1986-08-11 Mechanical Specifications
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1535 Bohns Point Road - 08-117-23-44-0025
>
Permits/Inspections
>
1986-08-11 Mechanical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2024 2:02:05 PM
Creation date
8/28/2024 1:59:22 PM
Metadata
Fields
Template:
x Address Old
House Number
1535
Street Name
Bohns Point
Street Type
Road
Address
1535 Bohns Point Road
PIN
0811723440023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />I - <br />W s <br />-t <br />'J <br />c. <br />A. <br />B. <br />D. <br />Machinery Guards; Fully guard drive mechanisms and other <br />moving parts. Provide guards fabricated of steel and ex <br />panded metal, rigidly mounted and readily removed without <br />disassembly. <br />D. Submit Manufacturer's Data; <br />1. <br />2. <br />3. <br />4. <br />3. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />Dampers <br />Sound Attenuators and Attenuator Ducts <br />Acoustical Duct-lining <br />Flexible Ducts <br />Insulation and Vapor Barrier <br />Cooling Coils <br />Roof Curbs <br />Louvers <br />Louvered Penthouse <br />Air Filters <br />Eliminators <br />Drip Pans <br />Bird Screens <br />Diffusers, Registers and Grilles <br />Manometers, etc. <br />E. Submit standards compliance and miantenance manuals fort <br />1. <br />2. <br />Cooling Coils <br />Filters <br />PART 2 - PRODUCTS <br />2.01 FLEXIBLE DUCTWORK - LOW PRESSURE <br />Flexible duct for connections to diffusers, to registers <br />or air bonnets if used with prior approval shall be made <br />with factory preinsulatad duct composed of a corrosion- <br />resistant reinforcing wire heli.x permanently bonded and <br />enclosed in Tedlar film, then covered with 1" thick 3/4 <br />lb. density fiberglass insulation blanket sheathed in a <br />vapor barrier laminated to glass mesh. <br />Ductwork must comply with latest NFPA Bulletin 90A and be <br />tested as Class 1 Air duct material, UL Standard 181. <br />C. Engineering data shall be as follows; <br />1. <br />2. <br />K Factor; <br />Vapor Barrier Permeance: <br />60°F <br />3. <br />4. <br />5. <br />6. <br />Temperature Range; <br />UL Raged Velocity: <br />Flame Spread: <br />Smoke Developed: <br />29 of <br />.30 GR/24 hr/M sq./MN hq <br />per ASTM Method E96, <br />Procedure ^ <br />0''F to 180 <br />4000 fpm <br />not over 25 <br />not over 50 <br />Acceptable manufacturers of flexible insulated ducts assem <br />bly shall be Ownes-Corning Fiberglass, Glas.« Flex type <br />OC-41 or Thermaflex type M-KA. <br />I <br />15840-2
The URL can be used to link to this page
Your browser does not support the video tag.