REMOVABLE <br />BOTTOM OF INLET <br />PIPE SHOULD HE A <br />MIN I" HIGHER THAN <br />BOTTOM OF OUTLET <br />PIPE, <br />1 NLET <br />DISTRIBUTION BOX <br />COVER- <br />- <br />s <br />jou <br />L- BAFFLE <br />EACH TILE FIELD LATERAL SHALL BE <br />CONNECTED SEPARATELY AND NOT <br />SUBDIVIDED. INVERTS SHALL BE AT <br />THE SAME ELEVATION. OUTLET PIPES <br />SHOULD HAVE EOUAL SLOPES FOR 5 <br />FEET AFTER LEAVING BOX. <br />0 <br />0., <br />_OUTLET <br />900 OR 450 ELBOWS TO OBTAIN <br />DESIRED LATERAL TILE LINE <br />SEPARATION. <br />BAFFLE TO BE USED WHEN EFFLUENT IS DELIVERED BY <br />PUMP OR SIPHON, OR THE SLOPE OF THE INLET LINE <br />IS SUCH THAT UNEVEN DISTRIBUTION COULD OCCUR. TOP <br />OF THE BAFFLE AT LEAST LEVEL WITH THE CROWN OF <br />THE INLET PIPE. <br />DETAIL 16 <br />