1986-08-11 Mechanical Specifications
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1535 Bohns Point Road - 08-117-23-44-0025
>
Permits/Inspections
>
1986-08-11 Mechanical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2024 2:02:05 PM
Creation date
8/28/2024 1:59:22 PM
Metadata
Fields
Template:
x Address Old
House Number
1535
Street Name
Bohns Point
Street Type
Road
Address
1535 Bohns Point Road
PIN
0811723440023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />I . -- <br />! <br />■'i <br />’t' <br />I <br />:• ! <br />f <br />velocities to which they are subject. Where piping diameters <br />are smaller than the length of the wells, provide wells in <br />the piping at elbows to effect proper flow across the entire <br />area of the well; wells may either lOoK upstream or down <br />stream. Provide suitable thermal tranmission material within <br />the well to speed the response of temperature measurement. <br />Provide wells with sealing nuts to contain the thermal trans <br />mission material and allow for easy removal. Well shall not <br />restrict flow area to less than 70 percent of line-size pipe <br />normal flow area. <br />G. Pressure Sensors; Provide sensors in suitable NEMA enclosures <br />and provide sensors which are corrosion resistant throughout. <br />H. Indicators; Mount all temperature and pressure indicators <br />where they may be read by a person standing on the floor; <br />provide remote indicators where necssar.y to accomplish this. <br />3.02 ADJUSTMENTS <br />A. Adjust controls and equipment to maintain the conditions <br />indicated, to perform the functions indicated, and to operate <br />in the sequence specified. <br />3.03 INSTRUCTING OP'ilRATING PERSCNNEL <br />A. Upon completion of the work and at a time designated by the <br />Owner provide the services of a competent tecnhician re <br />gularly employed by the manufacturer of the temperature controls <br />for giving instruction to the Owner's personnel in the proper <br />operation and maintenance of each automatic space temperature <br />control system. The period of instruction shall be for not <br />less than two eight hour working days and as required by Owner. <br />3.04 NAMEPLATES <br />A. Provide laminated plastic nameplates for all control items <br />listed or shown in the submittal and approved control dia <br />grams. Each inscription shall identify its function; such <br />as "mixed air controller", "cold deck sensor", and when <br />applicable its position. Laminated plastic shall be 0.125 <br />inch thick Melamine plastic, black with white center core. <br />Surface shall be matte finish. All corners shall be square. <br />The lettering shall be accurately -aligned and engraved into <br />the white core. Size of nameplates shall be one by 2.5 <br />inches minimum. Lettering shall be minimum 0.25 inch high <br />normal block lettering. Key nameplates to a chart cind schedule <br />for each system. Mount charts and schedules under glass, in <br />a frame and place where directed near each system. Furnish <br />two copies of each chart and schedule to the prior to final <br />acceptance. <br />END OF SECTION <br />M-If ^ <br />15900-9
The URL can be used to link to this page
Your browser does not support the video tag.