3. Inlet Threads: [1” NPT][ISO7-1R1][3/4” NPT][ISO7- <br />1R3/4] <br />4. Inlet Fitting: [Long – Standard Inlet Fitting][Short “PL” <br />– Wet Pipe Systems only] <br />5. Sprinkler Temperature Rating: See Temperature Rat- <br />ings table <br />6. Sprinkler Finish: See Finishes Table <br />7. Escutcheon/Cover Plate Finish: See Finishes Table <br />8. Length: <br />*For dry pendents and dry sidewalls: “A” Dimen- <br />sion is from face of tee to face of finished ceiling or <br />wall in 1/4” (6mm) increments. See Fig. 1 through <br />Fig. 9. <br />*For dry uprights: Order dimension is from face of <br />tee to top of deflector in 1/4” (6mm) increments. <br />See Fig. 10. <br />Notes: <br />1. For Dry Upright, customer is responsible for determining <br />the correct deflector distance from structure above. <br />2. Length is based on normally gauged pipe thread “make- <br />up” of .600” (15mm) per ANSI B2.1 (approximately 7-1/2 <br />threads). <br />Reliable Automatic Sprinkler Co., Inc. <br />(800) 431-1588 Sales Offices <br />(800) 848-6051 Sales Fax <br />(914) 829-2042 Corporate Offices <br />www.reliablesprinkler.com Internet Address <br />Manufactured by <br />Recycled <br />Paper <br />Revision lines indicate updated or new data. <br />EG. Printed in U.S.A. 04/20 P/N 9999970175 <br />The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory <br />Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. <br />Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. <br />Installation Data <br />Sprinkler <br />Model Escutcheon or Cover Plate Suggested Hole Diameter <br />in Wall or Ceiling <br />Installation <br />Wrench <br />Required Centerline of Sprinkler <br />Tube/Inlet to Finished Ceiling <br />Vertical Dimension* <br />F3QR56 Dry <br />Pendent <br />Standard Escutcheon 2-1/8” (54 mm)F3R <br />Not <br />Applicable <br />HB Extended Escutcheon 2-1/2” (64 mm)F3R <br />F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 <br />FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 <br />CCP Cover Plate XLO2 <br />F3QR56 Dry <br />Horizontal <br />Sidewall <br />Standard Escutcheon 2-1/8” (54 mm)F3R 4-5/8” to 12-5/8” <br />(118 mm to 321 mm)HB Extended Escutcheon 2-1/2” (64 mm)F3R <br />F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 cULus, NYC <br />4-5/8” to 6-5/8” <br />(118 mm to 168 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 <br />F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 FM <br />4-5/8” to 12-5/8” <br />(118 mm to 321 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 <br />F3QR56 Dry <br />Upright N/A 1-1/2” (38mm)F3R Not Applicable <br />*Note: Based on 5/8” (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. <br />Maintenance <br />The Model F3QR56 Dry Sprinklers should be inspected <br />and the sprinkler system maintained in accordance with <br />NFPA 25. Do not remove the factory applied thermally sen- <br />sitive wax fillet between the bulb supporting cup and the <br />wrenching boss. Do not replace this wax with a substitute <br />substance. <br />An Alternate substance may interfere with proper operation <br />of the sprinkler. Do not clean sprinklers with soap and water, <br />ammonia or any other cleaning fluids. Remove dust by us- <br />ing a soft brush or gently vacuuming. Replace any sprin- <br />kler which has been painted (other than factory applied) or <br />damaged in any way. A stock of spare sprinklers should be <br />maintained to allow quick replacement of damaged or op- <br />erated sprinklers. Prior to installation, sprinklers should be <br />maintained in the original cartons and packaging until used <br />to minimize the potential for damage to sprinklers that would <br />cause improper operation or non-operation. <br />Ordering Information <br />Specify: <br />1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] <br />[Model F3QR56 Dry Horizontal Sidewall SIN R5734] <br />[Model F2QR Dry Upright SIN R5724] <br />2. Escutcheon/Cover Plate: [None][Standard escutch- <br />eon][Model HB extended escutcheon][Model F1 re- <br />cessed escutcheon][Model FP recessed escutcheon] <br />[Model CCP cover plate – pendent only]