Laserfiche WebLink
Elmnbipg <br />7. Clean out plugs not provided - MN Plumbing Code Section 4715.0220. <br />8. Floor Drain: provide for over flow of water heater. <br />9. Water Heater: ,.jt accessible. <br />10. T i P Relief Value: must be extended within 18" of floor. <br />11. Shut Off Valves: could not find shut off valve for water heater. <br />Heating Svstem <br />12. Type of Unit: Gas Forced Air, Sears, undersized for dwelling <br />unit,. Wood - Ben Franklin, improperly installed. <br />13. Flue Vent Pipe & Connections: forced air - shut off valves are <br />missing - Wood Stove: improper clearances to combustible; some <br />charring at wall; and unit is placed on combustible floor. <br />RBAR/SIDB ENTRY <br />14. Floor; wood (porch area) exposed to weather - untreated wood - <br />UBC 1707 (a). <br />15. Walls: in deteriorated condition - UBC 1707 (a). <br />16. Ceiling: in deteriorated condition - UBC 1707 (a). <br />KITCHEN <br />17. Exterior Door: blocked and not used. <br />18. Electrical: Light not provided - switch not provided. <br />19. Receptacles: cutlet not provided on counter tops - NFPA 70 Art <br />210-52 (b). <br />Elambing <br />20. Vent: plumbing vent not provided <br />Section 4715.0220. <br />- MN State Plumbing Code <br />21. Stove: gas shut off not provided <br />Conditioning Code Section 1345.2670. <br />- MN Heating, Ventilating, Air <br />Page 2 of 8 <br />I