My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1979-03-07 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
D
>
Devin Lane
>
2320 Devin Lane - 03-117-23-22-0014
>
Septic
>
1979-03-07 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2025 2:18:37 PM
Creation date
9/3/2025 2:12:10 PM
Metadata
Fields
Template:
x Address Old
House Number
2320
Street Name
Devin
Street Type
Lane
Address
2320 Devin Lane
PIN
0311723220014
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITE ?VAi TTATION R�?-ORT <br />;-'OR-�T:3IN's'R & KO , ,; FAN, INC. <br />IN LOT 2, BL,)CK 1, N11RS :;;iY <br />March C, 19,119 <br />As requested , and according to the city of Orono regulations, <br />six percolation tests and three soil borings were taken on March 3-4, <br />1979. <br />Percolation holes were dug to a depth of 42 inches being o <br />inches in diameter. Boles were dug with a Dayton model a?014 C <br />auger. No frost was encountered and styrofoam was placed over the <br />holes overnight to keep the water from freezing. the soil borings <br />were dug with the Dayton auger to a depthof 42 inches, with a 3" <br />bucket type hand auger being used for the remaining depth. <br />The proposed drainfield area is located in the Lester Loan <br />soil series and yielded an average percolation rate of 9.6 min. <br />uer inch. Discoloration of the soils indicates that the water table <br />will be somewhat higher in the spring than the present water table <br />indicates. However, the requirements for a standard drainfield <br />system are still met. <br />For the proposed 3 bedroom house, 570 square feet of soil <br />treatment area is required. If 2 foot wide trenches are used , <br />three 100 foot long trenches are needed. Each should be spaced 6.5 <br />feet minimum center to center making the total width 13 feet. <br />More lines of shorter lengft can also be used. Lines should be <br />constructed to follow the contours. The lot should also be graded <br />to divert rui►off away from the soil treatment area. <br />Two septic tanks are required. yach should be of 10JO gallon <br />capacity. They should be located at least 10 feet from the house. <br />In addition , if the basement is to be served by the sewer, <br />a oump and t)um,>ing tank will be needed to pump the effluent to the <br />higher drainfield area if the house elevation remains as proposed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.