Laserfiche WebLink
OLD CRYSTAL BAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129SFORONO INDUSTRIAL BOULEVARD <br />ST ST <br />ST <br />S S S S S S <br />WFWFWFWFWFWFWFWSSSSSSSEX. BOUNDARY (TYP) <br />EX. WATER (TYP) <br />EX. STORM SEWER (TYP) <br />8" GATE VALVE <br />N: 171,394.94 <br />E: 445,856.86 <br />8" TEE W/ TB <br />N: 171,395.01 <br />E: 445,842.14 <br />8" TEE W/ TB <br />N: 171,395.69 <br />E: 445,700.14 <br />8" GATE VALVE <br />N: 171,395.87 <br />E: 445,663.988" 90° BEND W/ TB <br />& 6" REDUCER <br />N: 171,396.61 <br />E: 445,509.15 <br />CONNECT TO EX. WATER <br />N: 171,400.01 <br />E: 445,842.17 <br />CONNECT TO EX. WATER <br />N: 171,400.69 <br />E: 445,700.16 <br />5.0 LF~8" C900 PRIVATE WATER MAIN <br />14.7 LF~8" C900 PRIVATE WATER MAIN <br />122.0 LF~8" C900 PRIVATE WATER MAIN <br />100.0 LF~8" C900 PRIVATE WATER MAIN <br />5.0 LF~8" C900 PRIVATE WATER MAIN <br />EX. SSMH-1 <br />4' SSMH <br />N: 171,410.28 <br />E: 445,777.76 <br />BUILDING 1 <br />BUILDING 2 <br />BUILDING 3 BUILDING 4 BUILDING 5 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />23 <br />24 <br />25 <br />26 <br />27 <br />28 <br />29 <br />30 <br />31 <br />32 <br />33 <br />34 <br />35 <br />36 <br />37 <br />38 <br />39 <br />40 <br />41 <br />42 <br />43 <br />44 <br />45 46 <br />47 <br />48 <br />49 <br />50 <br />51 <br />52 <br />53 <br />54 <br />55 <br />56 <br />57 <br />58 <br />59 <br />60 <br />61 <br />62 <br />63 <br />64 <br />65 66 <br />67 <br />68 <br />69 <br />70 <br />71 <br />72 <br />73 <br />74 <br />75 <br />76 <br />77 <br />78 <br />79 <br />80 <br />81 <br />82 <br />83 <br />84 <br />85 <br />8" X 6" TEE W/ TB <br />N: 171,396.13 <br />E: 445,609.14 <br />8" X 6" TEE W/ TB <br />N: 171,396.03 <br />E: 445,629.14 <br />8" X 6" TEE W/ TB <br />N: 171,395.45 <br />E: 445,751.14 8" X 6" TEE W/ TB <br />N: 171,395.35 <br />E: 445,771.14 8" X 6" TEE W/ TB <br />N: 171,394.77 <br />E: 445,893.14 <br />8" X 6" TEE W/ TB <br />N: 171,394.67 <br />E: 445,913.14 <br />8" 90° BEND W/ TB <br />& 6" REDUCER <br />N: 171,394.08 <br />E: 446,035.14 <br />20.0 LF~8" C900 PRIVATE WATER MAIN <br />36.2 LF~8" C900 PRIVATE WATER MAIN <br />20.0 LF~8" C900 PRIVATE WATER MAIN <br />34.8 LF~8" C900 PRIVATE WATER MAIN <br />51.0 LF~8" C900 PRIVATE WATER MAIN <br />20.0 LF~8" C900 PRIVATE WATER MAIN <br />71.0 LF~8" C900 PRIVATE WATER MAIN <br />36.3 LF~8" C900 PRIVATE WATER MAIN <br />METER PIT <br />N: 171,390.19 <br />E: 445,514.15 <br />METER PIT <br />N: 171,388.10 <br />E: 445,604.13 METER PIT <br />N: 171,389.61 <br />E: 445,634.10 <br />METER PIT <br />N: 171,389.08 <br />E: 445,746.14 <br />METER PIT <br />N: 171,388.93 <br />E: 445,776.14 <br />METER PIT <br />N: 171,388.40 <br />E: 445,888.14 <br />METER PIT <br />N: 171,388.25 <br />E: 445,918.14 <br />METER PIT <br />N: 171,387.71 <br />E: 446,030.14 <br />TYPICAL 6" FIRE SERVICE <br />TYPICAL WATER SERVICE <br />14.0 LF WATER <br />SERVICE <br />14.0 LF 6" FIRE <br />SERVICE W/ <br />GATE VALVE <br />8" PRIVATE SANITARY MAIN <br />6" SANITARY SERVICE (TYP) <br />8" PRIVATE <br />SANITARY MAIN <br />6" SANITARY SERVICE (TYP) <br />I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM <br />A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. <br />SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM <br />DATE: 09/18/2024 LICENSE NUMBER: 50731 Designed By:Date: <br />Job No.: <br />FOR AND ON BEHALF OF <br />HAGSTROM ENGINEERING PLLC <br />Checked By:811 <br />CALL 2 BUSINESS DAYS IN ADVANCE BEFORE <br />YOU DIG, GRADE OR EXCAVATE FOR THE <br />MARKING OF UNDERGROUND MEMBER <br />UTILITIES. <br />CALL GOPHER STATE ONE CALL <br />BENCHMARK:ByDateDescription of RevisionsNo.Sheet of <br />D <br />C <br />B <br />A <br />54321 <br />219 6TH AVENUE EAST <br />ALEXANDRIA, MN 56308 <br />P.320.759.0764 <br />WWW.HAGSTROMENG.COM <br />HAGSTROM <br />ENGINEERING <br />CIVIL ENGINEERS | LAND CONSULTANTS <br />CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRIN <br />C5.0C3.1 <br />NOT FOR CONSTRUCTIONC3.1ORONO GARAGE CONDOSSITE PLANPROPOSED UTILITY PLAN09/18/2024 <br />24015 LEHMRH0 <br />SCALE: 1" = <br />ORIGINAL GRAPHIC SCALE <br />15 30 60 <br />30' <br />LEGEND <br />EXISTING STORM SEWER, <br />MANHOLE, F.E.S. AND INLET <br />PROPOSED STORM SEWER, <br />MANHOLE, F.E.S. AND INLET <br />EXISTING ROW <br />PROPOSED ROW <br />EXISTING LOT LINE <br />PROPOSED LOT LINE <br />PROPERTY BOUNDARY <br />PROPERTY SETBACK <br />EXISTING EASEMENT <br />PROPOSED EASEMENT <br />PROPOSED SANITARY SEWER W/ MH <br />EXISTING SANITARY SEWER W/ MH <br />PROPOSED UNDERDRAIN AND CLEANOUT <br />PROPOSED WATER LINE, VALVE AND <br />FIRE HYDRANT <br />EXISTING WATER LINE AND VALVE <br />PROPOSED WATER SERVICE W/ METER <br />PROPOSED SANITARY SERVICE <br />EXISTING GAS LINE <br />EXISTING OVERHEAD ELECTRIC <br />EXISTING ELECTRIC <br />EXISTING CABLE TV <br />EXISTING FIBER OPTIC <br />EXISTING TELEPHONE <br />EXISTING IRRIGATION <br />CAUTION! UTILITY CROSSING <br />LOWERING MAY BE REQUIRED <br />EXISTING LIGHT POLE <br />PROPOSED LIGHT POLEWSS <br />NOTES: <br />1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES <br />PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. <br />2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION <br />STAKING. <br />3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION, SEE SHEET C5.0. <br />4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION <br />SHALL NOT BE DISTURBED. <br />5.ALL SANITARY SEWER SERVICES ARE 6" DIAMETER WITH 1% SLOPE AND A <br />STANDARD 1.2' WYE CONNECTION TO THE 8" PRIVATE MAIN UNLESS OTHERWISE <br />NOTED. <br />6.ALL PRIVATE WATER MAINS ARE 8" DIAMETER, MAINTAIN POSITIVE GRADE, 8' MIN. <br />COVER. <br />7.ALL WATER MAINS AND SERVICES SHALL MEET AWWA C900 QUALITY STANDARD. <br />8.AN ACCESSIBLE BLUE 14 AWG MINIMUM TRACER WIRE SUITABLE FOR DIRECT BURY <br />MUST BE USED <br />9.SEE SHEET C5.0 - C5.2 FOR CONSTRUCTION DETAILS.P:\24015_Orono Car Condo's\CAD\CD's\24015_C3.1-Proposed Utility Plan.dwg, 1/21/2025 4:13:17 PM, 1:1, LEH82