Laserfiche WebLink
NOTES <br />1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY! <br />2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT. <br />3. 24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDED FORALL UTILITY EQUIPMENT. <br />4. THE PRODUCTION METER & AC DISCONNECT SHOULD BE LOCATED TOGETHER VISIBLE -OPEN LOCKABLE READILY ACCESSIBLE LOCATION <br />WITHIN 10' OF THE MAIN SERVICE METER. <br />5. THE METER SOCKET FOR THE PV PRODUCTION METER SHALL BE MARKED WITH A STAMPED BRASS, ALUMINUM, OR STAINLESS STEEL TAG, <br />INDICATING THE ADDRESS INCLUDING THE UNIT, TYPICALLY "PV PROD" IN ACCORDANCE WITH THE REQUIREMENTS FOR "METER <br />IDENTIFICATION" IN SECTION 4.14.4 OF THE XCEL ENERGY STANDARD, OR AS MAY BE AMENDED. <br />6. THE PV PRODUCTION METER SHALL BE LOCATED WITHIN TEN (10) FEET OF THE EXISTING UTILITY METER. IF THERE IS ANY REASON THIS <br />CANNOT BE ACCOMPLISHED, THE APPROVAL OF THE PROPOSED PV PRODUCTION METERING WILL NEED TO BE OBTAINED BY THE LOCAL <br />ELECTRIC METER SHOP. <br />1 %% 1 11 A r% r% 1 11 r M A TT R Er" /'-'% <br />IQ7HS <br />Photovoltaic System <br />DC SYSTEM SIZE 7.470 kW <br />AC SYSTEM SIZE 6.912 kW <br />TOTAL MODULE COUNT 18 <br />NOTE: AC DISCONNECT TO BE INSTALLED <br />WITHIN 10FT FROM UTILITY METER. <br />AHJ: HENNEPIN COUNTY <br />UTILITY: WRIGHT HENNEPIN <br />CONDUCTOR SCHEDULE <br />SPECIFIED CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE SPECIFIED <br />TAG # <br />DESCRIPTION <br />1 <br />INVERTER OUTPUT (TRUNK CABLE) <br />EGC(BARE COPPER GROUND <br />2 <br />INVERTER OUTPUT (THWN-2) <br />EGC(THWN-2) <br />3 <br />INVERTER OUTPUT(THWN) <br />EGC(THWN) <br />4 <br />INVERTER OUTPUT(THWN) <br />5 1 INVERTER OUTPUT(THWN) <br />WIRE GAUGE <br /># OF CONDUCTORS/COLOR <br />12 AWG <br />6(31-1, 31-2) <br />6 AWG <br />1 BARE <br />12 AWG <br />6(3L1, 3L2) <br />12 AWG <br />1(GRN) <br />6 AWG <br />3(L1,L2,N) B/R/W <br />10 AWG <br />1(GRN) <br />6 AWG <br />3(L1,L2,N) B/R/W <br />4/0 AWG AL I 3(L1,L2,N) B/R/W <br />CONDUIT TYPE I CONDUIT SIZE <br />FREE AIR <br />FMC <br />SCH 80 PVC <br />SCH 80 PVC <br />041F."Iffl li <br />N/A <br />3/4" <br />WOL"F�RIVER <br />ELECTRIC <br />1`f WOLF RIVER ELECTRIC <br />101 ISANTI PARKWAY NE, <br />1�� SUITE G ISANTI, MN 55040 <br />2" ELECTRICAL LICENSE: <br />EA777669 <br />Building License <br />BC773271 <br />Contact: (763) 229-6662 <br />contact@wolf rive relectric.com <br />;ISITING UTILITY METER <br />-PHASE, 3W 120V/240V <br />NEW UTILITY EXPORT <br />METER MILBANK U4801 <br />-XL-TG-KK 1-PHASE <br />3-WIRE 120/240V <br />EXISTING 240V/200A <br />BUSBAR RATING, SERVICE <br />PANEL SINGLE PHASE <br />WITH 100A DISCONNECT <br />DESIGNED BY: <br />WOLF RIVER <br />ELECTRIC <br />-AW96-7 6ni- <br />Designer Signature <br />Q*�iy , �p1�11FACTl/� f * �D�fi <br />H <br />L <br />IW <br />� <br />C <br />tl COMPLETE <br />_ <br />KY <br />w <br />z <br />z <br />Q <br />N <br />z CD <br />a <br />o <br />[V <br />� <br />z <br />oC <br />z <br />�o <br />LMn <br />U <br />_ <br />Ln <br />Z <br />m <br />> <br />CL <br />w <br />(D <br />w <br />Im <br />z <br />oC <br />w <br />Ln <br />� <br />_ <br />° <br />�0 <br />:D <br />:D <br />Revisions Table <br />Description I Date I Rev. ■ <br />Sheet Name & <br />Creation Date <br />3-LINE <br />SHEET <br />VISIBLE OPEN LOCKABLE <br />#6 AWG COPPER 01/24/2025 <br />Sheet Number <br />READILY ACCESSIBLE GROUND <br />REFERENCE POINT NEW GROUNDING D-2.1 <br />OF APPLICABILITY ELECTRODE SYSTEM <br />