Ott for Nortb Sborr of <br />lake .Ninneronka <br />ON-SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473.7357 <br />OWNER e_;rUf_*— % __ (IC- – ADDRESS - crr�c�, C f-Cln�7�L`7S/11C — <br />PERMITNO.'S. -- DATES --� ---- CONTRACTORS X/7-T�7�' <br />City Orch•iance No. 210 requ-res that each on-site sewage treatment system in Orono he inspected on a regular basis. The onsite sewage <br />treatment system at the above address has Been inspected and appears to fall into the category checked below. <br />ITh s rs an existing systen. ❑ new cons ruction) <br />1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating <br />properly. <br />2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required a• `tis time.. <br />E3 Does not meet current City standards in many respects relating to design, eonsuuetion, or location. Appears to he operating <br />adequately at this time, but has a relatively high potential for future problems. No malrsr upgvAutg of system rf requnect at <br />this time. <br />4 System may of may not meet current City standards far design, construction or It._ -tion he . is fading to r -perly treat and <br />dispose of the current input, and is endangering a water supply, ur is a source of pollution to surface or groundwaters. or is <br />creating a safety harard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary. sad testing will usually be required, and a design and ate plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION 1 [0 Checked items may require your actionl <br />Tank 1 pection indicates <br />umpout not needed at this time. <br />❑ Sol ds accumulation in tanks indicates they should be pump- <br />ed out this year to help prevent future problems. <br />❑ Solios accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumtred <br />within 48 hours to eliminate surface discharge. <br />(71 Inspecti•-in risers missing—tanks could not be inspected:. <br />Inspection risers (4" ilia. pipe) must be installed in each tan/ <br />at next ptimpout. If tanks have not been pumped out within <br />the last thr-e years, they should be pumped out now. <br />SITE CHAR ACTEI'ISTICS <br />r imrting Site Factors <br />❑ Slope <br />❑ Soil <br />�Hinti water table <br />Lrtsi •e <br />❑ Lake, s •etland, or sreame <br />❑ Drainage <br />COMMENTS __ <br />L] Inspect on pipe is located directly over tank baffle. Woes not <br />give accurate measurement of solids accumulation.) If tanees <br />have not been pumped out within the last three years, they <br />should be pumped out now <br />Diamfie d inspection indicates <br />tamfield is dry, no surfacing evident, <br />Ci Some evidence of surfacing, not critical yet. <br />�] Drainfreld is saturated anti visibly discharging untreated <br />effluent to the surface. This condition may, requite replace• <br />ment or additions to drainfield Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />(_ 1 Drainfreld extent and condition unknown. <br />Potential for System Failure <br />(depends on soil types, water <br />table, d system condition) <br />ow <br />L Medium <br />❑ High <br />❑ System is causing visible <br />surface discharge. <br />Date cf Inspection Septic System In <br />Site Capabilities for <br />F utur E xpansion <br />Adequate <br />(� Fair <br />:) Poor <br />7Inadequate <br />Note In the event that this inspection repoit is used to satisfy the requirements for a mortgage or other transfer of property be aoufwd that <br />this report does not guarantee or certify that an existing system will continue to function properly bus is merely an opinion of the aAequacy <br />of the system under current conditions based on the available information. <br />This report must be kept on the premises with sVstern Iodation and oumping records <br />WHITE COPY I Inspectui's I de GOLD COPY : Homeowner <br />