My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1986-08-11 Mechanical Specifications
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1535 Bohns Point Road - PID: 08-117-23-44-0025 - New PID
>
1535 Bohns Point Rd - PID: 08-117-23-44-0023 - Old PID
>
Permits (2)
>
1986-08-11 Mechanical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2024 2:02:05 PM
Creation date
8/28/2024 1:59:22 PM
Metadata
Fields
Template:
x Address Old
House Number
1535
Street Name
Bohns Point
Street Type
Road
Address
1535 Bohns Point Road
PIN
0811723440023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
‘j <br />r <br />j <br />'ll <br />r • <br />! <br />w <br />3.01 <br />A. <br />B. <br />C. <br />A. <br />A. <br />B. <br />C. <br />D. <br />PART 3 - EXECUTION <br />PIPE AND FITTINGS <br />Piping shall be run substantially as shown on the drawings <br />Adjustments to locations shall be made where necessary to <br />accommodate interferences made apparent in the field. <br />Make all reductions in pipe size with eccentric or concentric, <br />as appropriate, reading fittings to allow for complete gravity <br />draining of lines. Use no bushings. All pipe nipples shall <br />be of the same material as lines in which they occur. Mini> <br />mum size of water piping shall be 1/2" except within 12" of <br />fixture. <br />Piping shall be installed and valved to provide for complete <br />drainage through drain cocks. All pipe runs shall be straight <br />and with uniform pitch. Support all piping adequately to <br />prevent sag and pocketing. <br />1. <br />2. <br />3. <br />Concealed Piping. All piping buried underground or con <br />cealed in walls, ceilings, conduit or chases must be <br />inspected and approved by the Engineer before being <br />covered or enclosed. <br />Exposed Piping. Install exposed piping as close to ceilings <br />and beams as possible, maintaining highest possible head- <br />room consistent with the correct pitching of the pipe. <br />Gas Piping. Install all gas piping in accordance with <br />the local gas company's, AGA's and State's minimum standard <br />- see piping connections inside the building. 1-1/2" and <br />'arger shall be made only with welded joints. <br />3.02 PREPARATION <br />Ream pipes and tubes. Clean off scale and dirt, inside and <br />outside, before assembly. Remove welding slag or other <br />foreign material before piping. <br />3.03 CONNECTION <br />Screw joint steel piping up to and including 2 inc... ' . <br />piing 2-1/2 inch and larger, including branch connection^ <br />Make screwed joints with full cut standard taper pipe threads <br />with red lead and linseed oil or other approved non-toxic <br />joint compound applied to male threads only. <br />Jointh for cast iron bell and spigot pipe: (lead and oakum) <br />(neoprene gasketing system). <br />Clamp cast iron water pipe at fittings with 3/4 inch rods <br />and properly anchor and support. <br />15060-4
The URL can be used to link to this page
Your browser does not support the video tag.