PUBLIC PROTECTION
<br />(3) If still unresolved, the health authority
<br />shall take into consideration all informa-
<br />tion and opinions rendered and make a
<br />final judgment. The health authority
<br />shall render findings of fact, conclusions
<br />of law, and findings setting forth the
<br />reasons for any final decisions they render.
<br />(c) Upon resolution of a dispute, amendments
<br />to initial disputed documents containing the
<br />resolution shall be made and submitted to the
<br />health authority and all other parties involved.
<br />(Code 2003, § 58-55; Ord. No. 212(3rd series),
<br />§ 1, 8-13-2018)
<br />Division 3. Construction Inspections
<br />Sec. 5.24.310. Requirements.
<br />Compliance inspections shall be conducted by
<br />the health authority anytime an SSTS is installed,
<br />replaced, abandoned, altered, repaired,
<br />rejuvenated, or extended. The installation and
<br />construction of the SSTS shall be in accordance
<br />with the permit requirements and application
<br />design. If any SSTS component is covered before
<br />being inspected by the health authority, it shall
<br />be uncovered if so ordered by the health author-
<br />ity. Proposals to alter the permitted construction
<br />shall be reviewed and the proposed change
<br />accepted by the health authority prior to construc-
<br />tion. Inspections shall be conducted at least once
<br />during the construction that is prior to covering
<br />of the ISTS to assure that the system has been
<br />constructed per the submitted and approved
<br />design.
<br />(Code 2003, § 58-56; Ord. No. 212(3rd series),
<br />§ 1, 8-13-2018)
<br />Sec. 5.24.320. Inspector.
<br />Any time an SSTS is installed, replaced,
<br />abandoned, altered, repaired, rejuvenated, or
<br />extended, inspections shall be conducted by the
<br />health authority.
<br />(Code 2003, § 58-57; Ord. No. 212(3rd series),
<br />§ 1, 8-13-2018; Ord. No. 292(3rd series), § 1,
<br />2-26-2024; Ord. No. 298(3rd series), § 2, 3-11-
<br />2024)
<br />§ 5.24.370
<br />Sec. 5.24.340. Request for inspection.
<br />It shall be the duty of the permittee to notify
<br />the health authority of the date and time the
<br />inspection is requested at least 24 hours (exclud-
<br />ing weekend days and holidays) preceding the
<br />requested inspection time. If the permitee provides
<br />proper notice as described above and the health
<br />authority does not appear for an inspection
<br />within two hours after the time scheduled, the
<br />permitee may complete the installation and submit
<br />an as -built for the system.
<br />(Code 2003, § 58-58; Ord. No. 212(3rd series),
<br />§ 1, 8-13-2018)
<br />Sec. 5.24.350. Access to premises and
<br />records.
<br />Upon the request of the health authority, the
<br />applicant, owner, permittee or any other person
<br />shall allow access at any reasonable time to the
<br />affected premises as well as any related records,
<br />for the purposes of regulating and enforcing this
<br />article. If entry is refused, the health authority
<br />shall have recourse to the remedies provided by
<br />law to secure entry. No person shall hinder or
<br />otherwise interfere with the health authority in
<br />the performance of their duties and responsibili-
<br />ties pursuant to the enforcement of this article.
<br />Refusal to allow reasonable access to the health
<br />authority shall be deemed a separate and distinct
<br />offense, whether or not any other specific viola-
<br />tions are cited.
<br />(Code 2003, § 58-59; Ord. No. 212(3rd series),
<br />§ 1, 8-13-2018)
<br />Sec. 5.24.360. Stop work orders
<br />Whenever any SSTS work is being done
<br />contrary to the provisions of this article, the
<br />health authority may order the work stopped by
<br />verbal or written notice served upon the installer
<br />or the owner of the land. All installation and
<br />construction shall cease and desist until
<br />subsequent authorization to proceed is received
<br />from the health authority.
<br />(Code 2003, § 58-60; Ord. No. 212(3rd series),
<br />§ 1, 8-13-2018)
<br />Sec. 5.24.370. As-builts.
<br />As-builts shall be submitted to the health
<br />authority within five working days of completion
<br />CD5:37
<br />
|