KOCH’S SOIL TESTING <br />P.O.BOX 81 <br />LORETTO.MN 55357 <br />TEL: (612) 479-2637 <br />Edna Albce Estate 1/2/96 <br />Job Site: 1575 Long Lake Blvd., Orono, Mn. <br />Percolation tests and soil borings were done on the above lot on 11/7/95 to determine <br />what type of drainfield could be installed to replace the current system which is not a <br />xTe'^^^raBVperedation rate was 19.9 min/m. and the depth to mottled soil was at 39-48 <br />inches.* See the enclosed soil borings and percolation tests for the details. Note: the perc, test <br />and soil borings were done on 11/7/95. , . , • <br />Initially a pressurized system was designed for this properly due to the mottled soil level <br />of39 inches in Soil Boring#!. <br />Upon further soil boring investigation on 12/27/95 with Mr. Jim Anderson (University of <br />Minnesota), Mike Gaffron and Steve Weekman (City of Orono), Duane Ritter (Du^e <br />Ritter Excavating, Rockford, Mn.) and Robert Koch (Koch Soil Testing, Loretto, 1^.) <br />present it was the general consensus that a 10 inch gravelless trench system could be <br />installed. Three soil borings were taken that day (12/27/95) and mottled was oun a <br />42 inches to 48 inches. It was agreed that the gravelless trench system would be the <br />oreferred system for this lot. . „ <br />The depth of the gravelless on the downhill side should be at least 6 inches into cxistmg <br />soil The soil located in between the trenches should be scarified up with the teeth of the <br />backlioe and similar topsoil (black loam) be added into this area to ensure a minimum <br />cover depth of 6 inches over entire drainfield area. The decision on when the placemen <br />of topsoil will be done will be up to the contractor/installer as proper drainage areas wi <br />have to be developed at the same time. <br />The amount of 10 inch gravelless pipe needed for a 3 bedroom home b^ed on 450 <br />gal./day water usage with a perc. rate of 19.9 min./inch would be of the following size: <br />Overall size: 750 sq.ft. Total amount of pipe needed: 250 ft. t-. r ^ <br />However, it was felt that only 80% of the pipe would be filled with effluent. Therefore, <br />the system should be increased by 20% or to a size of 900 sq. ft. <br />Overall drainfield size: 900 sq. ft. <br />Total amount of 10 inch gravelless pipe needed; 300 ft. , « nr r,mn <br />This would amount to using 5 trenches. (1-50 ft., 1-95 ft., 1-80 ft., 1-70 ., - ) P <br />boxes should be used to distribute effluent to the trenches. <br />Two 1,000 gallon sealed septic tanks should be used. These tanks should be pumpe ou <br />every 2-3 years. This practice will enhance the life of tiie system. <br />Robert Koch <br />MPCA Certified