1983-12-29 Letter, Proposed Design Meets Code-2Pgs
Orono
>
Property Files
>
Street Address
>
C
>
Cygnet Place
>
220 Cygnet Place - 04-117-23-23-0014
>
Septic
>
1983-12-29 Letter, Proposed Design Meets Code-2Pgs
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/16/2025 8:47:00 AM
Creation date
7/16/2025 8:45:03 AM
Metadata
Fields
Template:
x Address Old
House Number
220
Street Name
Cygnet
Street Type
Place
Address
220 Cygnet Place
PIN
0411723230014
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'1 lephone -173-7357 <br />CITY of ORONO <br />}lost Office H(jx 669Crystal Hay, Minnesota 553230Municipal Offices <br />On the North Shure of Lake Minnetonka <br />December 29, 1983 <br />Mr. Dale Zoerb <br />A-1 Quality Construction Company <br />2202 Rockstone Lane <br />Minneapolis, Minnesota 55112 <br />Re: Robert Provo Septic System Repair Proposal <br />Dear Mr. Zoerb: <br />Thank you for submitting the Robert Provo septic system site <br />evaluation and design. The proposal appears to meet Orono code <br />requirements in most respects; the following items should be noted: <br />1) New mound is to be placed over old drainfield. All existing <br />trench drainfield, which extends outside the perimeter of the <br />mound, must be removed or turned over and mixed to eliminate <br />the possibility of seepage from mound area into trenches acting <br />as a conduit to the surface. <br />l) Size of pump chamber must allow 150/gal.BR reserve capacity, not <br />75 gal./BR as designed (Orono code requirement). Based on 5 BR's <br />as proposal indicates, reserve capacity of 750 gallons is required. <br />This normally requires use of a 1000 gallon pump tank. <br />3) The existing tanks are presumably 1000 and 600 gallons respectively, <br />based on information supplied by Widmer Bros., Inc. dated December <br />13, 1969. These tanks will be suitable foi continued use only <br />if they have solid concrete bottoms and are reasonably free from <br />groundwater infiltration. It is impossible for me to make a <br />final determination whether the existing tanks need to be replaced <br />until they are opened up. I suggest that you have the system bid <br />both with and without replacement precast tanks. Note, that <br />minimum tank sizes required are 1000 and 750 gallons respectively <br />(see attached Mound System Construction` flyer). <br />