<br />FIGURE R507.2.1 1
<br />DECK CONNECTION NOTES
<br />50L ID BLOCKING
<br />BEHIND
<br />* HOLD DOWN TENSION DEVICE MUST BE INSTALLED
<br />IN NOT LE55 THAN TWO LOCATIONS PER DECK
<br />* EACH DEVICE MUST HAVE AN ALLOWABLE 5TRE55
<br />DESIGN CAPACITY OF NOT LE55 THAN 1,500 POUNDS
<br />R I DETA IL @ DECK
<br />SECTION VIEW FIGURE 507.2.3 MODIFIED
<br />FO FLOOR TRU55
<br />SEE SECTION
<br />SEE SECTION FOR
<br />5UBFLOOR INFO---
<br />2x R IBBON
<br />SPRAY FOAM INSUL.-
<br />R21 MINIMUM
<br />FLOOR TRU55 PER PLAN
<br />1/2" GYP BOARD
<br />SEE SECTION
<br />RIM DETAIL
<br />o z
<br />I
<br />II
<br />I
<br />1�3" MIN. A85 OR PVC OR EQUIVALENT
<br />I
<br />GASTIGHT PIPE (AF103.6.1)
<br />F �
<br />/-PROVIDE SPACE FOR FUTURE
<br />I
<br />INSTALLATION OF A FAN (AF103.8)
<br />* MIN. 24" DIAMETER CENTERED ON
<br />THE AX15 OF THE VENT 5TA6K
<br />PER PLAN L
<br />J * MIN. VERTICAL 1215TANCE 36"
<br />PER PLAN
<br />j' INSTALL LIVE OUTLET IN ATTIC WHERE
<br />I FUT. FAN MAY BE INSTALLED (AF103.12)
<br />lIN
<br />INSTALL LABEL READING (RADON REDUCTION
<br />SYSTEM) ON THE VENT PIPE AT EACH FLOOR
<br />AND IN ACCE55113LE ATTICS (AF103.4.5)
<br />PER PLAN j
<br />PER PLAN ALL PIPE JOINTS AND FITTINGS
<br />TO BE GLUED OR TRANSITION
<br />COUPLINGS
<br />SEAL ALL FLOOR OPENINGS SS
<br />PER PLAN J�
<br />11
<br />11
<br />j I INSTALL LABEL READING (RADON REDUCTION
<br />PER PLAN j SYSTEM) ON THE VENT PIPE AT EACH FLOOR
<br />AND IN A66ESSI13LE ATT165 (AF103.4.5)
<br />I I ALL CONTROL JOINTS, 150LATION JOINTS,
<br />11 CONSTRUCTION JOINTS, AND ANY OTHER
<br />1 I JOINTS IN CONCRETE 5LA135 SHALL BE
<br />SEAL ALL JOINTS 5EALED WITH CAULK OR SEALANT
<br />BETWEEN 5LA13
<br />AND FOUND. WALL
<br />I SEALED SUMP BASKET
<br />I I MIN. 6 MIL OR 3 MIL CROSS
<br />4" PERFORATED DRAIN I 11 I LAMINATED POLY SHALL BE
<br />TILE W/FILTER FABRIC L v J LAPPED 12" AND PLACED BELOW
<br />8"X16" ROCK TRENCH THE SLAB AND ON TOP OF 4" MIN. 5AN12 GAS
<br />(1 "-1 1 /2") PERMEABLE LAYER
<br />PA551VE RADON DETAIL
<br />SCALE: 1/4" = I'-0"
<br />P I LEOGER-\ 1' 1 101 N f 101 101
<br />N LAG SCREW I I LEDGE I I-rLaaK I I TKI1ZD*- 1 1
<br />__--I—LRBOLT __LJSPLICE _L1TRU55LLRIBBON_J_I____
<br />SEE SECTION
<br />SEE SECTION FOR
<br />SU13FLOOR INFO-,
<br />FLOOR
<br />5P
<br />TRUSS
<br />A
<br />FOAM IN3UI,.
<br />PER PLAN
<br />BLOCKING AS
<br />READ. FIRST 3 BAYS
<br />* PROVIDE ADDITIONAL
<br />BLOCKING AT POINT LOADS
<br />RIM DETAIL
<br />* PARALLEL TO FOUNDATION
<br />WALL BLOCKING
<br />A. TABLES & FIGURE HAVE BEEN MODIFIED FROM CODE
<br />BOOK TO REFLECT FLOOR TRU55 CONDITIONS WITH 2X1
<br />RIBBON WITH TREATED 2X10 DECK RIM
<br />SEE SECTION —
<br />SEE SECTION FOR
<br />SU13FLOOR INFO
<br />BLOCKING 13TWN TRU55E5
<br />HEAT RUN ,
<br />1/2" 5HTH'6 CANT, BARRIER,
<br />SEAL PERIMETER, JOINTS, AND
<br />OPEN ING5
<br />FLOOR TRU55 PER PLAN
<br />1/2" GYP BOARD
<br />RIBBON
<br />SEE SECTION
<br />2x RIBBON
<br />SPRAY FOAM INSUL.
<br />R21 MINIMUM
<br />SHEATHING
<br />SOFFIT
<br />R-38 INSULATION MIN.
<br />RIM DETAIL @ CANTILEVER
<br />CEILING DRYWALL TAPED
<br />TO WALL DRYWALL
<br />DRYWALL CAULKED, GLUED,
<br />or 6A5KETED TO TOP PLATE
<br />DRYWALL CAULKED, GLUED,
<br />or GASKETED TO BOTTOM PLATE
<br />BOTTOM PLATE CAULKED or
<br />6A5KETE12 TO SU13FLOOR
<br />SPRAY FOAM INSUL.
<br />R21 MINIMUM
<br />DRYWALL CAULKED, GLUED,
<br />or 6A5KETED TO TOP PLATE
<br />DRYWALL CAULKED, GLUED,
<br />or GASKETED TO BOTTOM PLATE
<br />BOTTOM PLATE CAULKED or
<br />GA51<ETED TO 5U13FLOOR
<br />SPRAY FOAM INSUL.
<br />R21 MINIMUM
<br />EXTERIOR SHEATHING CAULKED,
<br />GLUED, or 6ASKETE12 TO SILL PLATE
<br />TRTD SILL PLATE W/
<br />SILL 5EALER/6ASKET
<br />TAPED OR SEALED JOINT @
<br />EXTERIOR SHEATHING &
<br />FOUNDATION INSULATION
<br />OPTION #
<br />ENVELOPE AIR SEALING
<br />* NOTE: 5HADED COMPONENTS DESIGNATE
<br />AIR FLOW RETARDER SYSTEM
<br />DRUK HOMES
<br />1240 ARBOR ST.
<br />ORONO, MN
<br />PLAN APPROVED FOR PERMIT APPLICATION FOR ADDRESS SHOWN ONLY
<br />DRYWALL CAULKED, GLUED,
<br />or 6ASKETE12 TO TOP PLATE
<br />EXTERIOR SHEATHING CAULKED,
<br />GLUED, or 6A51<ETED TO TOP PLATE
<br />TAPED OR 5EALE12 JOINTS IN
<br />EXTERIOR SHEATHING
<br />EXTERIOR SHEATHING CAULKED,
<br />GLUED, or 6A51<ETED TO BOTTOM PLATE
<br />SPRAY FOAM INSUL.
<br />R21 MINIMUM
<br />EXTERIOR SHEATHING CAULKED,
<br />GLUED, or 6A51KETED TO TOP PLATE
<br />TAPED OR 5EALE12 JOINTS IN
<br />EXTERIOR SHEATHING
<br />EXTERIOR SHEATHING CAULKED,
<br />GLUED, or 6A51<ETED TO BOTTOM PLATE
<br />SPRAY FOAM INSUL.
<br />R21 MINIMUM
<br />EXTERIOR SHEATHING CAULKED,
<br />GLUED, or GASKETED TO SILL PLATE
<br />TRTD SILL PLATE W/
<br />SILL 5EALER/GA5KET
<br />TAPED OR SEALED JOINT @
<br />EXTERIOR SHEATHING &
<br />FOUNDATION INSULATION
<br />OPTION '2
<br />ENVELOPE AIR SEALING
<br />* NOTE: SHADED COMPONENTS DE5I6NATE
<br />AIR FLOW RETARDER SYSTEM
<br />rn 0
<br />�o
<br />Lo Z 0
<br />Ln o o
<br />(nCO
<br />w
<br />o0
<br />a- co
<br />LL
<br />L o
<br />Z @
<br />ZQo°
<br />l!RRJLL�
<br />Vpjz..
<br />X
<br />0
<br />�/'� J LL
<br />F5 O Q
<br />w w 7i
<br />[-- w
<br />0t
<br />w w Z O
<br />U'�-
<br />� ZO
<br />U' (D o
<br />w � CO
<br />zoo
<br />O a- 00
<br />Z LL �
<br />o ro
<br />a Z a �
<br />Qm
<br />Jo 0
<br />m L
<br />w a-
<br />wF
<br />O
<br />o�
<br />x
<br />ao
<br />�z
<br />boa
<br />�
<br />�o
<br />P4
<br />DATE:
<br />7-5-16
<br />REVISIONS:
<br />7-18-16 JP
<br />DRAWN BY:
<br />JP
<br />COMM. NO.
<br />216284
<br />SHEET NO.
<br />P I