Laserfiche WebLink
OLD CRYSTAL BAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129SFORONO INDUSTRIAL BOULEVARD <br />ST ST <br />STWFWFWFWFWFWSSSSSSSFWFW EX. BOUNDARY (TYP) <br />EX. STORM SEWER (TYP) <br />8" GATE VALVE <br />N: 171,394.94 <br />E: 445,856.86 <br />8" TEE W/ TB <br />N: 171,395.01 <br />E: 445,842.14 <br />8" TEE W/ TB <br />N: 171,395.69 <br />E: 445,700.14 <br />8" GATE VALVE <br />N: 171,395.87 <br />E: 445,663.988" 90° BEND W/ TB <br />& 6" REDUCER <br />N: 171,396.65 <br />E: 445,499.95 <br />CONNECT TO EX. WATER <br />N: 171,400.01 <br />E: 445,842.17 <br />CONNECT TO EX. WATER <br />N: 171,400.69 <br />E: 445,700.16 <br />5.0 LF~8" C900 WATER MAIN <br />14.7 LF~8" WATER MAIN <br />137.2 LF~8" WATER MAIN <br />125.4 LF~8" WATER MAIN <br />5.0 LF~8" C900 WATER MAIN <br />BUILDING 1 <br />BUILDING 2 <br />BUILDING 3 BUILDING 4 BUILDING 5 <br />8" X 6" TEE W/ TB <br />N: 171,396.05 <br />E: 445,625.39 <br />8" X 6" TEE W/ TB <br />N: 171,396.01 <br />E: 445,633.39 <br />8" X 6" TEE W/ TB <br />N: 171,395.42 <br />E: 445,757.14 <br />8" X 6" TEE W/ TB <br />N: 171,395.38 <br />E: 445,765.14 <br />8" X 6" TEE W/ TB <br />N: 171,394.74 <br />E: 445,899.14 <br />8" X 6" TEE W/ TB <br />N: 171,394.70 <br />E: 445,907.14 <br />8" 90° BEND W/ TB <br />& 6" REDUCER <br />N: 171,394.04 <br />E: 446,044.34 <br />8.0 LF~8" WATER MAIN <br />36.2 LF~8" WATER MAIN <br />8.0 LF~8" WATER MAIN <br />30.6 LF~8" WATER MAIN <br />57.0 LF~8" WATER MAIN <br />8.0 LF~8" WATER MAIN <br />77.0 LF~8" WATER MAIN <br />42.3 LF~8" WATER MAIN <br />METER PIT <br />N: 171,390.24 <br />E: 445,503.95 <br />METER PIT <br />N: 171,389.58 <br />E: 445,620.36 METER PIT <br />N: 171,389.49 <br />E: 445,638.36 <br />METER PIT <br />N: 171,388.94 <br />E: 445,752.11 <br />METER PIT <br />N: 171,388.85 <br />E: 445,770.11 <br />METER PIT <br />N: 171,388.26 <br />E: 445,894.11 <br />METER PIT <br />N: 171,388.18 <br />E: 445,912.11 <br />METER PIT <br />N: 171,387.56 <br />E: 446,040.31 <br />TYPICAL FIRE SERVICE <br />TYPICAL WATER SERVICE <br />SANITARY MAIN (TYP) <br />SANITARY SERVICE (TYP) <br />WET TAP (TYP)WET TAP (TYP) <br />I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM <br />A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. <br />SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM <br />DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: <br />Job No.: <br />FOR AND ON BEHALF OF <br />HAGSTROM ENGINEERING PLLC <br />Checked By:811 <br />CALL 2 BUSINESS DAYS IN ADVANCE BEFORE <br />YOU DIG, GRADE OR EXCAVATE FOR THE <br />MARKING OF UNDERGROUND MEMBER <br />UTILITIES. <br />CALL GOPHER STATE ONE CALL <br />BENCHMARK:ByDateDescription of RevisionsNo.Sheet of <br />D <br />C <br />B <br />A <br />54321 <br />219 6TH AVENUE EAST <br />ALEXANDRIA, MN 56308 <br />P.320.759.0764 <br />WWW.HAGSTROMENG.COM <br />HAGSTROM <br />ENGINEERING <br />CIVIL ENGINEERS | LAND CONSULTANTS <br />CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT <br />C5.0C3.1 <br />C3.1ORONO GARAGE CONDOSSITE PLANPROPOSED UTILITY PLAN03/03/2025 <br />24015 LEHMRH0 <br />SCALE: 1" = <br />ORIGINAL GRAPHIC SCALE <br />15 30 60 <br />30' <br />LEGEND <br />EXISTING STORM SEWER, <br />MANHOLE, F.E.S. AND INLET <br />PROPOSED STORM SEWER, <br />MANHOLE, F.E.S. AND INLET <br />EXISTING ROW <br />PROPOSED ROW <br />EXISTING LOT LINE <br />PROPOSED LOT LINE <br />PROPERTY BOUNDARY <br />PROPERTY SETBACK <br />EXISTING EASEMENT <br />PROPOSED EASEMENT <br />PROPOSED SANITARY SEWER W/ MH <br />EXISTING SANITARY SEWER W/ MH <br />PROPOSED UNDERDRAIN AND CLEANOUT <br />PROPOSED WATER LINE, VALVE AND <br />FIRE HYDRANT <br />EXISTING WATER LINE AND VALVE <br />PROPOSED WATER SERVICE W/ METER <br />PROPOSED SANITARY SERVICE <br />EXISTING GAS LINE <br />EXISTING OVERHEAD ELECTRIC <br />EXISTING ELECTRIC <br />EXISTING CABLE TV <br />EXISTING FIBER OPTIC <br />EXISTING TELEPHONE <br />TYPICAL <br />CAUTION! UTILITY CROSSING <br />LOWERING MAY BE REQUIRED <br />EXISTING LIGHT POLE <br />PROPOSED LIGHT POLEWSS <br />NOTES: <br />1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES <br />PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. <br />2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION <br />STAKING. <br />3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION, SEE SHEET C4.0. <br />4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION <br />SHALL NOT BE DISTURBED. <br />5.ALL UTILITIES WITHIN PROPERTY BOUNDARIES ARE PRIVATE. <br />6.ALL WATER SERVICES ARE 10 LF, XX" DIAMETER UNLESS OTHERWISE NOTED. <br />7.ALL FIRE SERVICES ARE 10 LF, 6" DIAMETER W/ GATE VALVE UNLESS OTHERWISE <br />NOTED. <br />8.ALL WATER MAINS ARE 8" DIAMETER, MAINTAIN POSITIVE GRADE, 8' MIN. COVER. <br />9.ALL WATER MAINS AND SERVICES SHALL MEET AWWA C900 QUALITY STANDARD. <br />10.AN ACCESSIBLE BLUE 14 AWG MINIMUM TRACER WIRE SUITABLE FOR DIRECT BURY <br />MUST BE USED <br />11.SEE SHEET C5.0 - C5.2 FOR CONSTRUCTION DETAILS. <br />TYP <br />EXISTING FIRE HYDRANT <br />LOCATED AT THE MID <br />POINT OF NORTH <br />PROPERTY LINE, TOP NUT <br />OF HYDRANT =1026.02 <br />79