Laserfiche WebLink
ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />On the North Shore of <br />Lake Minnetonka <br />CITY POST OFFICE BOX 66 <br />OF 1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />ORONO 473-7357 <br />OWNER C_DLJA1I?L1 C. 812r h-)N =_ADDRESS ,135 1C--V&A)9=7- ,p44GE <br />PHONE PERMIT NO'S. 332/ DATES- q -210- 22 <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. <br />The on -site sewage treatment system at the above address has been inspected and appears to fall into the category checked <br />below: <br />Meets or exceeds current city standards in all respects relating to Jesign, construction, and location. Appears <br />to be operating properly. <br />❑ Does not meet current city standards in some respects relating to design, construction, or location. Appears <br />to be operating properly. <br />Does not meet current city standards in many respects relating to design, construction, or location. Appears <br />to be operating adequately. <br />❑ Does not meet current city standards of design, construction or location, is being overused, or is failing to <br />properly treat and dispose of the current input and is therefore endangering a water supply, is a source of <br />pollution to surface or groundwaters, is creating a safety hazard, or is otherwise creating a public nuisance. <br />Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- <br />quired. In all cases a design a,,d site plan must be submitted for review. Your contractor must obtain a permit <br />before work is started. <br />WORK REQUIRED: <br />❑ Septic tanks must be pumped within 48 hours. <br />❑ Drainfield must be repaired or replaced within 90 days. <br />Inspection riser (4" diam. pipe) must be installed in each tank. <br />❑ Tank inspection indicates maintenance pumpout is needed as soon as possible. City ordinance requires that <br />tanks be pumped out every three years. <br />SITE CHARACTERISTICS: <br />Limiting Site Factors <br />❑ Slope <br />❑ Soil <br />igh water table <br />Lot size .to3 AL vrcY '} <br />ake, wetland, or strjam <br />❑Drainage <br />Potential for System Failure <br />(depends on soil types, water <br />table, and system condition) <br />❑ Low <br />❑ Medium <br />High <br />❑ System is causing visible <br />surface discharge. <br />Site Capabilities for <br />Future Expansion <br />Adequate <br />❑ Fair <br />Poor <br />❑-Inadequate <br />COMMENTS: L<- 1-loPce-46CZ 60E:7- OF Cu(7 <br />ICAiA)F 671 n i-I/UE< - (ArTW(r 1>91IJ/j PJAJFELL LA_Sj_- MAY P <br />Date of Inspection <br />Septic System <br />This report must be kept on the premises with systern location and pumping records. <br />WHITE COPY / Inspector's File GOLD COPY / Homeowner <br />