1988-06-30 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road South
>
860 Brown Road South - PID: 10-117-23-12-0001
>
Septic
>
1988-06-30 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2024 10:00:25 AM
Creation date
9/19/2024 9:58:32 AM
Metadata
Fields
Template:
x Address Old
House Number
860
Street Name
Brown
Street Type
Road
Street Direction
South
Address
860 Brown Road South
PIN
1011723120001
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />ON SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />( • : V <br />ORi )N< <br />OWNER a AODRESS i <br />On the Sortb Shore of <br />l.ak*' yinnetonko <br />POST OFFICE BOX 66 <br />1336 S. Brown Rd. <br />Ctystal Bay, MN 55323 <br />473-7357 <br />f Rt > LiVi Qocici <br />PERMIT NO.'S.DATES CONTRACTORS <br />spected on a regular basis. The on>site sewage <br />ked below. <br />? <br />□ 2 <br />□ 3 <br />□ 4 <br />City Ordinance No. 210 requires that each on*site sewage treatrhtnt system in Oro«' <br />treatment system at the above address has been inspected and appeacis to fail ».ito the catC‘* <br />(This is^t3^n existing system □ new construction) <br />n \ Meets or exceeds current City standards m all respects relating to design, construction, and location. Appears to be ofieratin^ <br />properly. <br />Does not meet all current C:»ty standards for new construction 11978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no maior <br />upgrading of the system is required at this time. <br />Does not meet current City standards in many respects relating to design, construction, or location. Appears to be oi>erating <br />adequately at this time, but has a relatively high potential for future problems. No rnaior upgrading of system is required at <br />this time. <br />System may or may not meet current City standards lor design, construction or location, but is failing to properly treat and <br />dispose of the current input, and is endangerirsg a water supply, or it a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan <br />must be submitted for review. Your contractor must obtain a i>ermit before work is started. <br />SYSTEM CONDITION ( Q) Checked items may require your action) <br />Tank inspection indicates: <br />□ Pumpout not needed at this time. <br />□ Solids accumulation in tanks indicates they should be pump* <br />ed out this year to help prevent future problems. <br />G Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />O System is discharging to surface. Tanks must be pumped <br />^within 48 hours to eliminate surface discharge. <br />Ni£^ Inspection risers missing—tanks could not be inspected. <br />/^Inspection risers 14" die. pipe) must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />SITE CHARACTERISTICS: <br />Limiting Site Factors <br />□ Slope <br />□ Soil <br />□ High water table <br />□ Lot sire <br />□ Lake, svetland. or stream <br />□ Drainage <br />□ Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Drainfield inspection indicates <br />D Drainfield is dry. no surfacing evident. <br />G Some evidence of surfacing, not critical yet. <br />G Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace <br />ment or additions to drainfield. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />Drainfield extent and condition unknovm^ Z' <br />Potential for System Failure <br />(depends on soil types, water <br />table, and system condition) <br />G Low <br />G Medium <br />G High <br />G System is causing visible <br />surface discharge. <br />Site Capabilities for <br />Future^ xpansion <br />"^TS^kdequate <br />^Fair <br />G Poor <br />G Inadequate <br />COMMENTS; /l i f /iC —bitit C-HUlLliI/, jb— <br />h -3V <br />Date of Inspection Septic Sj^ai^m Inspector <br />Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function profierly. but is merely an opinion of the adequacy <br />of the system under current conditions based on the available infoimation. <br />This report must be kept on the premises with system location and pumping records. <br />WHITE COPY / Inspector*s File GOLD COPY / Homeowner
The URL can be used to link to this page
Your browser does not support the video tag.