Laserfiche WebLink
m <br />(� TRTD. 3-2X10 FL. <br />TRTD. 6X6 WOOD <br />POST ON 12110 1 <br />50NATU13E (TYP.) I <br />DASHED LINE AT I I <br />SHOWS FOUNDATION I �� DECK AEOVE I <br />LINE BELOW I - � I <br />1 n1 1 <br />1 1 <br />511-101, 1 1 <br />261-011 I HOLD 251-101, <br />71-411 1 DOWN 12'-511 <br />w211 F I O 31-10' 6" 61-411 <br />IN 211 I IGA3743 (TYP.) <br />91-1011 <br />0 <br />0 <br />I 61-111 <br />31-4111 21-311 21-911 211 <br />IGA3743 =o <br />1 I SHEATHING. <br />N I CONT. 2 <br />9 1 /211 M.L. <br />2-2X8 <br />psi ' <br />o <br />4 MULL 2X8 5 <br />HOLD <br />UDS @ 1611 O.G. I <br />(TYP.) <br />W I 4211 OF <br />8° POURED I <br />DOWN <br />w <br />�- I 20°X8° <br />GONG. FTG. <br />I I <br />IN6 <br />PROV IDE 50L ID <br />ED <br />@ F 15HE <br />BLOCKING TO ABOVE (TYP.) <br />i i <br />AREAS <br />�I <br />811 OF 611 POURED, FUTURE <br />i ; N <br />FUTURE <br />w <br />6011 OF 8° POURED (VERIFY W/GRADE) I REG, ROOM <br />I I N <br />EEDROOM t4 <br />20°X8° GONG. FTG. I CARPET <br />j <br />CARPET <br />_ _ 3 1 /211 GONG. FLOOR <br />,1 <br />8'-1" CEILING HT. <br />I ISp� <br />I <br />j l <br />9611 OF 8" POURED <br />1 <br />I I FF- <br />20°X8° GONG. FTG. <br />I I <br />I R-5 IN5UL. - <br />IIII <br />IIII <br />I 141-611 <br />31-811 <br />7' IOII <br />IIII 26 <br />- <br />1 <br />II <br />IN12 I I 1811 FLOOR <br />- <br />��, <br />I F3 <br />W I TRU55E5 <br />I I <br />I 4QB1-PASS <br />o p I 9.211 0.6 <br />1 125R0 <br />== =_= <br />I r-3 �E <br />i <br />- <br />1 <br />I I N <br />,�/ I k _-----_-----, <br />II <br />N <br />I <br />1� <br />N 411 <br />7 1_10 a 2 IIII ,4 <br />III <br />C.TILE <br />� II �m I <br />I <br />I I <br />`V <br />-- <br />r----- <br />VANITY <br />- <br />_ <br />I + <br />_-----� <br />�� <br />PROVIDE 501-I12I� <br />I I I I 1L <br />UNEXGAVATED BLOCKING FOUND. <br />I I <br />E <br />I <br />F- <br />L J �� <br />I <br />TD SUBFLOOR (TYP.) 5 ED iN 2$ <br />------- <br />_ <br />-- <br />2��-L - <br />I <br />I su <br />811 OF 6" POURED rt 4- <br />I � I I <br />I ----L <br />I �\ <br />I <br />SHELVES <br />t <br />-STOR., / <br />o <br />I I <br />8811 OF 10" POURS -- <br />20°X8° GONG. FTG. \� <br />MEGH.) <br />I <br />I _ <br />II <br />2- <br />lUN CEILING / <br />v 1 0 <br />1 /211 GYP. BD. @ I RVENI I I �I <br />1811 FLOOR <br />TRU55E5� I <br />R80 <br />= I N <br />N I - <br />WALLS &CEILING I 1 a _ <br />BELOW STAIRS <br />= <br />19.211 O.G o <br />I ' /-m <br />BYFGO� MAX. <br />FIRE bL�K PERIMETER <br />I <br />IIf p z I II � <br />2X6 5TUD5 @ 16" O.C. I �I II 3 <br />j <br />I HI- <br />FF \ <br />I <br />L J II <br />I <br />_ <br />u n 411 OF 6° POURED I II <br />8 OF 6 POURED " " I TREAD5 II <br />_ _ _ _ _ FU <br />I <br />De \ <br />HI-EFF \ <br />I <br />I <br />u 11 20 XS GONG. FTC. I <br />4011 OF 8 POURED I it <br />I <br />WH \ <br />20 XS GONG. FTG. I <br />I r- <br />1 <br />I = <br />FI I I <br />�� - <br />F <br />FOUNA. <br />------------------ <br />IN 2 I 41-311 I1-II°rj <br />��I >�---- <br />8'-0° L-� - <br />--- <br />_ <br />8° OF 611 POURED <br />coT) <br />211 X <br />- <br />o <br />_ <br />8811 OF 10" POURED <br />o _ � <br />B <br />� <br />2011X811 GONG, FTG. <br />3611X3611X1211 <br />N FOUND. <br />= <br />GONG. FTG. 3611X3611X12°---------- -------- <br />- - - - - - - - tjjlo <br />o <br />GONG. FTG. <br />UNEXGAVATED <br />0 <br />811 OF 6° POURED <br />8811 OF 811 POURED o 88" OF 8" POURED <br />IL <br />20°X8° GONG. FTG., 1611X811 GONG. FTG. <br />411 <br />� <br />J <br />—� I ' <br />DRUK HOMES <br />1240 ARBOR ST. <br />ORONO, MN <br />PLAN APPROVED FOR PERMIT APPLICATION FOR ADDRESS SHOWN ONLY <br />FOUNDATION 15 <br />HELD IN FOR <br />INSULATION AS <br />NOTED <br />rn 0 <br />�o <br />�o <br />L z0 <br />Ln oo <br />uo, <br />Z W <br />� o0 <br />a -co <br />w <br />wo <br />z @ <br />ZQO <br />Vpjz.. <br />_X <br />0 <br />� J w <br />O Q <br />w W <br />~ W <br />om <br />z W ~ <br />z �O <br />oz <br />CL WOd <br />QL N �- <br />d <br />0 00�3 <br />FOUNPAT ION PLAN <br />- <br />SCALE: 1 /411_ I1-011rT1 <br />• <br />EXTERIOR DIMENSIONS ARE FROM EXTERIOR OF FOUNDATION <br />WALLS AT FULL BASEMENT AREAS, AND AS NOTED AT <br />Z <br />FRAMED WALLS AT LOOKOUT AND WALKOUT AREAS <br />O <br />N <br />F+1 <br />BASEMENT FINISHED 0 50. FT. <br />BASEMENT UNFINISHED 836 50. FT. <br />0 <br />W <br />ZO <br />WINDOW NOTE5 <br />* INTEGRITY WINDOW5 <br />* BLOR. TO VERIFY ALL WINDOW, DOOR, & OPENING HOR. HT5. <br />N <br />0 w <br />* WINDOW WELLS WITH A VERTICAL DEPTH OF MORE THAN 4411 <br />O <br />MUST BE EQUIPPED WITH AN APPROVED LADDER <br />GUARDRAIL NOTE5 <br />* GUARDRAIL REQUIRED ON OPEN SIDE OF ANY STAIR MORE <br />THAN 3011 ABOVE FLOOR <br />�1 <br />* ALL OPENINGS LESS THAN 411 AT ALL GUARDRAILS <br />51 711 61_011 21_711 DASHED LINE AT <br />FULL BASEMENT <br />FLOOR 5Y5TEM NOTES <br />* ALL FLOORS TO BE L/480 <br />141-211 III-1011 SHOWS SHEATHING <br />* FLOOR TRUSS MANUF. TO VERIFY FRAMING BELOW GRANITE <br />L INE ABOVE <br />261-011 261-011 L <br />TOPS ABOVE <br />FLOOR TRUSS MANUF. TO PROVIDE HEAT SUPPLY & RETURN <br />6HA5E IN TRUSSES <br />521.011 <br />FOUNDATION NOTE5 <br />* 8'-011 POURED FOUNDATION WALLS W/THREE PLATES <br />FOUNDATION WALLS HELD IN FROM 5HEATHING ABOVE AS INDICATED <br />* SILL PLATE OVERHANGS FOUNDATION 1 1/211 MAX. (SEE DETAIL5) <br />* BASEMENT FLOOR RA15EP TO TOP OF WALKOUT STEM WALL <br />* ASSUMED 501L BRG. CAPACITY 2,000 L155. <br />* MASONRY CONTRACTOR TO VER ALL WALL & FOOTING REQUIREMENTS <br />A U <br />AT ALL UNBALANCED BACKFILL LOCATIONS <br />SHEETROCK & INSULATION NOTES <br />* 5HEETROCK ENTIRE CEILING (EXCEPTION 80" MAX @ MECHANIAL) <br />* 1/211 GYP. BD. AT WALLS & CEILING BELOW STAIRS <br />* R-10 EXTERIOR FOUNDATION INSULATION @ FULL 135MT/LOOKOUT <br />* R-5 MIN, R-I I MAX. INTERIOR FOUND. IN5UL. @ FULL 135MT/LOOKOUT <br />DATE: <br />7-5-16 <br />REVISIONS: <br />(FOIL FACED AT ALL UNPROTECTED AREAS) <br />* R-5 EXTERIOR FOUNDATION INSULATION @ WALKOUT <br />7-18-16 JP <br />* R-10 FOUND. IN5UL. IF IN51DE OF WALKOUT FOUND. WALL <br />* NOTE: SEE R402.2.8-EXCEPTION TO REMOVE R-5 INTERIOR <br />INSULATION CALCULATIONS TO BE DONE BY OTHERS <br />FRAM IN6 NOTES <br />* 81-9 1/211 PLATE HT. UNLE55 NOTED OTHERW15E <br />* 2X6 5TU1?5 @ POCKET DOOR WALLS UNLE55 NOTED OTHERWISE <br />* DOUBLE 5TUD5 AT ALL WINDOW & PATIO DOOR HEADER5 <br />UNLE55 NOTED OTHERW15E <br />* PROVIDE 5OLI12 BLOCKING AT ALL POINT LOA125, SUPPORT <br />BEAMS, MICROLAM5, AND GIRDER TRUSSES TO FOUNDATION <br />DRAWN BY: <br />JP <br />SMOKE AND CARBON MONOXIDE DETECTOR5 <br />COMM. NO. <br />* PROVIDE SMOKE DETEGTOR5 IN EVERY BEDROOM AND THE <br />CORRIDOR GIVING ACCESS TO THE BEDROOM, ON EACH FLOOR <br />216284 <br />SHEET NO. <br />INCLUDING THE BASEMENT, AND IN ANY ROOM THAT HAS A <br />GE IL ING HEIGHT MORE THAN 2411 HIGHER THAN A 6ORR IDOR <br />GIVING ACCESS TO THE BEDROOMS. <br />* PROVIDE CARBON MONOXIDE 12ETECTOR5 WITHIN 10'-0" OF ALL <br />BEDROOMS <br />