My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4423 North Shore Drive - Building Plans: Residential
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
4423 North Shore Drive - 07-117-23-34-0001
>
Permits/Inspections
>
4423 North Shore Drive - Building Plans: Residential
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2025 2:27:38 AM
Creation date
8/19/2025 4:07:53 PM
Metadata
Fields
Template:
Address
Street Name
North Shore Drive
House Number
4423
Address
4423 North Shore Drive
PIN
07-117-23-34-0001
Address Doc Type
Building Plans: Residential
Section
Permits/Inspections
Retention Effective Date
7/3/2025
Retention
1 Year After Project Complete Date
Protection
Non-Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11/2" <br />FOUND. INSULATION/WATERPROOFING SYSTEM <br />EXTERIOR WALLCONSTRUCTION <br />ANCHOR BOLT <br />POURED CONCRETEFOUNDATION WALL <br />2x8 SILL PLATE w/SILL SEALER <br />1X_ LEDGE <br />GRADE <br />METAL COIL FLASHINGTO COVER INSULATION <br />AT THINSTONE ONLY:2" THK RIGID INSULATION48" DEEP TO PROTECT THINSTONE FROM FROST <br />DRAINAGE MATTO WEEP 8"ABOVE GRADE <br />THINSTONE VENEER <br />2x4 FURRINGw/INSULATIONPER CODE <br />1'-6"30'-9" <br />13'-0" <br />1 1/2"7'-1 1/4"5'-10 3/4"6 1/2"T.O. MAIN LEVEL SUBFLOOR = 100.0' <br />NOTE: <br /> FOUNDATION HEIGHTS T.O. CONCRETE ARE INDICATED IN RELATIONSHIP TO MAIN LEVEL SUBFLOOR(SEE EXTERIOR ELEVATIONS FOR APPROXIMATE STEP LOCATIONS) <br />VERIFY DEPTH OF FOOTINGS <br />TO UNDISTURBED SOIL & <br />STEP FOOTING LOCATIONS <br />12'14'16' <br />GRAPHIC SCALE <br />4'0'2'6'8'10'1'-1 1/2"9'-10"12'-9"4'-6"35'-10 1/2"1 1/2"17'-2"6'-6"7'-4"95'-2 1/2"3'-0"23'-0"1 1/2"1'-11 1/4"21'-0 3/4"20'-9"13'-0" <br />82'-10 1/2"7'-7"6'-7 1/2"9'-0"19'-10 1/2"7'-4"7'-0"50'-5"2'-6"25'-9"7'-6"3'-0"11'-10 1/2"19'-6"12'-9" <br />46'-7 1/2"1'-1 1/2"11'-1 1/2"35'-10 1/2"2'-6"4'-8 1/2"16'-4"9 1/2"4'-8 1/2" <br />1'-3"2'-6"10"25'-9"7'-5 1/2"7'-10"4'-10 1/2"1 1/4"8'-6 1/4"7'-9 1/4"8'-7 3/4"9'-0"2 3/4"19'-7 3/4"25'-1 1/4"12'-3 1/4"14'-9 3/4"14'-6 3/4" <br />25'-1 1/4"8'-5"2'-11"11 1/4"29'-4 1/2" <br />40'-4 1/2" <br />9 1/2" <br />17'-11 1/2"4'-0"3'-0" <br />33'-2 1/2"3'-9 1/2"2'-10"TYP. TOP CHD BRG WALL <br />w/4" EXTERIOR SLAB LEDGE <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. WALK-OUT FROST WALL <br />w/ 2" INTERIOR SLAB LEDGE <br />7½" POURED CONC. WALL <br />4'-0" TALL <br />TYP. NON-BEARING <br />LOOK-OUT FROST WALL <br />7½" POURED CONC. WALL <br />5'-6" TALL <br />TYP. GARAGE WALL <br />w/ 4" PLANK LEDGE <br />9½" POURED CONC. WALL <br />15'-0" TALL <br />FULL HEIGHT FROST WALL <br />7½" POURED CONC. WALL <br />10'-4" TALL <br />9½" POURED CONC. WALL <br />3'-2 1/2" TALL <br />7½" POURED CONC. WALL <br />14'-6" TALL <br />TYPICAL INTERIOR BEARING <br />WALLS T.O. FTG = 88.56' <br />w/ 1 COURSE CMU <br />STEP <br />FTG <br />STEP <br />FTG <br />TYP. NON-BEARING <br />LOOK-OUT FROST WALL <br />7½" POURED CONC. WALL <br />5'-6" TALL <br />TYP. TOP CHD BRG WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. NON-BEARING WALL <br />9½" POURED CONC. WALL <br />9'-9½" TALL <br />TYP. NON-BEARING WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. TOP CHD BRG WALL <br />w/4"SLAB LEDGE <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />STEP <br />FTG <br />STEP <br />FTG <br />STEP <br />FTG <br />STEP <br />FTG <br />TYP. NON-BEARING WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. TOP CHD BRG WALL <br />w/4"PLANK LEDGE <br />9½" POURED CONC. WALL <br />15'-0" TALL <br />TYP. GARAGE WALL <br />w/ 4" PLANK LEDGE <br />9½" POURED CONC. WALL <br />15'-0" TALL <br />TYP. TOP CHD BRG WALL <br />9½" POURED CONC. WALL <br />15'-0" TALL <br />TYP. NON-BEARING WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. TOP CHD BRG WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. TOP CHD BRG WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. NON-BEARING WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. NON-BEARING WALL <br />w/4" EXTERIOR SLAB LEDGE <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. NON-BEARING WALL <br />w/4" EXTERIOR SLAB LEDGE <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. NON-BEARING WALL <br />w/4" EXTERIOR SLAB LEDGE <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. TOP CHD BRG WALL <br />w/4" EXTERIOR SLAB LEDGE <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. TOP CHD BRG WALL <br />w/4" EXTERIOR SLAB LEDGE <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />TYP. NON-BEARING WALL <br />9½" POURED CONC. WALL <br />10'-9½" TALL <br />7½" POURED CONC. WALL <br />14'-6" TALL <br />BEAM POCKET <br />BEAM POCKET <br />BEAM POCKET <br />STEP <br />FTG <br />FOUNDATION PLAN <br />TYP. 3½" THK SLAB <br />ELEV = 88.56' <br />4" THK SLAB <br />ELEV = 87.56' <br />4" THK SLAB <br />ELEV = 99.33' <br />3½" THK SLAB <br />DROPPED 1½" <br />ELEV = 88.44' <br />2 <br />A7 <br />2 <br />A7 <br />4 <br />A7 <br />4 <br />A7 <br />3 <br />A7 <br />3 <br />A7 <br />1 <br />A8 <br />1 <br />A8 <br />2 <br />A8 <br />2 <br />A8 <br />3 <br />A8 <br />1 <br />A7 <br />1 <br />A7 <br />11/2"6"MIN.51/4"GRADE <br />FOUND. INSULATION/WATERPROOFING SYSTEM <br />EXTERIOR WALLCONSTRUCTION <br />ANCHOR BOLT <br />POURED CONCRETEFOUNDATION WALL <br />2x8 TRTD SILLw/SILL SEALER <br />SPRAYED INSULATION-SEE SPEC. <br />TOP CHORD BEARINGMFR. FLOOR TRUSSBLOCKING BY SUPPLIER M.L. SUBFLOOR <br />T.O. CONC. <br />AT THINSTONE ONLY:2" THK RIGID INSULATIONTO PROTECT FROM FROST <br />AT THINSTONE VENEER-DRAINAGE MAT TO WEEP 8" ABOVE GRADE <br />AT SIDING - METAL COIL FLASHING TO COVER INSUL./ DAMPPROOF SYSTEM <br />AT STUCCO - FINISHTO GRADE w/WEEP SCREED <br />2x4 FURRINGw/INSULATIONPER CODE <br />11/2"51/4"FOUND. INSULATION/WATERPROOFING SYSTEM <br />MTL. FLASHING <br />CONC. SLAB SLOPED 1/8" PER FT AT UNCOVERED LOC. <br />EXTERIOR WALLCONSTRUCTION <br />ANCHOR BOLT <br />POURED CONCRETEFOUNDATION WALL <br />2x8 TRTD SILLw/SILL SEALER <br />SPRAYED INSULATION-SEE SPEC. <br />TOP CHORD BEARINGMFR. FLOOR TRUSSBLOCKING BY SUPPLIER <br />THINSET STONE <br />AT STUCCO - FINISHTO GRADE w/WEEP SCREED <br />AT THINSTONE VENEER-DRAINAGE MAT TO WEEP ABOVE EXT. SLAB <br />2x4 FURRINGw/INSULATIONPER CODE <br />2x6 TRTD SILL w/SEALER <br />ANCHOR BOLT <br />EXTERIOR WALLCONSTRUCTION <br />T.O. CONCRETE <br />2" RIGID INSULATION <br />CONC. SLAB <br />THERMAL BREAK DRAINAGE MATTO WEEP 8"ABOVE GRADE <br />SMOOTH MDO or <br />THINSTONE VENEER <br />THINSET STONE <br />CONC. SLAB SLOPED 1/8" PER FT AT UNCOVERED LOC. <br />DRAIN TILE <br />11/2"1'-0"51/4"EXTERIOR WALLCONSTRUCTION <br />ANCHOR BOLT <br />POURED CONCRETEFOUNDATION WALL <br />2x8 SILL PLATE w/SILL SEALER <br />T.O. CONCRETE <br />M.L. SUBFLOOR <br />GARAGE FLOOR CONSTRUCTION <br />CAULK JOINT @ <br />PERIMETER <br />THERMAL BREAK <br />FOUND. INSULATION/WATERPROOFING SYSTEM <br />GRADE <br />AT SIDING - METAL COIL FLASHING TO COVER INSUL./ DAMPPROOF SYSTEM <br />AT STUCCO - FINISHTO GRADE w/WEEP SCREED <br />1'-0"M.L. SUBFLOOR <br />SPRAYED INSULATION-SEE SPEC. <br />FIRE-RATED WALL <br />GARAGE PLANK FLOOR CONST. <br />BTM CHORD BEARINGMFR. FLOOR TRUS 1'-43/4"51/4"1'-0"FOUND. INSULATION/WATERPROOFING SYSTEM <br />POURED CONCRETEFOUNDATION WALL <br />TYP. T.O. CONCRETE <br />M.L. SUBFLOOR <br />GARAGE FLOOR CONSTRUCTION <br />1" 40 PSI R-5 INSULATION BETWEEN APRON SLAB AND FOUNDATION WALL, INTERIOR SLAB, AND SIDE STEM WALLS <br />EXCALIBUR ALUMINUM THRESHOLD w/ BEADS OF SEALANT AT GROOVES ALONG ENTIRE LENGTH OF THRESHOLD - INSTALL ANCHORS PER MFR. RECOMMENDATION <br />CAULK JOINT @ PERIMETER <br />CONCRETE APRON <br />T.O. CONCRETE <br />THERMAL BREAK <br />1'-0"51/4"1'-41/2"POURED CONCRETEFOUNDATION WALL <br />T.O. CONCRETE <br />CONC. SLAB <br />THERMAL BREAK <br />GRADE <br />CONCRETE APRON <br />L.L. T.O. CONCRETE/SLAB <br />1'-0"6"MIN.51/4"1'-41/2"POURED CONCRETEFOUNDATION WALL <br />2x6 TRTD SILL w/SEALER <br />ANCHOR BOLT <br />EXTERIOR WALLCONSTRUCTION <br />T.O. CONCRETE <br />CONC. SLAB <br />THERMAL BREAK <br />L.L. T.O. CONCRETE/SLAB <br />GRADE <br />AT SIDING - METAL COIL FLASHING TO COVER INSUL./ DAMPPROOF SYSTEM <br />2x6 TRTD SILL w/SEALER <br />ANCHOR BOLT <br />T.O. CONCRETE/SLAB <br />2" RIGID INSULATION <br />CONC. SLAB <br />THERMAL BREAK <br />DRAIN TILE <br />CONC. SLAB <br />THERMAL BREAK <br />0'2' <br />GRAPHIC SCALE <br />1'369 3 6 9 3 6 9 3 6 9 3' <br />2 T.C. BRG SILL DETAIL <br />3 T.C. BRG SILL w/SLAB DETAIL <br />8 LOOKOUT SILL DETAIL <br />7 WALKOUT SILL DETAIL <br />5 TYPCIAL GARAGE PLAN DETAIL <br />6 GARAGE PLAN TO HOUSE <br />4 GARAGE PLAN/APRON @ O.H. DOOR <br />9 TYP. L.L. GARAGE SLAB @O.H. DOOR <br />10 TYP. L.L. GARAGE SLAB DETAIL11L.L. GARAGE TO BASEMENT <br />SHEET <br />A0 <br />952-544-3844 <br />18318 Minnetonka Blvd <br />Deephaven, MN 55391 <br />Copyright 2024 <br />SAGA HILL <br />RESIDENCE <br />4423 N. SHORE DR. <br />ORONO, MN 55364 <br />952-476-2679 <br />18352 Minnetonka Blvd <br />Deephaven, MN 55391 <br />PERMIT SET <br />08 APRIL 2024 <br />Reviewed for Code Compliance <br />Nicole Post <br />RPS24-000045 <br />5-8-24 <br />Additional permits <br />required: <br />Plumbing <br />Mechanical <br />Electrical <br />Stamped and <br />approved plans must <br />be on site for the <br />duration of the project <br />and all inspections. <br />To schedule inspections call: <br /> 952-249-4613 <br />Please have the permit number <br />and street address ready at <br />time of call. <br />Please plan accordingly. The <br />City will not issue a Temporary <br />Certificate of Occupancy (Temp <br />CO) for new homes during the <br />growing season from May 1st to <br />November 1st. Issuance of a <br />Certificate of Occupancy requires <br />all permits associated with the <br />project to be finaled and an <br />as-built survey approved by the <br />City. If vegetation is not fully <br />established at the time of CO <br />issuance, the erosion control <br />escrow will continue to be held. <br />See Engineering
The URL can be used to link to this page
Your browser does not support the video tag.