Laserfiche WebLink
PLAN REVIEW NOTES <br />Chufch/Day Care <br />A 2.1 Occupancy - Sancmar/ <br />- 3,207 s.f. ± divided b'' = 458 occupants <br />- 2 exits required - A jposed <br />- distance to exits okay <br />- 9 ’ of exit width required - 18’ proposed <br />E-3 Occupancy - Day Care/Classroom <br />- 684 s.f.+. divided by 20 = 34 occupants <br />- 1 exit required - 3 proposed <br />- 3’ exit width required - 9 ’ proposed <br />B-2 Occupancy - Offices <br />- 734 s.f.± divided by lOO -• 7 occupants <br />- exiting okay <br />Type of Construction <br />Type V - one hour required <br />Type proposed - not shown <br />Location on Property <br />2 hour walls required less than 10’ <br />1 hour walls required less than 40’ <br />Survey shows 48’ + to propert>- lines <br />Allowable Floor Area <br />10,500 allowed - 6,146 ±, proposed <br />Sanitation <br />Required number of water closets + lavatories okay <br />1 water fountain required <br />All equipment must be handicap accessible <br />L-' <br />Comments <br />- Sprinkler system must be extended throughout new addition <br />- An approved fire alarm system tied into the sprinkler system must be provided <br />- E.xits from activity/sanctuaiy must be provided with panic hardware <br />- Exit corridors from activity/sanctuary must be of 1 hour construction, doors must <br />have 20 min. rating