My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1982-09-13 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
C
>
Countryside Drive
>
2475 Countryside Drive - 04-117-23-11-0006
>
Septic
>
1982-09-13 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2025 12:19:21 PM
Creation date
4/2/2025 12:09:41 PM
Metadata
Fields
Template:
x Address Old
House Number
2475
Street Name
Countryside
Street Type
Drive
Address
2475 Countryside Drive
PIN
0411723110006
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO <br />GENERAL CONSTRUCTION REQUIREMENTS <br />MOUND DRAINFIELD SYSTEM <br />TO BE USED WHERE: Seasonal perched water table is between 2 feet and 4 feet <br />below surface. Percolation rate in top 12" of soil is <br />faster than 60 MPI. Percolation rate in subsoil but above <br />water table is faster than 120 MPI. Where percolation rate <br />is 60-120 MPI, depth to groundwater shall be at least 31 <br />and slope must be no more than 34. Where percolation rate <br />is 30-60 MPI, depth to groundwater shall be at least 2# <br />and slope must not exceed 64. If percolation rate is faster <br />than 30 MPI, depth toggroundwater shall be at least 31 and <br />slope must not exceed 6-124. <br />CONNECTION TO <br />HOUSE House to tanks may be PVC (ASTM D-3034 or better), <br />cast iron or clay tile. PVC should be sand -bedded <br />in flat runs over long distances. No outside air test <br />required but joints must be tight. <br />TANKS Two (2) precast concrete tanks are required. Min. size <br />1000 gal. and'750 gal.; we recommend 2 1000's..Tanks <br />must have 20" manhole riser to within 12" of final <br />Erade, and at least one 4"-6" inspection stack to <br />surface. Baffles must be acid resistant and may be <br />plastic, fiberglass, or precast with tank. <br />DRAINFIELD Mound consisting of 12-24" layer of sand on plowed, chopped, <br />or otherwise scarified natural surface soil. 12" rock bad <br />on top of sand layer, 10' maximum width X length dependent <br />on water use. Distribution pipe is laid in top 3" of rock. <br />Cover rock bed with straw or hay AND building paper. A <br />layer of sandy loam 6-12" thick should be placed over the <br />covered rock bed and a 6" layer of topsoil then placed over <br />the entire mound. Finished sidealopes to be 3:1 or flatter. <br />Grass cover should be established as soon as possible over <br />the mound area to reduce erosion and aid in evaporation. <br />THE MOST IMPORTANT STEP IN CONSTRUCTING A MOUND IS <br />PREPARING THE NATURAL SOIL SURFACE BY DISC -PLOWING <br />OR CHOPPING WITH A BACKHOE TO A DEPTH OF ABOUT 12". <br />When sand is pushed or dropped onto this loosened raw top- <br />soil (DON'T drive on it), an interface is formed which will <br />allow percolation to occur from the sand into the topsoil. <br />SEE SKETCH ON BACK OF THIS SHEET. <br />DISTRIBUTION The mound must use pressure distribution and requires a <br />pump from the sotic tanks. Distribution must be 1V PVC <br />or plastic with K" holes (turned down) every 36". Pumping <br />from a 2" manifold, distribution system should be 3 lengths <br />of pipe spaced 40" on center capped at the ends, running <br />the length of the rock bed (see sketch). No drop boxes or <br />distribution boxna are used. 4" PIPE WITH GRAVITY DISTRIB- <br />UTION IS NOT ACCEPTABLE IN A MOUND SYSTEM. <br />
The URL can be used to link to this page
Your browser does not support the video tag.