Laserfiche WebLink
On the North Sbore of' <br />'.ake ,Minnetonka <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPOR; POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473-7357 <br />OWNER � /�G� /NC, ADDRESS / 3�� C`7C,/J6:_ <br />PERMIT NO.'S. l �o DATES IA -�9/�-�� -�f CONTRACTORS' P`� or�ete <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage <br />treatment system at the above address has been inspected and appears to fall into the category checked below. <br />(This is ❑ an existingrn T <br />system ❑ new construction)�r pt0�i:%Ef' fit iYT>'7u►'--1, <br />R7 1 Meets or exceeds current City standards in all respects relating to design, construction, and location, Appears to be operating <br />properly. Xr <br />2 Does not most all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />El3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br />this time. <br />4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION Checked items may require your action) <br />Tank ' spection indicates: <br />Tank <br />not needed at this time. <br />❑ Solids accumulation in tanks indicates they should be pump. <br />ed out this yew to help prevent future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as won in possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection risen missing —tanks could not be inspected. <br />Inspection risen 14" dia. pipe{ must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years :hey should be pumped out now. <br />❑ Inspection pipe is located directly over tank beffle. (Does not <br />gi accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Dram eld inspection indicates: <br />Drainfield is dry, no surfacing evident. <br />❑ Some evidence of surfacing, not critical yet. <br />❑ Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace- <br />ment or additions to drainfield. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />❑ Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS: <br />Limiting Site Factors <br />Potential for System Failure <br />Site Capabilifies for <br />❑ Slope <br />(depends on soil types, water <br />Future Expansion <br />❑ Soil <br />'KHigh water table <br />table, nd system condition) <br />Low <br />❑ dequate <br />Fair <br />❑ Lot site <br />❑ Medium <br />Poor <br />Lake, wetland, or stream <br />❑ High <br />❑ Inadequate <br />❑ Drainage <br />❑ System is causing visible <br />surface discharge. <br />COMMENTS: <br />;X JJ1AN ?S -TC) C�3gg- <br />/t <br />2- Z 2 - ,F-5V / yG f or�tAN <br />Date of Inspection Septic System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy <br />of the system under current conditions based on the available information. <br />Th report must be kept on the premises with system location and pumping recc,ds. <br />WHITE COPY / Inspector's File GOLD COPY / Homeowner <br />