My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1983-08-05 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
C
>
Countryside Drive
>
2450 Countryside Drive - 04-117-23-11-0004
>
Septic
>
1983-08-05 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2025 10:31:19 AM
Creation date
4/2/2025 10:25:40 AM
Metadata
Fields
Template:
x Address Old
House Number
2450
Street Name
Countryside
Street Type
Drive
Address
2450 Countryside Drive
PIN
0411723110004
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHITT <br />TO: Jeanne A. aMabusth, Zoninq Administrator <br />FROM: Michael 1'. Gaffron, Septic System Inspector <br />DATE: November 6, 1981 <br />SUBJECT: #654 Dicon, Willow Drive South - Subdivision <br />I have reviewed the submitted report for the above referenced <br />proposed subdivision, and wish to make the following comments: <br />The report by Borg in -'i --!--s high -water -table soils throughout <br />the 6 lots tested. <br />Lot 1 - Slopes of 8%, 10�. Percolation rates at a depth of <br />25" - 31" averaged 10 mpi in the primary site and 23 mpi <br />for the alternate site. Both sites are acceptable for <br />standard mound systems. <br />Lot 2 - Slopes of 4-68 in areas tested. elation rates <br />averaged 25 mpi in the primary site and 1 -i in the alternate <br />site. Both sites are acceptable for stanaird mound systems. <br />Lot 3 - Slopes of 5% - 6% in areas tested. Average percolation <br />rates averaged 27 -mpi for the primary site, and 34 mpi in the <br />alternate site. Both sites are acceptable for standard mound systems. <br />Lot 4 - Slopes of 3-4% in areas tested. Percolation rates <br />averaged 41 mpi in primary site and 20 mpi in the alternate <br />site. Both sites are acceptable for stanuard mound-systema- <br />Lot <br />oundsvG*ema_Lot 11 - Slopes of 8-10% in areas tested percolation rates <br />and 31m i at the alternate <br />site. NOTE: CARE MUST BE TAKEN TO PLAC—E--T-TIED ON <br />SLOPE OF 6% OR LESS ON THIS LOT.Lo_..- I I <br />Lot 10 - Slopes average 6%. Percolation rates averaged 48 mpi <br />on the primary site and 87 mpi on the alternate site. B(.ptK <br />General Comments: Percolation testing was done at a range of <br />depths from 13" to 31". No real correlation appears to exist <br />between depth of testing and percolation rates. The soil <br />borings refle:t a seasonably saturated zone beginning at a <br />a range of depths from 1.2 ft to 2.5 ft. Actual current <br />perched water tables were found on some sites at a depth <br />of 3.5 ft. or greater. <br />Based on the above da`a, the site evaluations recommendation <br />for all mound systems is appropriate. I confirmed the soil <br />boring report with a boring of my own. <br />
The URL can be used to link to this page
Your browser does not support the video tag.