Laserfiche WebLink
Item 19 - Tanker Midwest 2000 gallon 4.3.23, Spec, 3313S <br />Save Date: 8/25/2023 8:48 AM Customer Initials ______ <br />Print Date: 8/25/2023 8:48 AM 22 Rev P <br />13.06.01.01 One (1) intake, street side <br />13.06.02 Non-Gated Master Intakes <br />Master intakes are plumbed out both sides of the pump house and capped with a chrome long <br />handled cap. <br />13.06.02.03 Two (2) 6” intakes <br />13.07 Discharges <br />Discharges include: <br />• Tee Handle Control <br />• 2 ½” 400 PSI Liquid Filled Stainless Pressure Gauge <br />• 30 Degree Elbow, cap and chain <br /> <br />13.07.01 Side Control Pump Panel Discharges <br />13.07.01.02 Two (2) 2 ½” Discharge, Street Side <br />13.07.01.03 One (1) 2 ½” Discharge, Curb Side <br />13.08.08 Plumbing for Deck Gun <br />13.08.08.01 Deck Gun Port <br />Port left accessible for future install of deck gun plumbing. A gauge, valve, and handle are not <br />provided. <br />13.09 Tank Fill/ Tank to Pump <br />13.09.01 Tank Fill Valve 2” <br />A 2" tank fill/pump re-circulating line provided from the pump to the water tank, with a 2" <br />valve and 2" high-pressure flexible hose. <br />13.09.01.01 2” Tank Fill Valve, Side Control <br />13.09.03 Tank to Pump 3” <br />A 3” tank to pump line provided from the water tank to the pump, with a 3” valve and tee <br />handle controls, and 4” plumbing with flexible connection with check valve. <br />13.09.03.01 Manual Controls, Side Control <br />13.11 Pump House Heat Control <br />13.11.07 Pump Compartment Seal <br />A rubber seal provided between the rear of the pumphouse and the body. <br />13.12 Pump Certification <br />13.12.01 MWF Calibration <br />The pump test shall be certified by a Midwest Fire representative.