My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 1379
Orono
>
Resolutions, Ordinances, Proclamations
>
Resolutions
>
Reso 0001-7399
>
Reso 1300 - 1399 (July 27, 1981 - August 9, 1982)
>
Resolution 1379
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2015 12:00:55 PM
Creation date
11/13/2015 12:00:55 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
':.'..��X .. � . . <br /> .- �a � C�t� o� ORONO <br /> • � <br /> : y+�" . , <br /> RESOLUTION OF THE CITY COUNCIL <br /> .. :,-:;.f. NO. �� �c/ .. <br /> ��" . . <br /> • • � 4�-� <br /> ;:;a� � <br /> 8) The repair orders issued by the City on June 22, 1981, <br /> have not been complied with and the septic system was <br /> again discharging to the surface as of March 26, 1982 . <br /> a) The June 22, 1981, Orders required vacating <br /> of all but one dwelling unit on the property <br /> within 60 days so as to limit inflow into the <br /> septic system. All 4 � units have continued <br /> to be occupied almost 1 year after these orders . <br /> b) The June 12, 1981 and June 22, 1981, Orders <br /> required regular pumping of the septic � tank to <br /> . prevent further surface discharge. Since fall <br /> of 1981 the tanks have apparently been pumped <br /> every two weeks but this schedule has not been <br /> frequent enough to eliminate surface discharge <br /> which according to the tennants regularly occurs <br /> before each pumping. In addition, the septic <br /> � tank covers installed in 1980 have been removed , <br /> allowing immediate surface overflowing when the <br /> tanks are full. <br /> c) The June 22, 1981, Orders �required submittal of <br /> a professional site evaluation report to determine <br /> site capabilities and design of a functioning <br /> sewage treatment system. On November 16, 1981, <br /> . Thomas Sche,rber' s attorney submitted to the City <br /> a report dated November 2 , 1981, by Percor, Inc. , <br /> attached to this Resolution as Exhibit A, which <br /> report states in part "it will be necessary to <br /> remove one of the cabins to gain more drainfield <br /> area and also to reduce the number of bedrooms <br /> serving the property" . Thus the existing site <br /> cannot support a functioning on-site sewage <br /> treatment. system for the existing four dwelling <br /> units without reduction in the number of buildings <br /> on the premises and reduction in the amount of <br /> inflow to the system. <br /> d) The June 12, 1981 and June 22, 1981, Orders required <br /> repair or complete replacement of the on-site <br /> sewage treatment system with a fully conforming <br /> system capable of accommodating all sewage flow <br /> generated on the premises, on or before September l, <br /> � 1981. To date there has been no attempt to make <br /> any physical improvement to the septic system on <br /> this property. <br /> Page 3 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.