Laserfiche WebLink
Owner: L u 5— <br />CITY of ORON� <br />Municipal Offices <br />Street Address: <br />2750 Kelley Parkway <br />Orono MN 55356 <br />Mailing Address: <br />P.O. Box 66 <br />Crystal Bay, MN 55323.0066 <br />Address: 258 Cygnet P1. <br />Permit M's: 5826, 2864 Dates: 11/26/79, 9/22/71 Contractors: Widmer Bros., Sullivan <br />(This is [ I an existing system ( I new construction). <br />SYSTEM COMPLIANCE (1-3): 3 <br />1 Code System: Meets or exceeds current City standards in all respects relating to design, <br />construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />codes and is functioning properly. <br />Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the current <br />input; and any system with less than three feet of vertical separation between the bottcr,, <br />of the drainfield and the saturated soil level. <br />(The saturated soil level ( has or ( ) has not been identified at this time. If the <br />saturated soil level has not een identified, this classification is subject to revision.) <br />TANK CONDITION (5-9): 9 <br />5 Pumpout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been pumped out <br />within three years, they should be pumped out and risers installed now. <br />Inspection pipe is located over tank baffle -can not measure solids accumulation. If tanks <br />have not been pumped out within three years, they should be pumped out now. <br />(During the last septic tank Maintenance Pumpout the tanks [ ) were or (x) were not confirmed <br />to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br />watertight, this classification is subject to revision.) <br />Ri�kINFIELD CONDITION (11-14): 11 <br />1 Drainfield is dry, no surfacing evident. <br />2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): medium <br />COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br />were performed to verify a 3 foot separation between the drainfield and the seasonal water <br />table. The separation is 0 feet and the system is non -compliant. Connection to municipal <br />sewer is required by 3/24/98. <br />?:.-K <br />Date of Inspection Sept System finspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Tekpbooe (612) 473-73S7 a FAX 4734510 <br />