Laserfiche WebLink
ScaleProject numberDateDrawn byAVA STUDIO4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436PHONE 612 532 8159EMAIL AVASTUDIO.AB1@GMAIL.COM12" = 1'-0"6/28/2023 11:15:41 AMA01Cover Page1380Orono1380 Rest Point Rd5/31/2023Alexander BocharnikovALL PLANS ARE TO BE REVISED BY THE GENERALCONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION.AVA STUDIO LLC. IS NOT RESPONSIBLEFOR ANY PROBLEM AS A RESULT OF AN ERROROMISSION ON THESE PLANS.PLAN INFORMATIONCODE INFORMATIONSheet ListSheetNumberSheet NameA02 ElevationsA03 Foundation / BasementA04 Main LevelA05 Upper LevelA06 Site PlanA07 Rear 3D ProposedA10 Detail Plan 2 of 2E1 BasementE2 Main LevelE3 Upper LevelA11 Bracing NotesA12 Bracing PlanA01 Cover PageArea ScheduleArea LevelName1837 SF Second Floor Upper Level1284 SF Basement Floor Finished Basement1624 SF First Floor Main Level820 SF First Floor Garage176 SF First Floor Porch503 SF First Floor Deck78 SF Basement Floor Stairs100 SF Basement Floor Mech RoomFRAMING NOTES:-ALL EXTERIOR WALLS TO BE 2X6 @ 16" O.C. WITHA DOUBLE TOP PLATE UNLESS OTHERWISENOTED.-WALL FRAMING SHALL BE S.P.F. STUD GRADE ORBETTER UNLESS NOTED OTHERWISE (U.N.O.)-ALL HEADERS SHALL BE (2) -2X10 U.N.O.-EXTERIOR SHEATHING SHALL BE 7/16" MATERIALCONSISTING OF ORIENTED STRAND BOARD (OSB).-ALL FLOOR AND CEILING SYSTEMS TO CHECKEDAND DESIGNED BY THE DESIGNATEDMANUFACTURER. TRUSS PLANS TO BE ON SITE @TIME OF FRAMING-PRESSURE TREATED WOOD IS TO BE USEDWHERE WOOD IS IN CONTACT WITH CONCRETEAND AT 2X8 MUD SILL. TREATED MEMBERS TO BES.Y.P. #2 OR BETTER.-FOR OPENINGS IN EXTERIOR WALLS (OR WALLSWITH LATERAL LOADING:a) 0'-0" -4'-0" = 1 JACK STUD b) 4'-0" -8'-0" = 2 JACK STUDSc) 8'-0" -12'-0" = 3 JACK STUDSd) GREATER THEN 12' = CONSULT ENGINEER.-POSTS CALLED OUT ARE NUMBER OF KINGSTUDS REQUIRED PER SIDE OF OPENING.CONCRETE NOTES:-ALL CONCRETE FOOTINGS AND FOUNDATIONSYSTEMS ARE DESIGNED FOR A 2000 P.S.F. SOIL-FOUNDATION WALLS SHALL BE FULL HEIGHT ATUNBALANCED FILL GREATER THEN 3'-4"-1/2" ANCHOR BOLTS EMBEDDED 7" MINIMUM @ 4'O.C. MAX. 12" MIN. FROM EACH END. MINIMUM OF 2BOLTS IN EACH SILL PLATE-PAD FOOTINGS REINFORCEMENT IS TO BELOCATED 3" FROM BOTTOM OF FOOTING TYP.(WHEN REQUIRED)-CONTRACTOR IS RESPONSIBLE FOR ALL STEELREBAR SIZING PER STATE AND LOCAL BUILDINGCODES-MIN. 5000 PSI CONCRETE @ ALL FOOTINGSINSULATION:-ALL EXTERIOR WALLS TO HAVE A MINIMUM RATING OFR-20-ALL ATTIC SPACES ARE TO HAVE A MINIMUM RATINGOF R-49-ALL FLOOR SPACES OVER UNCONDITIONED SPACEOR CANTILEVERED ARE TO HAVE A MINIMUM RATINGOF R-30SHEETROCK:-ALL CEILINGS ARE TO HAVE 5/8" NON-SAG GYPSUMBOARD U.N.O.-ALL WALLS ARE TO HAVE 1/2" GYPSUM BOARD U.N.O.-GARAGE CEILING AND WALLS THAT ADJOIN HOUSEWALLS ARE TO BE 5/8" TYPE "X" GYPSUM BOARDU.N.O.-ALL EXTERIOR WALLS OF GARAGE AND HOUSE THATARE WITHIN 5' SETBACK TO HAVE 5/8" TYPE "X"EXTERIOR GRADE GYPSUM BOARD ON EXTERIORSIDE OF WALL AND 5/8" TYPE "X" ON INTERNAL SIDEOF WALL.DOORS AND WINDOWS:ALL WINDOWS AND DOORS TO NE DOUBLE GLASS PANELS WITH LOW-E RATINGS.-ANY WINDOW WITHIN 24" OF A DOOR SWING MUST BETEMPERED-ANY WINDOW ABOVE A TUB MUST BE TEMPERED-ANY WINDOW WITHIN A STAIRWAY MUST BE TEMPERED-WINDOW GLAZING MUST BE AT LEAST 18" ABOVEFINISHED FLOOR WHEN WINDOW IS ABOVE 6' FROMGRADE.-ALL BEDROOMS TO HAVE AT LEAST ONE WINDOW THATHAS A CLEAR EGRESS OPENING OF 5.7 SQ. FT. WITH MIN.DIMENSIONS OF 24" IN HEIGHT AND 20" IN WIDTH, SILLHEIGHT NOT TO BE GREATER THEN 44" ABOVE FINISHEDFLOOR.-WINDOWS WITH SILLS WITHIN 3' OF THE FLOOR THEYSERVE AND ARE 72" ABOVE GRADE MUST EITHER HAVE AFALL PREVENTION OR OPENING LIMITER DEVICE PERCODE.MECHANICAL & ELECTRICAL:-ALL ELECTRICAL AND MECHANICAL EQUIPMENT TOBE VERIFIED AND INSTALLED PER CODE BYAPPROVED TRADES AND INSTALLERS.PLAN INFORMATIONCODE INFORMATIONSOIL TYPE:DESIGNED WITH 2000 PSF SOILS, ALL FOUNDATION CONSTRUCTION MUST FACTOR IN THIS AT MINIMUMGENERAL NOTES:-ALL FOUNDATION WALL STRUCTURAL INFORMATIONUSED TO CONSTRUCT THE FOUNDATION SYSTEM ISTO BE ON SITE WHEN POURING OR BUILDING WALLS.-ALL STRUCTURAL BEAMS, POSTS & TALL WALLS ARETO BE BUILT PER I-LEVEL SPECIFICATIONS.-ALL MANUFACTURED FLOORS & ROOF TRUSSES ARETO BE INSTALLED PER MANUFACTURERSSPECIFICATIONS.-ALL MANUFACTURED FLOOR & ROOF TRUSSSPECIFICATIONS ARE TO BE ON SITE DURINGINSTALLATION.WINDOW AND EXTERIOR DOOR U-FACTOR TO BE 0.30 OR BETTERGLASS SOLAR HEAT GAIN COEFFICIENT (SHGC) TO BE 0.28 OR BETTERWINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS SHALL COMPLY WITH THE REQUIREMENTS OF ASTM F 2090CODE INFORMATION:SINGLE FAMILY CONSTRUCTION TYPE V-B-2020 MINNESOTA STATE RESIDENTIAL CODE-2020 NATIONAL ELECTRICAL CODE-2020 MINNESOTA STATE MECHANICAL&FUEL GAS CODE-2020 MINNESOTA STATE FIRE CODE-2020 MINNESOTA PLUMBING CODEWIND EXPOSURE:DESIGNED WITH "EXPOSURE B" CLASSIFICATIONS AND WIND GUSTS OF 115 MPH PER 2020 MN IRC CODE REGULATIONS.12" = 1'-0"13D View 112" = 1'-0"23D View 2Exhibit B Resolution 7400