All IniWtaUont mutt comply wHh ■« tppllcrtl. .Itcl^ltnd codot. Including but not llmittd to, tho <br />MotkmolEloctrlctl Cod#: loctl. regional ind/orttatt plumbing codot. t^ 00 Y 1 2 3 4 5 & 20 <br />TYPICAL SUMP (DEWATCRINO) IN8TALLATI0M <br />DIAGRAM A <br />TURN <br />OFF' <br />local electrical requirements. <br />2) ‘Install a proper HiLo EZ Check (combination union and check <br />valve) preferably just above the basin to allow easy removal of <br />tho pump for cleaning or repair. See 3) below. <br />3) “When a HILo EZ Check (check valve and union) is installed <br />with a LoBoy 3. drill a 3/16" hole in tho discharge pipe oven with <br />tho top of tho pump. The hole must be below the basin cover. <br />4) All installations require a proper basin cover to prevent debris <br />from falling Into tho basin and to minimize accidental injury. <br />5) Securely tape or clamp power cord to discharge pipe clear of tho <br />float mechanism. <br />•) Minimum 18" diameter x 24" deep basin. <br />7) Use a full size discharge pipe. <br />S) ‘“Level pump in vertical position. Float mechanism must be <br />clear of sides of basin. <br />9) Install blocks or bricks under pump to provide a settling basin. <br />10) Clean basin free of debris after installation. <br />11) Operate switch by running water into pit. Refer to diagram for <br />"ON" and “OFF levels. <br />‘ Note: Splash (vent) hole leakage adjacent to the discharge pipe Is <br />designed and necessary for proper operation for use with check <br />valve. <br />“Note; It is not necessary to drill a vent hole when installing a <br />LoBoy 1.2,4 or 20 as these units do not require a vent hole. <br />“‘Check specific control installation instruction for other type <br />control usage. <br />in*. <br />DIAGRAM B <br />TO LOW PflESSUnE <br />SYSTEM. MOUND <br />SYSTEM. SAND <br />FILTER. LEACHINO <br />FIELD, OR OTHER <br />ON SITE DISPOSAL <br />i. <br />SEPTIC TANK effluent PIT <br />LO BOY 1, 2, 3, & 4 <br />. JYPICAL EFFLUENT INSTALLATION <br />1) Electrical wiring and protection must be in accordance with <br />National Electrical Code and any other applicable state and <br />local electrical requirements. <br />2) All installations require a proper basin cover to prevent debris <br />from falling into basin, and to minimize accidental injury. <br />3) Wire pump to power through a watertight junction box or <br />watertight splice. NOTE: Watertight enclosure is a must in damp <br />areas. <br />4) Use full-size discharge pipe. <br />5) ‘When required, install a proper HiLo EZ Check (combination <br />union and check valve) preferably just below the basin cover to <br />allow easy removal of the pump for cleaning or repair. See 6) <br />below. <br />6) “When a HiLo EZ Check (check valve and union) is installed <br />with a LoBoy 3. drill a 3/16" dia. vent hole In the discharge pipe <br />even with the top of the pump. The hole must be below the basin <br />cover. <br />7) Securely tape or clamp power cord to discharge pipe clear of tho <br />float mechanism. <br />6) “‘Level pump in vertical position. Float mechanism must b.. <br />clear of sides of basin. <br />9) Install blocks or bricks under pump to provide a settling basin. <br />10) Clean basin free of debris after installation. <br />11/ Operate switch by running water into pit. Refer to diagram for <br />"ON" and "OFF" level. <br />•NOTE: Splash (vent) hole leakage adjacent to the discharge pipe <br />is designed and necessary for proper operation for use with a <br />check valve. <br />“NOTE. It is not necessary to drill a vent hole when installing a <br />LoBoy 1,2. or 4 os these units do not require a vent hole. <br />‘“Check specific control installation instruction for other type <br />control usage.