My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1986-08-11 Mechanical Specifications
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1535 Bohns Point Road - 08-117-23-44-0025
>
Permits/Inspections
>
1986-08-11 Mechanical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2024 2:02:05 PM
Creation date
8/28/2024 1:59:22 PM
Metadata
Fields
Template:
x Address Old
House Number
1535
Street Name
Bohns Point
Street Type
Road
Address
1535 Bohns Point Road
PIN
0811723440023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />II. «r <br />%\» . * <br />1. Duct sleeves and closure collars: Fabricate from 20 <br />gauge galvanized steel. Where sleeves are installed <br />in bearing walls or partitions use blaclc steel pipe, <br />standard weight, instead. <br />2. Prepared Openings: Provide one-inch clearance between <br />the duct and the sleeve. <br />B. Deflectors: Factory-fabricated and factory-or-field assembled <br />units consisting of curved turning vanes for uniform air <br />distribution and change .of direction with minimum turbulence <br />and pressure loss. Provide curved vanes for square elbows. <br />C. Access Doors: Door frame shall be welded in place. Door <br />shall be rigid and airtight with neoprene gaskets and two <br />or more galvanized steel hinges and tension fasteners. <br />Provide doors as large as practical. Mount doors, if pos <br />sible, so that air pressure holds then closed. <br />D. Panels: Where motorized dampers, fire dampers, control <br />equipment, etc., are installed in ducts, provide access panels. <br />Makre airtight with gasketed edges. Use Ventlok sponge rub <br />ber or felt gasketing material. The panels shall be attached <br />to the duct with cam latches. The access panels shall be <br />of adequate size to permit maintenance of the equipment. <br />This Contractor has the option of furnishing prefabricated <br />access doors of identical construction characteristics as <br />specified above. <br />E. Dampers and louvers shall be two gauge heavier than ducts <br />in which installed. Dampers shall be opposed blade type. <br />The construction shall be of aluminum or galvanized steel <br />with interlocking edges and maximum 10 inch blade width, <br />conform with SMACWA. Quadrants shall be marked to indicate <br />damper position. <br />1. Backdraft Dampers (Gravity Dampers or Shutters): Factory- <br />fabricated with delicately balanced blades that open <br />automatically when the ventilator fan starts and close <br />by gravity when the fan stops. Provide the edges of <br />blades with felt or rubber strips to prevent rattling. <br />2. Splitter and Manual Volume Dampers; Balancing, factory- <br />fabricated type. Equip dampers with accessible mechanism <br />suich as quadrant operators chains or 3/16 inch rods <br />brought through the side of ducts with locking set screw <br />and bushing. Where operators occur in finished portions <br />of the building, operators shall be chrome-plated with <br />all exposed edges rounded. <br />3. Automatic Dampers: Section 15900 "Controls and Instrumen <br />tation" . <br />a. Control dampers to be supplied and installed by <br />Mechanical Contractor. Damper operators by Control <br />Contractor. <br />4. Bird Screens: Bird screens shall be 1/2" by 1/2" mesh, <br />0.63" diameter aluminum wire or 0.013" diameter stain <br />less steel wire. Insect screen frames shall be grooved <br />15840-4