Laserfiche WebLink
1 <br />Zoning File #1619 <br />February 14, 1991 <br />Page 7 <br />Lob 1 — the dralnfield sites are located on a relatively <br />flat area at the north half of the lot. These sites are <br />about 18* vertically higher than the major wetland to the <br />west, and are located on slopes ranging from 2 to 6%. These <br />sites force the house to be located in the south half of the <br />lot at the edge of the 40% slope leading down to the <br />wetland. The house location further north on the lot would <br />leave minimal setbacks to the mound systems and require that <br />a driveway be constructed along the 40% slope, leaving a <br />major cut just downhill from the primary site. Because of <br />the steep slopes and location of septic systems, this lot is <br />severely limited to a single buildable envelope being <br />approximately 175* in length and ranging in width from 50* <br />to 90*, the Planning Commission and Council allow a 30* <br />setback from the east lot line of Lot 1. <br />Lot 2 - has drainfield sites centrally located just north of <br />the small pond. The primary site ranges in slope from 4% in <br />the south end to near 9% at the very north end. The <br />alternate site just to the west averages 6% slope. These <br />sites are located immediately uphill from the proposed house <br />site. Due to this, and coupled with a drainage swale from <br />the pond being located on the west side of the house, plus <br />the 50* rear setback requirement, this is at best a very <br />poor building site with drainfield sites that are marginal <br />due to site topography. <br />A further issue with Lot 2 is that an extremely long <br />driveway will have to be constructed to reach the proposed <br />house location. If Outlot B is allowed as a private drive­ <br />way, the actual driveway length from the proposed house site <br />on Lot 2 to the point of access on Lyman Avenue is 650*. <br />The State Fire Code will likely require that the driveway be <br />provide with a turnaround, and be not less than 20* <br />unobstructed width, hence this will make a shared driveway <br />on Outlot. B just that much tougher to construct. <br />Lot 3 - contains the existing house which has an existing <br />failing septic system. Both the primary and alternate <br />drainfield sites have been tested on this property. The <br />primary site has a slope of approximately 2%, the alternate <br />site has a slope of about 6%. With approximately 40* <br />between the easterly tip of the primary mound and the east <br />lot line, it might be feasible to relocate the driveway <br />within Lot 3 to a point where it could access Lyman Avenue <br />within the boundaries of the plat, eliminating the need for <br />a driveway easement on the neighboring property. However, <br />the sight distance for Outlot B's access point to Lyman <br />Avenue is already minimal if not unacceptable, hence an <br />additional access at that location may not be a wise <br />decision.