My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1987-12-03 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
C
>
Crestview Avenue
>
285 Crestview Avenue - 05-117-23-14-0024
>
Septic
>
1987-12-03 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2025 3:14:21 PM
Creation date
5/14/2025 3:12:54 PM
Metadata
Fields
Template:
x Address Old
House Number
285
Street Name
Crestview
Street Type
Avenue
Address
285 Crestview Avenue
PIN
0511723140024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ou the .\twb Shure of <br />Lake Alinnetanka <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />ORONO Crystal Bay, MN 55323 <br />473.7357 <br />Q�55� ( S• An►�1��� _ ADDRESS <br />OWNER _ �—__.�_ — <br />PERMIT NO.'S. Zy�K —DATES CONTRACTORS �t✓r1lPF� <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage <br />treatment system at the above address has been inspected and appears to fall into the category checked below. <br />(This is ❑ an existing system ❑ new construction) <br />Meets or exceeds current City standards in all respects relating to design, construction, and location. Appear, a be operating <br />properly, <br />Z Does not meet all current City standards for new construction (1978 Code) but it most respect: appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is requited at this time. <br />E3 Does not meet current City standards in many respects relatmq to design, construction, or location. Appears to be operating <br />- adequately at this time, but has a relatively high potential for future prohle•ms. No major upgrading of system is required at <br />th-s time. <br />ED 4 System may or may not meet current Crt� standards lot design, construction or location, but is failing to properly treat and <br />dispose of the current input, and is endangering a water supply. or is . jurre of pollution to surface or groundwaters, or is <br />creating a safety harard, or is otherwise - -eating a publ, c nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement nrocedures. 11 dramfield t,s.recement is necessary, soil testing w4l Li%ually be required, and a design and site plan <br />must he submitted for review. You, contractor must obtain a permit before •--.rrted. <br />SYSTEM CONDITION I Ql Checked items may require your action) <br />Tank inspection indicates: <br />APumpout not needed at this time. <br />❑ Solids accumulation in tanks indicates they should be pump- <br />ed out this year to help prevent future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to elimit ate surface discharge. <br />❑ Inspection risers mrssinj -tanks could not be inspected. <br />Inspection risers 14" din. pipe) must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be primped out now. <br />❑ Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Drainfield inspection indicates: <br />8"Drainfield is dry, no surfacing evident. <br />❑ Some evidence of surfacing, not critical yet. <br />❑ Drainfield is satur- and visibly discharging untreated <br />effluent to the su -. This condition may require replace- <br />ment or additions .- drainfield. Contact the City Inspector <br />immediately. Repairs roust be completed within 90 days. <br />❑ Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS <br />Limiting Site Factors <br />Potential foe System Failure <br />Site Capabilities for <br />Slope <br />(depends on soil typos, water <br />Future Expansion <br />Sod <br />table, and system cot dttion) <br />❑ Adequate <br />❑ High water table <br />❑ Low <br />Fair <br />0 Lot sire <br />❑ Medium <br />Poor <br />❑ Lake, wetland, or stream <br />JaHigh <br />❑ Inadequate <br />❑ Drainage <br />❑ System is causing visible <br />surface discharge. <br />COMMENTS -- <br />_-- —---------------- <br />______ . 3 - I" <br />Date of Inspwction <br />IVY ,ke 6. e rs r�_ L1 <br />Septic SysteiVinspector �— <br />Note. In the event that this inspection report is used to satisfy the rertuirements for a mortgage or other transfer of property be advt.ed that <br />this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adeehtdcv <br />of the system under current conditions based on the available mformateon. <br />This report must be kept on the premises with system location and pumping teconls <br />WHITE COPY / Inspector's File GOLD COPY 1 Homeo•.vne. <br />
The URL can be used to link to this page
Your browser does not support the video tag.