My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
04/19/2024 septic
Orono
>
Property Files
>
Street Address
>
L
>
Luce Line Ridge
>
80 Luce Line Ridge - 31-118-23-34-0010
>
Septic
>
04/19/2024 septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2024 12:41:26 PM
Creation date
4/29/2024 12:41:23 PM
Metadata
Fields
Template:
x Address Old
House Number
80
Street Name
Luce Line
Street Type
Ridge
Address
80 Luce Line Ridge
PIN
3111823340010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manufacturer: Consolidated Treatment Svstems Model: Multi -Flo FTP-0.6 <br />This component was: <br />Fully Inspected <br />Unit alarms functioning: <br />YES <br />Aerobic Mechanism appears to be functioning per manufacturers specifications: <br />YES <br />Impeller assembly removed and cleaned: <br />NO <br />Previous signs of foaming overflow noted on Weir Plate: <br />NO <br />Filter Socks cleaned: <br />YES <br />Filter Socks were partially changed out: <br />NO <br />Filter Socks were completely changed out: <br />NO <br />Gaskets on Sure Bowl need replacing: <br />NO <br />Digester settleable solids test resulted in greater than 40% settleable solids: (If Yes, pumping needed) <br />NO <br />Pum in needed: <br />TANK: Septic Tank - 1 Compartment 1000 Gal Dose Tank <br />NO <br />This component was: <br />Fully Inspected <br />Effluent level within operational limits if NO explain in comments): <br />YES <br />All required baffles in place N/A= No baffles required): <br />YES <br />Compartment 1 Scum accumulation Inches, if otherspecify): <br />0 <br />Compartment 1 Sludge accumulation Inches, if others ecif : <br />0 <br />Pumping recommended: <br />Pump: Effluent . Dose Pump <br />NO <br />This component was: <br />Fully Inspected <br />Controls functioning: <br />YES <br />Tested allons er minute flow: <br />PumpsPanel: Control - 2 This component was: <br />Fully Inspected <br />Panel functioning (including alarm): <br />YES <br />Pump 1: on minutes override in parentheses - if present): <br />20 sec <br />Pump 1: off hours override in parentheses - if present): <br />30 min <br />Pump 1: gallons per dose override in parentheses - if present): <br />Pump 1: ETM hours override in parentheses - if present): <br />Pump 1: Cycle Count override in parentheses - if present): <br />Pump 2: on minutes override in parentheses - if present): <br />Pump 2: off hours override in parentheses - if present): <br />Pump 2: gallons per dose override in parentheses - if present): <br />Pump 2: ETM hours override in parentheses - if present): <br />NA <br />Pump 2: Cycle Count override in parentheses - if present : <br />Drainfield (disposal): Pressure Bed Drainfield <br />NA <br />This component was: <br />Fully Inspected <br />Lateral lines flushed: <br />NO <br />Average squirt height ifperformed) feet, if otherspecify): <br />Ponding present? If YES explain in comments: <br />NO <br />This report indicates certain characteristics of the onsite sewage system at the time of visit. In no way is this report a guarantee of operation or future performance. <br />ReportlD: 1280773 View inspection reports online at www.onlinerme.com Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.