Laserfiche WebLink
BEDROOM #1 <br />42. No smoke detector provide - UBC 1210 (a). <br />43. Windows: fire egress window not provided per UBC 1204. <br />44. Electrical: ceiling light not operable. <br />41. Receptacles: outlets over 6’ apart. <br />bedroom #2 - ATTIC <br />- UBC4:. Attic: used for bedroom - ceiling height not acceptable <br />1207 (a). <br />43. insulation: observed from exterior - sncw melting off roof very <br />fast - sign of poor insulation. <br />44. Stairway: 2nd floor - improper guardrail height. <br />EXTERIOR <br />45. Ground Slope at Foundation: slopes toward structure. <br />46. Siding: weathered and deteriorating UBC 1707 (a). <br />47. Soffit s Fascia: deteriorating - UBC 1707 (a). <br />4S. Roof Ventilation: inadequate ventilation - only top ventilation <br />provided — UBC 3205 (c). <br />49. Garage: deteriorating. <br />Building is in a state of deterioration and dilapidation, th^is it <br />is a safety and health hazard pursuant to Minnesota State Building <br />Code/Uniform Building Coder Section 203. <br />Page 4 of 8