1986-10-02 Plan Review
Orono
>
Property Files
>
Street Address
>
C
>
Colin Drive
>
2150 Colin Drive - 03-117-23-21-0015
>
Permits/Inspections
>
1986-10-02 Plan Review
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 10:33:12 AM
Creation date
2/20/2025 10:14:13 AM
Metadata
Fields
Template:
x Address Old
House Number
2150
Street Name
Colin
Street Type
Drive
Address
2150 Colin Drive
PIN
0311723210015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN REVIEW - 95 SOUTH BROWN ROAD <br />October 2, 1986 <br />Page 3 <br />FRAMING AND CARPENTRY <br />22. All foundation sills or plates which are within 8" of finished <br />grade or rest on masonry or concrete slab shall be pressure treated <br />wood. Foundation grade redwood or cedar may be substituted. Sec. <br />2516-c-3-7. (Note with the latter galv. nails should be used). <br />23. Wood joists or the bottom of wood f loors closer than 18" or wood <br />girders closer than 12" to the ground underfloor arQas shall be <br />pressure treated lumber, or as listed in 2517-c-3. Sec. 1516-c-2. <br />24. Accessible underf loor areas sha 11 be provided with an 18" x 24" <br />access crawl hole. Sec. 2516-c:-2. <br />25. Underfloor areas shall be provided with ventilation to meet intent <br />of Sec. 2516-c-6. Net area of not less than 1-1/2 sq. ft. per 25 lin. <br />ft. of ext. wall. <br />26. No wood other than permitted by Sec. 2516-c-3 shall be closer than <br />6" to any earth unless separated by concrete at least 3" thick with an <br />impervious membrane installed between the earth and concrete. Sec. <br />2516-c-7. <br />27. The ends of beams or girders supported on masonry or concrete <br />shall have not less than 3" of bearing. Sec. 2517-c. <br />28. Foundation plates or sills shall be bolted as required by Sec. <br />2907-e. <br />Z9. Girders shall be designed to carry all loads imposed on them, end <br />joints shall occur over supports. when spliced over support, an <br />adequate tie shall be provided. Sec. 2517-c. <br />30. Each joists shall have not less than 1-1/2" bearing on wood or <br />metal, nor less than 3" on masonry. Sec. 2517-d-2. <br />31. Joists shall be supported laterally at the ends and at each <br />support by solid blocking not less than 2" in thickness and full depth <br />of joists. Sec. 2517-d-3. <br />32. Joists framed from opposite sides if a beam, girder or partition <br />shall be lapped at least 4 inches, or the opposing joists shall be <br />tied together in an approved manner. Sec. 2517-d-3. <br />33. Joists framed into the side of a wood girder shall be supported by <br />framing anchors or on a ledger strip not less than 2"x2". Sec. 2517- <br />d-3. <br />34. Framing around openings; trimmer and header joists shall be <br />doubled when span exceeds four (4) feet. Sec. 2517-d-4. <br />