1977-04-29 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
C
>
Cygnet Place
>
190 Cygnet Place - 04-117-23-22-0021
>
Septic
>
1977-04-29 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2025 11:30:55 AM
Creation date
7/10/2025 11:26:43 AM
Metadata
Fields
Template:
x Address Old
House Number
190
Street Name
Cygnet
Street Type
Place
Address
190 Cygnet Street
PIN
0411723220021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Nw <br />Van Eeckhout Building Company <br />1055 East Wayzata Boulevard <br />Wayzata, Minnesota 55391 <br />Attention: Mr. Jerry Finnamore <br />SOIL TESTING SERVICES OF MINNESOTA, INC. <br />2405 ANNAPOLIS LANE SUITE 280 <br />MINNEAPOLIS, MINNESOTA 55441 612-559-1900 <br />August 15, 1977 <br />STS Job No. 91002 <br />Re: Soil Percolation Test at 190 Cygnet Place, Orono, Minnesota. <br />Gentlemen: <br />As directed by your authorization of August 10, 1977, we have completed the <br />soil percolation test at the above referenced property. Six (6) soil percolation <br />test locations were augered to a depth of 3 feet deep on August 12, and tested <br />on August 13, 1977, in accordance with the methods designated by the Minnesota <br />Department of Health, 1971. <br />The attached iog sheet indicates the observed percolation rates at each of the <br />test holes (P-7 through P-12). The observed percolation rates at each of the test <br />holes was within the maximum allowable rate of 60 minutes per inch, as recommended <br />by the Minnesota Department of Health. Based on these observations, the installation <br />of an individual soil absorption system will be acceptable in the area tested. <br />In addition to the above percolation test holes, a single boring was drilled to <br />a depth of 6.5 feet below the existinq ground surface to determine if the water table <br />is less than that depth. According to the readings obtained, it is our opinion ._hat <br />the level o. the ground water at the time of the testing was below that depth. <br />William C. Kwasny, P.E. <br />John P. Gnaedinger, P.E <br />Clyde N. Baker, P.E. <br />James H. Overtoom, P.E. <br />R. Eric Zimmerman, PhD., P.E <br />R W Weinfurter, P.E <br />CHICAGO, PEORIA, ILLINOIS a WASHINGTON, D.C. a CEDAR RAPIDS-IOWA CITY, a Engineering Analysis/Reports <br />DAVENPORT, DES MOINES, IOWA a WICHITA, KANSAS a BAY CITY, DETROIT, GRAND a Construction Quality Control <br />RAPIDS, MARQUETTE, MICHIGAN a MINNEAPOLIS, VIF..GINIA, MINNESOTA a ST. LOUIS, a Foundation Borings and Testing <br />MISSOURI a FAIRFAX, VIRGINIA a GREEN BAY, MILWAUKEE, WAUSAU, WISCONSIN a Environmental Testingand <br />MADRID, SPAIN a BANG OK. THAILAND Evaluation <br />
The URL can be used to link to this page
Your browser does not support the video tag.