Laserfiche WebLink
ON-SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />Oil the Ninth Shore of <br />Lake Minnetonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay. MN 55323 <br />473-7357 <br />OWNER ~divrLr::l T'.)re hr>\.ADDRESS ■1 I-1 \ cricl ^ I <br />PERMIT NO.'S.DATES ? -11 -CONTRACTORS a u <br />City Ordinance No. 210 reuuires that each on-site sewage treatment lystem in Orono be inspected on a tegular basis. The on-site sewage <br />treatment system at the above address has been inspected and appears to fall into the category checked below. <br />(This is □ an existing system □ new construction) <br />Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be oiMKating <br />properly. <br />Does not meet all current City standards for new construction (1978 Cjde) but in most respects appears to be designed, <br />located, and constructed general!v m accoroance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />Does not meet current City standards in many respects relating to design, construction, or locit>un. Appears to be oi>eraiing <br />adequately at this time, but has a relatively high potential for future (Troblems. No ma|or - s vadmg of system is required at <br />this time. <br />□ 2 <br />□ 3 <br />□ 4 System may or may not meet cuirent City standards for design, construction or location, but is failing to properly treat and <br />dispose of the current input, and is endangering a water suirply, or is a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacamant procedures. If drainfield replacement is necessary, soil testing will usually be requ.red, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION ( Q9 Checked items may require your action) <br />Tank inspection indicates <br />□ Pu*npout not needed at this time. <br />□ So. ds accumulation in tanks indicates they should be pump* <br />ad out this year to heip prevent future problems. <br />□ Solids accumuirtion in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />G System is discharging to surface. Tanks must be pumped <br />within 48 houis to eliminate surface discharge. <br />G Inspection risers missing-tanks couid not be inspected. <br />Inspection risers (4" die. pipe) must be instaifed in each tank <br />at rHixt pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the lasf three years, they <br />should be pumped out now. <br />DrMiMd inspection indica tes <br />G t)rainfield it dry, no surfacing evident. <br />□ Some evidence of surfacing, not critical yet. <br />□ Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace* <br />ment or additions to drainfield Contact the City Inspector <br />immediately. Repairs mutt be completed within 90 days. <br />G Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS <br />Limitir>g Site Factors <br />G Slops <br />G Soil <br />G High water table <br />G Lot size <br />G Lake, wetland, or stream <br />G Drainage <br />Potential for System Failure <br />(depends on soil typet'. water <br />table, and system condition) <br />la.Low <br />G Medium <br />Q High <br />G System is causing visible <br />surface discharge. <br />Site Capabilities for <br />F u^i^ E xpansion <br />/G Adequate <br />G Fair <br />D Poor <br />G Inadequate <br />COMMENTS <br />X // <br />Date of Inspection S^tic System IrtHTpdtor <br />1/ <br />Note: In the event that this inspection report is used to safsfy the requirements for a mortgage or otV- transfer of property, be advised that <br />thii does not guarantee or certify that an existing sysiem wiH continue to function proper^ , t it *s merely an opinion of the adequacy <br />of the system under current conditioru based on the evaiiable information. <br />This report must be kept on the premises with system location and pumping record* <br />WHITE COPY / Inspeciof t File GOLl ‘ / Homeoyymrr