My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1995-07-25 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
C
>
Copper View Drive
>
2685 Copper View Drive - 33-118-23-43-0018
>
Septic
>
1995-07-25 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2025 3:51:12 PM
Creation date
3/26/2025 3:07:10 PM
Metadata
Fields
Template:
x Address Old
House Number
2685
Street Name
Copper View
Street Type
Road
Address
2685 Copper View Road
PIN
3311823430018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S -P TESTING, INC. Steven F-. Schirmers — ';APCA Cert No. 627 <br />951 Katydid Lane NE • St. Michael, MN 55376 • (612) 49'r 3&66 <br />July 25, 1995 <br />Mike Hilbelink <br />Lot 2, Block 1 <br />Rosch Addition <br />Orono, Henn. Co., MN <br />This On -Site Sewage Treatment System is Designed for a Type 1, five <br />bedroom home Designed in accordance with the Minnesota Pollution <br />Control Agency Chapter 7080 and local ordinances. <br />The soils on this site are a clay loam. A Seasonally high water <br />table was located at. 14" to 22", (mottled scil). Due to the <br />seasonally high water table, a Pressurized Mound System will need <br />to be installed. The bottom of the rock bei must be located at <br />least 3' above the seasonally high water ta:)le. <br />The soils at a depth of 12" have a percolat.Lon rate avera,3ing <br />9.8 min/inch. <br />A pumping chamber will need to be installed to lift the effluent <br />the treatment area. <br />The manifold and supply line pipe must have back drainage to the <br />pumping chamber. The distribution pipes shall have their ends <br />capped. Be sure the rock and sand fill material are clean. The <br />sod layer below the entire mounded area must be turned over, just <br />break up the sod, be sure not to over work. <br />The power supply and switches must be located outside the manhole <br />and pumping chamber in a weather proof enclosure. A warning device <br />must be installed with a light and sound device, this is in case of <br />a pump failure. <br />All neighboring wells are located greater than 100' away from the <br />proposed treatment area. <br />CONT'D <br />
The URL can be used to link to this page
Your browser does not support the video tag.