Laserfiche WebLink
REV DESCRIPTION <br />ISSUE DATE ISSUED FOR <br />02 8/22/23 Variance Submission <br />All ideas, designs, plans and specifications are <br />the property of The Landschute Group, Inc.  This <br />copyrighted plan is an instrument of service to <br />be used only by Landschute as it constructs the <br />project for its client. Any other use is <br />unauthorized and strictly prohibited (without <br />Landschute’s express written permission) and <br />subject to copyright protection under Section <br />102 of the Copyright Act, 17 U.S.C., as <br />amended December 1, 1990, known as the <br />Architectural Works Copyright Protection Act of <br />1990. Protection includes but is not limited to <br />overall form as well as the arrangement of <br />spaces and details of the design.  Under such <br />protection, unauthorized use of these plans, or <br />works resulting from these plans,  can result in <br />the termination and loss of such construction as <br />well as fines up to $100,000 per offense. <br />A0.02 <br />Symbols & General Notes <br />SHEET NAME <br />SCALE AS INDICATED <br />202 Water St. #202 <br />Excelsior, MN 55331 <br />(952) 470-7416 <br />Builder License: BC002303 <br />© 2023 <br />ARCHITECT & BUILDER <br />COPYRIGHT NOTICE <br />PROJECT <br />CURRENT REVISIONS <br /> ISSUE HISTORY <br />PRINTED DATE: 8/22/23 <br />DRAWN BY: ELH <br />HULL RESIDENCE <br />PROJECT ADDRESS <br />2245 French Lake Road <br />Orono, MN 55391 <br />New Home <br />CLIENT NAME <br />Leigh and John Hull <br />CL <br />ABBREVIATIONS SPECIAL SYMBOLS <br />& And <br />@ At <br />x By <br /> Centerline <br />° Degrees <br />' Feet <br />" Inches <br />% Percent <br /># Pounds/Number <br />+/- Plus or Minus <br />A.B. Anchor Bolt <br />A/C Air Conditioning <br />ADJ. Adjustable <br />AFF Above Finished Floor <br />AFG Above Finished Grade <br />AHJ Authority Having Jurisdiction <br />APPROX. Approximate <br />ARCH. Architectural <br />BD Board <br />B.I. Built-In <br />BIT. Bituminous <br />BLDG Building <br />BLKG Blocking <br />BM Beam <br />B.O.F. Bottom of Footing <br />B.O.W. Bottom of Wall <br />B.W.L. Braced Wall Line <br />CAB Cabinet <br />CANT Cantilevered <br />C.C. Center to Center <br />CL Centerline <br />CIP Cast-In-Place <br />CMU Concrete Masonry Unit <br />CONC Concrete <br />CONT Continuous <br />DBL Double <br />DIM Dimensions <br />DR Door <br />DN Down <br />DW Dishwasher <br />EA Each <br />ELEC Electrical <br />EQ Equal <br />EW Each Way <br />EXC Excavate <br />EXT. Exterior <br />FCO Floor Cleanout <br />FD Floor Drain <br />FDN. Foundation <br />FFE Finished Floor Elevation <br />FG Finished Grade <br />FL Floor Level <br />FRPF Fireproof <br />FT Feet <br />FTG Footing <br />FURN Furnace <br />GYP Gypsum <br />H.B. Hose Bib <br />HVAC Heating, Ventilating, <br /> and Air Conditioning <br />JST Joist <br />IBC International Building Code <br />IN Inches <br />INSUL Insulation <br />INT Interior <br />IRC International Residential Code <br />LH Left Hand <br />LSL Laminated Strand Lumber <br />LVL Laminated Veneer Lumber <br />Mech. Mechanical <br />M.O. Masonry Opening <br />MSBC Minnesota State Building Code <br />MSRC Minnesota State Residential <br /> Code <br />O.C. On Center <br />PL Property Line <br />PLF Per Lineal Foot <br />P.S.I. Pounds per Square Inch <br />P.T. Pressure Treated <br />R Radius <br />REBAR Reinforcing Bar <br />REFR Refrigerator <br />REINF Reinforced <br />REQD Required <br />RH Right Hand <br />RM Room <br />R.O. Rough Opening <br />SB Steel Beam <br />SC Steel Column <br />SD Smoke Detector <br />SF Square Feet <br />Specs. Specifications <br />SQ Square <br />SL Spring Line <br />SIM. Similar <br />T&G Tongue & Groove <br />T.O.B. Top of Beam <br />T.O.C. Top of Curb <br />T.O.F. Top of Footing <br />T.O.H. Top of Heel <br />T.O.J. Top of Joist <br />T.O.M. Top of Masonry <br />T.O.W. Top of Wall <br />TRTD Treated <br />TYP. Typical <br />U.N.O. Unless Noted Otherwise <br />W/ With <br />W.C. Water Closet (Toilet) <br />W.H. Water Heater <br />W.I.C. Walk-In Closet <br />W/O Without <br />W.S. Water Softener <br />YDS Yards <br />X <br />N <br />X <br />1 <br />A-101 <br />1 <br />A-101 <br />1 <br />A-101 <br />1 <br />A-101 <br />XX <br />X STORY <br />0'-0" <br />X STORY <br />0'-0" <br />SECTION MARKER <br />Sheet Reference Number <br />Drawing Reference Number <br />Sheet Reference Number <br />Drawing Reference Number <br />ELEVATION MARKER <br />DETAIL MARKER <br />Sheet Reference Number <br />Drawing Reference Number <br />REVISION MARKER <br />Revision Number <br />(Refer to Revision Log) <br />LEVEL MARKER <br />Reference Level <br />Elevation (Main Level = 0'-0") <br />WINDOW LABEL <br />Window ID <br />DOOR LABEL <br />NORTH ARROW <br />Nominal Door Slab Width <br />Nominal Door Slab Height <br />JOIST LABEL <br />Joist Type <br />Joist Orientation <br />BEAM LINE <br />Beam Type <br />BEARING POST <br />Bearing Post <br />(Type & Size Varies) <br />CEILING HEIGHT <br />Ceiling Height <br />(Rough Framing) <br />X <br />X <br />X'-X"X'-X"X'-X"X <br />Door ID <br />Direction of True North <br />Joist Spacing <br />ENLARGED PLAN MARKER <br />Sheet Reference Number <br />Drawing Reference Number <br />ELEMENT ABOVE <br />Element Above <br />Floor Plan Cut Plane <br />HIDDEN ELEMENT <br />Hidden Element <br />CUT FILL SYMBOLS COVER FILL SYMBOLS <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />SYMBOL KEY MATERIAL LEGEND <br />Concrete Masonry Unit <br />Nonstructural Brick Masonry <br />Nonstructural Stone Masonry <br />Steel <br />Structural Concrete <br />Nonstructural Concrete <br />Plywood <br />Wood Siding or Paneling <br />Wood Flooring <br />Gypsum Board <br />Carpeting <br />Rigid Insulation <br />Spray Foam Insulation <br />Batt Insulation <br />Earth <br />Glulam <br />Shingles <br />(Material & Exposure May Vary) <br />Wood Siding or Paneling <br />(Spacing & Orientation May Vary) <br />Flagstone <br />Brick <br />(Bond May Vary) <br />Board & Batten <br />Fieldstone <br />Limestone - Stacked <br />Limestone - Stacked <br />Concrete Masonry Unit <br />GENERAL NOTES <br />1. Current International Residential Code (IRC) and Minnesota <br /> State Building Code (MSBC) shall govern. All Subcontractors <br /> and Vendors herein accept their respective responsibility for <br /> compliance. <br />2. Plans are representational only and are subject to field <br /> verification. <br />3. The Work shall include labor and material, not specifically <br /> indicated, which are necessary to complete the job in a manner <br /> which is consistent with Landschute standard practices. It is <br /> understood that the plans and specifications do not necessarily <br /> indicate all Work required for the full performance and <br /> completion of the Work. Inconsistencies in the quality or <br /> quantity of Work indicated shall be interpreted in accordance <br /> with Landschute standard practices and must be addressed <br /> prior to execution of the Work. <br />4. Any request for extra charges shall only be valid if submitted <br /> and agreed to prior to the execution of Work. Commencement <br /> of Work constitutes acceptance of substrate. All work shall be <br /> performed in a neat, craftsman like manner with extra care and <br /> consideration given to protecting work already in place. Each <br /> party is responsible for repairing its own damage to the job and <br /> for removing its own debris to a designated area on the job site. <br /> All tradesmen on the job are responsible for knowing and <br /> adhering to the above-outlined policies. <br />5. If Subcontractor / Vendor fails to correct work or persistently <br /> fails to carry out work as required, Landschute may, by giving <br /> 48 hour notice, terminate the agreement, perform the work itself <br /> and deduct the costs from any balance owed to Subcontractor / <br /> Vendor. If, during the first year of occupancy, it is necessary for <br /> the Subcontractor / Vendor to repair its work as a result of <br /> deficiency in labor or material, it shall also repair any <br /> subsequent trade's work as to create a finished product. <br />6. No payment for any subcontract labor shall be made until <br /> appropriate Certificates of Insurance, including coverage for <br /> both General Liability and Workers' Compensation are provided <br /> to and acknowledged by Landschute. <br />7. Selections for finish materials, fixtures, equipment, and <br /> furnishings to be coordinated directly between Client and <br /> Landschute. <br />N