My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1990-06-18 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
D
>
Dakota Avenue
>
908 Dakota Avenue - 26-118-23-33-0022
>
Septic
>
1990-06-18 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 11:13:53 AM
Creation date
8/6/2025 11:10:26 AM
Metadata
Fields
Template:
x Address Old
House Number
908
Street Name
Dakota
Street Type
Avenue
Address
908 Dakota Avenue
PIN
26-118-2333-0022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ON-SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />ORONO <br />PERMIT NO.'S. -------- DATES ----5Z<32l^ <br />OWNER ADDRESS <br />On the North Shore of <br />Lake Minnetonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay. MN 55323 <br />473-7357 <br />f)rjL-^ 4i^.. <br />CONTRACTORS Bnss, <br />City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site setMage <br />treatment system at the above address has been inspected and appears to fall into the category checked beiow. <br />(This is □ an existing system □ new construction) <br />Meeu or exceeds current City standards in all respecu relating to design, construction, and location. Appears to be operating <br />properly. <br />Does not meet all current City standards for new construction <1978 Code) but in most respects appears to be dMigned. <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgradirsg of the system is required at this time. <br />Does not meet current City standards m many respects relating to design, construction, or location. Appears to be operating <br />adequataly at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br />this time. <br />System may or ntay not meet current City standards for design, construction or location, but is failing to properly treat -nd <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and :ite plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />JSli <br />□ 2 <br />□ 3 <br />□ 4 <br />SYSTEM CONDITION | Q| Checked items may require your action) <br />Tank inspection irtdicates: <br />□ Pumpout rtot rteeded at this time. <br />□ Solids accumulation in tanks indicates they should be pump <br />ed out this year to help prevent future problems. <br />D Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />G System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />O Inspection risers miMing—tanks could not be inspected. <br />Inspection risers (4’* die. pipe) must be installed in each tank <br />at rtext pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />Inspection pipe is located directly over tank oaffle. (Does rsot <br />^give accurate measurement of solids accumulation.) If tanks <br />o^^ave not been pumped out within the last three years, they <br />should be pumped out now. <br />Drainfield inspection indicates: <br />& Drainfield is dry, no surfacing evident. <br />□ Some evidence of surfacing, not critical yet. <br />□ Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace <br />ment or additions to drainfield. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />□ Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS <br />Limiting Site Factors <br />□ Slopa <br />O Soil <br />□ High watar table <br />□ Lot size <br />□ Lake, wetland, or stream <br />□ Drainage <br />Potential for System Failure <br />(depends on soil types, water <br />table, and system condition) <br />□ Low <br />□ Medium <br />□ High <br />□ System is causirtg visible <br />Site Capabilities for <br />Future Expansion <br />□ Adequate <br />□ Fair <br />□ Poor <br />□ Inadequate <br />COMMENTS ^ pkfup tj. <br />' ___ _—---------------------------- <br />Date of Inspection tic System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy <br />of the system under current conditions based on the availaWe information. <br />This report must be kept on the premises witt^ system location and pumping records. <br />WHITE COPY / Inspector’s File GOLD COPY / Homeowner
The URL can be used to link to this page
Your browser does not support the video tag.