Solar permit summary, plan and final inspection
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
2380 Watertown Rd - 34-118-23-33-0080
>
Permits/Inspections
>
Solar permit summary, plan and final inspection
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2024 2:45:32 PM
Creation date
3/25/2024 2:45:18 PM
Metadata
Fields
Template:
x Address Old
House Number
2380
Street Name
Watertown
Street Type
Road
Address
2380 Watertown Rd
Document Type
Permits/Inspections
Permit Number
SES22-000001
PIN
3411823330080
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROJECT INFOSHEET NUMBERSCALESTACEY WILSON2380 WATERTOWN RDLONG LAKE, MN 55356SHEET NAMEDATE3.5.2024POWERFULLY GREEN2010 E HENNEPIN AVE.,MINNEAPOLIS, MN 55413COVER PAGENTSAPPLICABLE CODES & STANDARDSSTRUCTURAL CRITERIA1.WIND EXPOSURE CATEGORY: C2.WIND SPEED: 109.0 MPH3.GROUND SNOW LOAD: 50.0 PSF10.78 KW DC & 7.6 KW AC PV SOLAR ARRAYPV MODULES - 28 JINKO SOLAR JKM385M-6RL3-BINVERTER(S) - 1 GENERAC PWRCELL 7.6KW XVT076A03ROOF TYPE - ASPHALT SHINGLESRACKING - SNAPNRACK UR-40ATTACHMENT - SNAPNRACK ULTRA RAIL SPEEDSEAL FOOTGOVERNING CODES1.ALL WORK SHALL COMPLY WITH:1.1.2017 NATIONAL ELECTRICAL CODE1.2.2018 INTERNATIONAL BUILDING CODE1.3.2018 INTERNATIONAL FIRE CODE1.4.2018 INTERNATIONAL RESIDENTIAL CODE1.5.2018 INTERNATIONAL EXISTING BUILDING CODE1.6.AND ALL OTHER STATE AND LOCAL AMENDMENTSTO BUILDING AND ELECTRICAL CODESXCEL ENERGY MN NOTES1.24/7, UNESCORTED, KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL EQUIPMENT.2.THERE ARE NO NESC CLEARANCE CONCERNS IN RELATION TO XCEL OWNED FACILITIES.3.THE UTILITY AC DISCONNECT SHALL BE LOCATED IN A READILY ACCESSIBLE LOCATION WITHIN 10' OF THEMAIN SERVICE METER.4.PHASES OF DER SYSTEM BASED ON THE INVERTER OUTPUT (1-PHASE 3-WIRE).5.ALL REQUIRED ELECTRICAL LABELS ARE SHOWN ON PV-56.A PLACARD IS REQUIRED AT THE MAIN BILLING METER WITH YELLOW & BLACK LETTERING STATING,"PHOTOVOLTAIC SYSTEM CONNECTED." (ALSO SHOWN ON PV-5).UTIL - XCEL ENERGY MNAHJ - ORONO (CITY)OCCUPANCY - IICONSTRUCTION - SFRZONING - RESIDENTIALSCOPE OF WORKINSTALLATION OF ROOF-MOUNTED UTILITY INTERACTIVE PV SYSTEMGENERAL NOTES1.THIS PROJECT INVOLVES THE INSTALLATION OF A GRID-INTERACTIVE PV SYSTEM. PV MODULES WILL BEMOUNTED USING A PRE-ENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED TOTHE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCALUTILITY AND AUTHORITY HAVING JURISDICTION.2.THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGHDETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALLNOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THESYSTEM SHALL COMPLY WITH ALL MANUFACTURER INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLECODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. THECONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT.3.THIS DOCUMENT IS BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUALFIELD CONDITIONS MAY VARY AND REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS.4.THE DIMENSIONS AND MEASUREMENTS SHOWN IN THIS DOCUMENT ARE BASED ON AERIAL IMAGERY AND OTHERAVAILABLE INFORMATION, AND ARE TO BE TREATED AS APPROXIMATED TO SHOW A GENERAL IDEA OFEQUIPMENT LOCATION AND PROPERTY SIZE.5.ANY CHANGES TO THIS DESIGN AT THE TIME OF INSTALLATION DUE TO FIELD CONDITIONS MUST BE REPORTEDTO THE DESIGNER AND AHJ.SHEET INDEXPV-1 COVER PAGEPV-2 SITE PLANPV-2AROOF PLANPV-3 ATTACHMENT DETAILSPV-4 THREE LINE DIAGRAMPV-5 ELECTRICAL LABELSPV-5A SITE PHOTOSPV-6+ SPEC SHEETSELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION2.ALL RACEWAYS ON ROOFTOPS SHALL BE PLACED MORE THAN 7/8" ABOVE THE ROOFTOP. ALLCONDUCTORS SHALL BE COPPER, RATED FOR 600V AND 90°C WET ENVIRONMENT3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, ANDLOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITHNEC 110.265.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS6.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS, AND ACCESSORIES TOFULFILL APPLICABLE CODES AND STANDARDS7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUCTORS ARE NOT SPECIFIED, THECONTRACTOR SHALL SIZE THEM ACCORDINGLY8.ARRAY GROUNDING TO BE INSTALLED PER RACKING MANUFACTURER'S INSTRUCTION9.ARRAY RACKING TO BE BONDED WITH CONTINUOUS COPPER E.G.C. VIA WEEB LUG OR ILSCO GBL-4DBTLAY-IN LUG10.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE.11.SURGE PROTECTION REQUIRED PER NEC 230.67PV-1AERIAL VIEWReviewed for Code ComplianceNicole PostSES24-0000013-7-24Additional permits required:ElectricalStamped and approvedplans must be on site forthe duration of the projectand all inspections.To schedule inspections call: 952-249-4613Please have the permit number andstreet address ready at time of call.
The URL can be used to link to this page
Your browser does not support the video tag.