S-P TESTINGt INC. steven B. Schirmers - MPCA Cert. No. 627 <br />* 05^ Kstydid Lane NE • St. Michael, MN 55376 • (612) 497*3566 <br />November 15# 1995 u <br />Dennis Platteter <br />809 No.Brown Rd. <br />Lot 2, Block 1 <br />Orono, Henn. Co.» MN <br />This On-Site Sewage Treatment System is Designed tor a <br />SSSrooS home Desi|ned in accordance with the Minnesota Pollution <br />Control Agency Chapter 7080 and local ordinances. <br />The soils on this site are a clay loam. The seasonally saturated <br />sSils were located at 20" to 28" (mottled svitemLrface. Due to the saturated soils, a Pressurized Mound System <br />will need to be installed to treat septic effluent. <br />The soils at a depth of 12" have a percolation rate averaging <br />9.8 min/inch. <br />A pumping chamber will need to be installed to lift the effluent <br />to the treatment area. <br />The manifold and supply line pipe must have ^®®!j,^g^their ends*'* pumping chamber. The distribution pipes shall have ^heir ends <br />capped. Be sure the rock and sand fill material are clean. The <br />sod layer below the entire mounded area must be turned ove , 3 <br />break up the sod, be sure not to over work. <br />The power supply and switches must be located outside <br />and pSmping cLiber in a weather proof ^must be installed with a light and sound device, this is in case of <br />a pump failure. (mer <br />All neighboring wells are located greater than 100' away from <br />the proposed treatinent area* <br />Keep all heavy equipment off of the proposed <br />and after construction. The treatment area should be marked oft <br />before construction. This Design is not valid & the system will <br />need to be relocated if failure to protect the areas proposed <br />for On-Site Sewage Treatment occurs. <br />CONT•D
The URL can be used to link to this page
Your browser does not support the video tag.