24'-6"NEW ADDITIONEXISTING EXST'GEXST'GEXST'G18"d ROOM-IN ATTICROOF TRUSS @ 24" O.C. <br />18"d ROOM-IN ATTIC <br />ROOF TRUSS @ 24" O.C. <br />VERIFY EXST'G <br />NEW24'-0"24'-0"4'-0"16'-0"4'-0"(3)2'-6"x4'-0"NEW GIRDER TRUSSROOF TRUSSES@ 24" O.C.(3) 2x10's(HDR)(2) 2x10's(HDR)(2)2'-6"x4'-0"(2) 2x10's(HDR)18"d ROOM-IN ATTICROOF TRUSS @ 24" O.C.NEW GIRDER TRUSS 6'-6 1/4"( VERIFY & MATCH WIDTH OF EXST'G)10'-11 1/2"6'-6 1/4"(3)2'-6"x4'-0"6'-9" WALL HT.6'-9" WALL HT.6'-9" WALL HT.6'-9" WALL HT.NEW ADDITION EXISTING3" / 12"3" / 12"10" / 12"10" / 12" <br />3" / 12"3" / 12" <br />10" / 12"10" / 12" <br />10" / 12"10" / 12" <br />VERIFY EXST'GVERIFY EXST'G <br />VERIFY EXST'GVERIFY EXST'G <br />VERIFY EXST'GVERIFY EXST'GMATCH EXST'G MATCH EXST'GMATCH EXST'GMATCH EXST'G <br />Garage Floor0' - 0"8" CONC FNDN WALL24" X 8" d CONT. STRIP8"4'-0"SEE STRUCTURL FOR REINFORCINGAND SCREW ANCHOR INFORMATION12" CONC FNDN WALL24" X 12" d CONT. STRIP4'-0"1'-0"6"8"SEE STRUCTURL FOR REINFORCINGAND SCREW ANCHOR INFORMATION5" STRUCTURAL SLAB; SEE STRUCTURAL FOR REINFORCING6 MIL POLY VAPOR BARRIER w/ 12" LAP OVER 4" CLEAN GRANULAR FILLOFFICE: (952) 746-7702 | FAX: (952) 746-7703 <br />CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE: <br />DRAWN BY: <br /> c 2023 BEHR DESIGN, INC. <br />THIS DRAWING AND DESIGN LAYOUT IS <br />PROTECTED UNDER STATE AND FEDERAL <br />COPYRIGHT LAWS. IT MAY NOT BE <br />REPRODUCED OR USED FOR ANY <br />PURPOSE WITHOUT PRIOR WRITTEN <br />CONSENT FROM BEHR DESIGN, INC. <br />PROJECT FILE: <br /> BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS <br />AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, <br />LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS <br />SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED <br />ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A <br />SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED <br />OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. <br /> THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, <br />DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO <br />ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT <br />TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL <br />FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE <br />COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.A3Floor & Roof PlansBrent Walton Residence <br />2405 Dunwoody Avenue <br />Orono, MN <br />las <br />10/17/2023 <br />23-CLNOTES:1.) ALL BRG. HEADERS ARE TO BE (2)-2x10 UNLESS NOTED OTHERWISE (UNO).2.) OWNER/CONTRACTOR TO VERIFY ALL WINDOW & DOOR SIZES.3.) OWNER/CONTRACTOR TO SPEC. ALL FLOORING MATERIAL.4.) OWNER/CONTRACTOR TO VERIFY ALL DIMENSIONS.5.) ALL BRG WALL WINDOW & DOOR OPNG'S WIDER THAN 60" REQUIRE (2) TRIMMERS MIN. UNDER EA. SIDE OF HEADER.6.) (FL) - FLUSH BEAM, (DR) DROPPED BEAM7.) ALL HEADERS ARE DROPPED UNLESS NOTED (FL)8.) USE ENERGY HEEL HEIGHT ON ROOF TRUSSES.PRELIMINARYNOT FOR CONSTRUCTION(FOR BIDDING PURPOSES ONLY) 1/4" = 1'-0"A31UPPER FLOOR PLAN 1/8" = 1'-0"A32Roof Plan 1/2" = 1'-0"A33Cross Section @ Foundation74
The URL can be used to link to this page
Your browser does not support the video tag.