Laserfiche WebLink
ON SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />ORONO <br />tt ADDRESS <br />On the North Shore of <br />Lake Minnetonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473-7357 <br />/).U> <br />PERMIT NO.'S.DATES CONTRACTORS <br />City Ordifwnc* No. 210 r«quir*t that each on-«ite eawage treatment tyitem in Orono be inspected on a regular basis. 1 he on-site sewage <br />treatment system at the above addren has been inspected and appears to fail into the category checked below. <br />(This is □ an existirtg system □ new construction) <br />I I 1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating <br />properly. <br />^^2 "O’ ■" current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no maior <br />upgrading of the system is required at this time. <br />rn 3 "O’ current City standards in many respects relating to design, construction, or location. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br />this time. <br />^ System may or may not meet current City standards for design, construction or location, but is (ailing to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION | (2| Checked items may require your action) <br />Tank inspection indicates: <br />□ Pumpout not needed at this time. <br />O Solids accumulation in tanks indicates they should be pump­ <br />ed out this year to help prevent future problems. <br />□ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as pouible. <br />□ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />O Inspection risers missing—tanks could not be inspected. <br />Inspection risers (4" die. pipe) must be iratuiled in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the lest three veers, they should be pumped out now. <br />J8l Inspection pipe is located directly over tank beffle. (Does not <br />^give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Drainfield inspection indicates: <br />pi Drainfield it dry, no surfacirtg evident. <br />□ Some evidence of surfacing, not critical yet. <br />Q Drainfield is saturated and visibly dischargirtg untreated <br />effluent to the surface. This condition may require replace­ <br />ment or addition to drainfield. Contact the City Inspector <br />imntediately. Repairs must be completed within 90 days. <br />O Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS: <br />Limitirtg Site Factors <br />□ Slope <br />□ Soil <br />□ High water table <br />AT Lot sire <br />□ Lake, wetland, or stream <br />□ Drainage <br />COMMENTS <br />Potential for System Failure <br />(depends on soil types, water <br />table, and system condition) <br />□ Low <br />8 Medium <br />B High <br />D System is causing visible <br />Site Capabilities for <br />Future Expansion <br />n Adequate <br />B Fair <br />BPoor <br />□ Inadequate <br />?lf- rtc<7fds -fanks. <LuiJ Ao I <br />iJcvTt ix-f pAnpp/:f T-gKT ' ^ <br />I <br />Date of Inspection V^tic System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy <br />of the system under current conditions based on the available information. <br />This report must be kept on the premises with system location and pumping records <br />WHITE COPY / Inspector s File GOLD COPY / Homeowner