Laserfiche WebLink
� <br /> SEPTIC SYSTEM INVENTORY / <br /> Addr: 1220 Brackett' s Pt . Rd. PID: 11-117-23 32 0014 <br /> Building Type : residence # BRs/GPD: 4 # Systems/units : 2/1 <br /> Permit No: 996 Date of Permit : 11/18/65 Installer: Sullivan <br /> System Type : standard trench Appliances : lndry <br /> SYSTEM CONDITION <br /> Conformity: 3 Tank Condition: 5-9 DF condition: 11 <br /> Failure Pot : medium <br /> SEPTIC TANKS <br /> Material : concrete block Capacity: 800, 800, 150 , 150 <br /> Setback to Bldg: 20 <br /> DRAINFIELD <br /> Length of Lines : 290 No. Lines : 6 Trench Width: 2 <br /> Treatment Area : 580 Type of Filter: rock <br /> Tile Size : 5 Under Tile : Perc Rate mn/in: <br /> Setback DF-Bldg: 30 DF Ht above WT: 0 <br /> Soil Type : loamy sand Limitations : water table <br /> WELL DATA <br /> Setbacks - Well-Tanks : Well-DF: <br /> Report in File? : Pump Type : <br /> Depth: Diameter: Method: <br /> INSPECTION RECORD PUMPOUT RECORD <br /> Date Compliance Date Gallons <br /> 6/25/81 no surfacing 2 11/1/78 1500 <br /> 12/28/84 tanks inspected; also DF for softener 2 8/14/90 2000 <br /> 7/23/87 no surfacing 2 5/4/92 1500 <br /> 7/23/90 no surfacing-need risers 2 3/1/96 2000 <br /> 9/17/92 no surfacing-need risers 2 3/8/96 2000 <br /> 5/2/94 non-conforming-repair by 12/31/96 3 3/15/96 2500 <br /> 3/21/96 1000 <br /> 3/27/96 1500 <br />