1992-02-17 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
C
>
Creekwood Trail
>
4650 Creekwood Trail - 30-118-23-33-0006
>
Septic
>
1992-02-17 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/30/2025 9:47:23 AM
Creation date
4/30/2025 9:37:31 AM
Metadata
Fields
Template:
x Address Old
House Number
4650
Street Name
Creekwood
Street Type
Trail
Address
4650 Creekwood Trail
PIN
3011823330006
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A ` <br />S -P TESTING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br />951 Katydid Lane NE 9 St. Michael, MN 55376 • (612) 497-3566 <br />February 17, 1992 <br />LeGran Homes <br />Lot 4, Block 1 <br />Painters Woods <br />Orono, Henn. Co., MN <br />This On -Site Sewage Treatment System is Designed for a Type 1, ^ix <br />bedroom home in accordance with the Minnesota Pollution Control <br />Agency Chapter 7080 and local ordinances. <br />The soils on this site are SCS soils mapped - L+B - LeSueur loam. <br />A seasonally high water table was legated at 12", 20" & 2211, <br />(mottled soil). Due to the seasonally `sigh water _able, a <br />Pressurized Mound System will need to be installe... The bottom <br />of the rock bed must be located at 1_ast 3' above the seasonally <br />high water table. <br />The soils at a depth of 12" have a percolation rate averaging 12.9 <br />min/inch and are adequate for treatinc naptic effluent. <br />A pumping chamber will need to be installed to lift the effluent to the <br />treatment area. <br />The manifold and supply line pipe must have back drainage to the pumping <br />chamber. The distribution pipes shall have their ends capped. Be sure <br />the rock and sand fill material are clean. The sod layer below the <br />entire mounded area must be turned over, just break up the sod, be sure <br />not to over work. <br />The power supply and switches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device must be <br />installed with a light and sound device, this is in case of a pump failure. <br />(Mercury floats are a good method). <br />All neighboring wells are located greater than 100' away from the <br />proposed treatment area. <br />CONT'D <br />