My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic as built Survey
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
800 Lakeview Parkway - 06-117-23-43-0020
>
Septic
>
Septic as built Survey
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2024 10:02:03 AM
Creation date
2/28/2024 10:00:40 AM
Metadata
Fields
Template:
x Address Old
House Number
800
Street Name
Lakeview
Street Type
Parkway
Address
800 Lakeview Pkwy
Document Type
Septic
PIN
800
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
❑ WELL setbacks: 20'- 50' to sewer line req's MDH pressure test form (5 psi for 15 min) <br />50' to everything 100' to drainfield with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE/ BLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE _. Protected wetland <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure 10' to bed,tank a sewer line. (else sewer line > 12" below) <br />Sewer line £t tank connection (no hard 90's, long sweep 90 or 2-45's, slope minimum 1" in 8' = 1%) <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight risers, baffles, insulated, proper depth, existing verified by pumping) <br />Mfg _ 2250 gallons Multiple tanks or compartments req'd <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Ft alarm <br />Dose tank, risers and piping (water tight risers, insulated, proper depth, drainback) <br />mfg _ 1250 gallons <br />Optional Time dosing of: <br />dose pump _ 36 gpm 23 head VERIFY PUMP CURVE 5.5 min ON 8.5 hr OFF <br />verify that installed "vertical lift from pump to laterals" is no more than design value of 15 feet <br />float setting drop 7.7 inches at 25.5 gpi "DESIGNED" 4.9 inches approx float tether length <br />197.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections / Hi Level Alarm <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 63.0 <br />Sand lift depth 22 inches. (Jar test : 2" sand leaves < 1/8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope 10.0 downslope <br />Bermed topsoil beyond rockbed 10 upslope 14 sideslope 21 downslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe Et fittings) <br />3.0 ft lateral spacing <br />H7/32 inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary �Re-use existing tank certification <br />monitoring plan and type <br />well abandonment form - if necessary <br />Y Y <br />