My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1985-11-06 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
C
>
Countryside Drive
>
2475 Countryside Drive - 04-117-23-11-0006
>
Septic
>
1985-11-06 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2025 12:19:21 PM
Creation date
4/2/2025 12:13:36 PM
Metadata
Fields
Template:
x Address Old
House Number
2475
Street Name
Countryside
Street Type
Drive
Address
2475 Countryside Drive
PIN
0411723110006
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
()ft t1w .Vorlb Sborn, of <br />Lakd- Allunclonkd <br />ON-SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX 66 <br />. 1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473-7357 <br />OWNFR LSE T t- ADDRESS ---2"._Z._-����/Ui7f�yS/L <br />PERMIT NO.'S. ASP ==- DATES -.1�L� _s� =J CONTRACTORS-"�'S���Z!ar�. . <br />City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sawssip <br />treatment system at the above address has been inspected and appears to fall into the category chocked below. <br />ITh,, is 1*1 an existing system new construction) <br />Meets or exceeds curie, City standards in all respects relating to design, construction, and location. Appears to be operating <br />properly. <br />2 Does not meet all current City standards for new construction ( 1978 Code) but in most respects appears to be itlesigrtad, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no rw4w <br />upgrading of the system is required at this time. <br />D3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating <br />adequately at this time, but has a rela•ively high tmtentia; for future piohlpms. No major upgrsdrng of system is required at <br />this lime. <br />4 System may or may riot meet current City standdids for design, construction or location, but is failing to properly Item and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to e1NfaCo or grplftdl" . W is <br />creating a safety haiaid, or is otherwise creating a public nuisanc+. Please contact the City IMpaetor to discuss systlMn repent <br />replacement procedures. If drainfield replacement ,s necessary, soil testing will usually be required, atdsidesign and site plain <br />must be submitted lot review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION I [Z Checked items may require your action) <br />Tank s rection indicates <br />Pumpout not needed at this time. <br />❑ Solids accumulation in tanks indicates they should be pump- <br />ed out this year to help prevent future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection -isers missing -tanks could not be inspected. <br />Inspection risers (4" ora. pipe) must be installed in each tank <br />at next pumpout. If tanks have not leen pumped out within <br />the last three years, they shouid be pumped out now. <br />U Inspection pipe is I jcated directly over tank baffle. (Does not <br />give accurate mei.surement of solids occw- stints.) If tanks <br />have not been pumped out within the las tree years, th@V <br />should be pumped out now. <br />Dtainj*pld inspection indicates <br />Orainfield is dry, no surfacing evident. <br />❑ Some evidence of surfacing, not critical yet. <br />❑ Dramfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replad- <br />ment or additions to drainfineld. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days, <br />❑ Dramfield er.rent and condition unknown, <br />SITE CHARACTERISTICS <br />Limiting Site Factors <br />Potential for System Failure <br />Site Capabilities for <br />❑ Slope <br />(depends on soil types, water <br />Fut E xpansmon <br />U�CoI <br />table, and system contrition) <br />Adequate <br />AM-rhgh water table <br />PKILOW <br />❑ Fair <br />❑ Lot site <br />U Medium <br />❑ Poor <br />❑ Lake, wetland, or stream <br />1-J High <br />❑ Inadequate <br />❑ Drainage <br />U System is causing visible <br />surface discharge. <br />COMMENTS — -- <br />--- ---- <br />-------- <br />-- ---- <br />Date of Inspection Septic System In — <br />Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does riot quarantPe or certify that n existing system will continue to function proppily, but is merely an opinion of the adequacy <br />of the system under current conditions based o - available information <br />This report must be kept on t1•,r premises with system location and pumping records. <br />WHITE COPY ! Inspector's 1- de GOLD COPY ! Homeowner <br />