Laserfiche WebLink
PROJECT SCOPE FRAMING NOTES <br />DESIGN OF ISOLATED PAD AND PIER FOOTINGS, BEAM AND HEADER FRAMING. TALL WALLS I . ALL HEADERS ARE TO BE MINIMUM (2) 2x10 LUMBER UNLESS NOTED OTHERWISE. <br />GREATER THAN 12 FEET, LOW GRADE FROST FOUNDATION 'WALLS. FRONT WINDOW WELL 2- (2) 2x10 MEMBERS SHOWN MAY BE SUBSTITUTED WITH (2) 13/V x 71/4" LVL OR (3) 13A" x 5112' LVL AS <br />FOUNDATION. STAIRWAY FOUNDATION. AND THE MAIN WINDFORCE RESISTING SYSTEM FOR REQUIRED. <br />A SINGLE FAMILY RESIDENCE. CONSTRUCTION IS TO BE DONE IN ACCORDANCE WITH THESE 3, ALL DIMENSION LUMBER HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE BEARING STUD AT <br />DRAWINGS. STANDARD INDUSTRY PRACTICE. AND THE REQUIREMENTS OF THE CODE. EACH END AND TWO AT INTERMEDIATE SUPPORTS. ALL LVL AND GIRDER TRUSS BEAMS AND <br />GENERAL NOTES HEADERS ARE TO HAVE A MINIMUM OF TWO BEARING STUDS AT EACH END. 3 -PLY MEMBERS ARE TO <br />1. THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS PREPARED HAVE A MINIMUM OF THREE BEARING STUDS AT EACH END UNLESS NOTED OTHERWISE- ADDITIONAL CONSTRUCT RIGID <br />BY DFP PLANNING & DESIGN LAST DATED 11-10-22 FOR MORE INFORMATION. BEARING STUDS ARE NOT REQUIRED FOR LVL SUBSTITUTED FOR STANDARD SAWN LUMBER. ALL SHEAR PANEL AS �, <br />2. IT IS THE RESPONSIBILITY OF THE BU LDER TO PROVIDE ALL FUTURE PLAN CHANGES TO BEARING ABOVE IS UNLESS NOTED OTHERWISE ON PLANS. TRUSS SUPPLIER IS TO VERIFY GIRDER SHOWN IN 1:55 CONSTRUCT RIGID <br />THE HANSON GROUP FOR REVIEW. IF FINAL TRUSS LAYOUTS VARY FROM THOSE TRUSS BEARING LENGTH AND SUPPORT REQUIREMENTS. SHEAR PANEL AS <br />SHOWN ON HOUSE PLANS, NOTIFY ENGINEER PRIOR TO CONSTRUCTION. 4. ALL HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE FULL HEIGHT KING STUD AT EACH END. 6x6 POST w' HELICAL ANCHOR @ 5Y4' x 133/x" GLULAM HEADEREXTENDEb 2 9%•" LVL SHOWN IN 2155 <br />3. ADEOUATE SHORING DURING CONST RUCTION IS THE RESPONSIBILITY OF THE EXTERIOR OPE NINGS GREATER THAN SIX FEET IN WIDTH ARE TO HAVE A MINI MUM OF TWO FULL LANDINGS & DECK CONNECTION TO <br />CDNTRACTOR. HEIGHT KING STUDS AT EACH END, EXCEPT AT TALL WALLS AS NOTED EXTERIOR OPENINGS POST DESIGNED BY SUPPLIER FOR 11 >EXTENDED 2 9Y2' _VL REFER TO 5.'54 FOR <br />4, CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE GREATER THAN TWELVE FEET IN WIDTH ARE TO HAVE A MINIMUM OF THREE FULL HEIGHT KING 5.000 LBS- VERTICAL WORKING LOADS rr rMW <br />wear.. U XREQUIREMENTS w' A <br />PROCEEDING WITH WORK. NOTIFY THE HANSON GROUP IF DISCREPANCIES ARISE- STUDS AT EACH END, EXCEPT AT TALL WALLS AS NOTED- FOR CONTINUOUS BEAM CONDITIONS, TYP. (SEE FOUNDATION NOTE 7) a Gia i <br />5. MEANS AND METHCDS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE SPAN IN DETERMINING NUMBER OF KING STUDS IS THE FULL LENGTH OF THE HEADER. cv I BRACED WALL PANEL <br />CONTRACTOR. 5. ALL CONNECTIONS ARE TO BE MADE WITH ADEQUATE SIMPSON- USP OR EQUAL JOIST HANGERS. 2x12 LEDGER w x iv r , SIMPSON ! / ABOVE A CANTILEVER TYP. <br />(3) LEDGERLOKS� N Cr a HUCQ410 SDS <br />FOUNDATION NOTES CLIPS. POST CAPS. AND POST BASES. CONNECT MULTIPLE MEMBER LVL'S TOGETHER IN INDICATES MIN. (2) 2x6 w '� ! I V <br />@ 19.2' O.C- MA.X. a N a Q FACE MOUNT I I 3 w <br />1. D7AIN TILE, DAMPPROOFING AND OR WATERPROOFING, &INSULATION. AS WELL AS ACCORDANCE WITH MANUFACTURER REQUIREMENTS- BEARING STUDS BELOW CE K a M `' :� " y O ❑ <br />THEIR INSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE. 6. ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, TYP. @DECK HANGER OR <br />CONTINUOUS HEADER ~ N --- � �T Q <br />2. INSTALL A MINIMUM OF 2 ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN U.N.O. (2}2x12 F5 EQUIVALENT ! I a Cr <br />{ } BETWEEN OPENINGS FLUSH OR PARTIALLY y <br />ANCHOR WITHIN 12" OF EACH END AS APPLICABLE. A. 2x6 STUDS SPACED @ 16" Q.C. TYP. U.N-Q. 3,75 -FT `r-. (3)2x10 r---� F2 <br />r FLUSH (3)18" LVL <br />3. BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BAR DIAMETERS. INCLUDING ALL B. WALL SHEATHING: %6" MIN STRUCTURAL PANEL SHEATHING w:' 8d COMMON NAILS @ 6" O.0 AT ) } y ` I 12 I (3)14" LVL - 1 <br />WALL CORNERS & INTERSECTIONS. PANEL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS OR 13/d" 16 GAUGE STAPLES @ 3' ' fi" (7 FT}L__� I J r ; 1 F2 I <br />4. CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT. SPACING.in -- <br />F3 5�- x �'13),1 .," LVL rlt-1 _ <br />RETAINING WALL FOUNDATIONS RELY ON SLAB ON GRADE FOR LATERAL RESISTANCE. 7. ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, TRUSS SUPPLIER TO PSL POST I I I <br />ADEQUATE TEMPORARY BRACING IS BY OTHERS UNTIL SLAB IS IN PLACE AND FULLY U -N -O- ACCOUNT FOR ONE SIDED INTERIOR- L ' L� i I jl I <br />CURED. A. 2x4 OR 2x6 STUDS SPACED @ 16" O -C. STONE AND HEARTH OSB PLYWOOD 5y4' x 5Y�' F4 <br />5. ADEQUATE SHORING IS THE RESPONSIBILITY OF THE CONTRACTOR. B. WALL SHEATHING: Y2' MIN. GYPSUM SHEATHING FASTENED TO FRAMING w+ 5d COOLER NAILS @ ABOVE-TYP. BRACED WALL PSL POST <br />6- TOP OF FOUNDATION WALLS WITH LOW GRADE ARE TO BE LATERALLY SUPPORTED 8" O.C. MAX- OR TYPE S.W WALLBOARD SCREWS @ 16" O.C- MAX. (%g' MINIMUM STUD PANEL PER FRAMING <br />PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. PENETRATION) F1 + NOTE 6 1 <br />7. HELICAL SCREW ANCHORS ARE TO BE DESIGNED BY THE MANUFACTURER FOR A 3- ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA. _ (3)2x1 ¢,__l -BRG BEAM 4' ON <br />WORKING LOAD AS NOTED ON PLAN. INSTALL ANCHORS TO TWICE THIS VALUE FOR AN A. FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C-A L� INDICATES SPAN TREATED POCKET <br />U_TIMATE LOAD RESPECTIVELY WITH A FACTOR OF SAFETY=2. DEPTH OF INSTALLATION B. FLOOR SHEATHING: %" STRUCTURAL FANEL SHEATHING w• 8d COMMON NAILS @ 6" O -C AT PANEL DIRECTION OF - • <br />TO BE DETERMINED BY THE INSTALLER AND!OR A. GEOTECHNICAL ENGINEER. INCREASE EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS. B 2x6 TRUSSES BY <br />LOAD FOR POTENTIAL DOWN DRAG AS REQUIRED. HELICAL ANCHOR RESISTANCE TO �. ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA. 6x6 POST BEARING SUPPLIER TYP. I <br />FROST MOVEMENT IS BY THE MANUFACTURER. A. ROOF FRAMING SPACED AT A MAXIMUM OF 24"0,C. STUDS <br />I <br />MATERIALS B. FASTEN ALL ROOF FRAMING TO TOP PLATES WITH USP RT7 OR SIMPSON H2-5 CLIPS OR F4 F2 =. <br />CONCRETE FOOTINGS: F'C = 5,000 PSI @ 28 DAYS {OR 3,500 PSI WITH AN EQUIVALENT AND (4) 0.131"0 x 3" TOENAILS. „ r {3}22" LVL OR W1Dx5a r , r--1 + �r�r,,,,t_. I ,.•m,,,,,v4 <br />1 I 3 18" LVL zwlw-W . ■W .� . <br />APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR C. ROOF SHEATHING: %" STRUCTURAL PANEL SHEATHING w.+ 8d COMMON NAI_S @ 6" 0.0 AT PANEL I 01R' <br />R f Ox3O L J y j =ALO"` "` - - - - - rt` f e"Q1M`{' - % <br />RESISTANCE AT LEAST EQUIVALENT TO 5.000 PSI CONCRETE) EDGES AND 12" O.C- AT INTERMEDIATE SUPPORTS OR 13/+" 16 GAUGE STAPLES @ 3"' 6" SPACING. �"-�F3 ! "---J <br />DASH -DOT LINES I I <br />CONCRETE WALLS: Fc = 3,500 PSI @ 28 DAYS 10. ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH �- I fix6 POST N - -- - r- r.arno i I <br />INDICATE PRIMARY <br />REINFORCING STEEL: ASTM A61 GRADE 60 (12) 0.131"0 x 3" IN LAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) � I � I y.,r r ��►ca rn° I <br />GIRDER TRUSSES F2 <br />AGGREGATE: FOOTINGS 14" MAX 0.131"Ox 3" FACE NAILS. STAIRS & F1 (4) 2x5 I <br />BY SU PPL ER TYP. <br />WALLS/SLABS- 3/' MAX 11. ALL BEARING POINT OR POST LOADS ARE TO BE BLOCKED SOLID TO THE FOUNDATION. AT A r" ' LVL , LANDINGS -� BEARING <br />(2)9 /2 <br />t I I I i �. „�, <br />ON-SITE SOIL: SAND CLAY {GROUP II) ASSUMED OVERHANGING PLATES. PROVIDE 2x8 SQUASH BLOCKING BELOW BEARING LOADS. '� L J BY SUPPLIEF&---J STUDS <br />IF CLAY SOILS ARE ENCOUNTERED, 12, STEEL BEAM TO BEAM SHEAR CLIP CONNECTIONS (R = 20 KIPS UNLESS NOTED OTHERWISE) ARE BY �y {2}2x70 �'r <br />BACKFILL w: SAND FULL HEIGHT. THE MANUFACTURER. (2)2x1411 <br />f.a = 45 PSF/FT (ACTIVE) 13. STEEL BEAMS ARE TO HAVE SOLID 2 x MINIMUM TOP PLATE FASTENED WITH ' a" DIAMETER BOLTS '0 +r _ <br />BACKFILL SOIL: SAND ;GROUP I TO BE USED WHERE NOTED- STAGGERED EACH SIDE OF WEB AT 48" ON CENTER MAX. WIDTH TO MATCH BEAM. INCREASE PLATE ` J- - -I I" RMW L STORAM <br />fe = 30 PSF;'FT (ACTIVE) THICKNESS AS REQUIRED FOR TOP FLANGE HANGERS. BEAM TOP FLANGE PLATE TO BE BRACED <br />LATERALLY BY FLOOR SYSTEM AT 48" O C. MAX AND AT ENDS TYP. FOR FLUSH FLOOR FRAMING RETURN TOP OF <br />ALLOWABLE SOIL 20" < 8" MIN. CONGRETE <br />CONNECTIONS, BLOCK WEB SPACE SOLID w' LUMBER TIGHT BETWEEN FLANGES AND BOLT THRCUGH WALL BARS 24" MIN <br />BEARING PRESSURE: 2.000 PSF - ASSUMED STRIP FOOTINGS TYP. INTO RETURN <br />WALL STUDS 110' OR LESS}: SPF STUD GRADE OR BETTER WEB w•'Yz"O BOLTS AT 2d" O,C. STAGGERED UNDER ALL FOUNDATION 4 r r„ON,a, <br />i tea':.ar. "rn <br />14. CUT POSTS TO FIT. DO NOT BLOCK WITH WOOD PLATE MATERIAL, CRUSHING WOULD OCCLR. FASTEN WALLS AS SHOWN f °Fcsx�p1°° I I <br />WALL STUDS (OVER 10'): SPF NO.2 GRADE OR BETTER WALLS, INTERIOR BEARING & II�fY <br />STEEL BEAMS TO POSTS w' (4) V,�" x 6" STRUCTURAL WOOD SCREWS- STAIR WALLS AT BOTTOM. TO BEAR DIRECTLY ST"a <br />LSL SUDS: 1Y2" WIDTH - 1.3E OR BETTER <br />DIMENSIONAL LUMBER: SPF NO.2 GRADE OR BETTER ON CONCRETE. IF UNTREATED, WRAP BOTTOM w.' MEMBRANE. i <br />TREATED LUMBER: SYP NO.1 GRADE OR BETTER OR LSL 15. VERIFY DROPPED VERSUS FLUSH BEAM CONDITIONS WITH HOUSE PLANS. � 4 f r <br />16. ALL OTHER FASTENERS TO BE IN ACCORDANCE CODE TABLE R602.3(1). n•a.r.nurs• , r � rl+ W'•wc� j <br />LSL BEAMS: 13/a" WIDTH 1.55E OR BETTER 17. ALL STUD PLIES IN BUILT JP BEARING STUD COLUMNS TO BE FASTENED TO SHEATHING AS SPECIFIED ..� OW <br />17. <br />LVL: 1X- WIDTH -1.9E OR BETTER "°' M40IeK1O.,�e �"` ~0Y` <br />IN NOTES 6 AND 7. Nn me <br />PSL: 1.8E DR BETTER A.a..�M .. r.�� <br />TREATED GLULAM: SYP 26FV4 18- THE DECK AND FRONT ENTRY PORCH ARE CONSIDERED PRIMARILY OPEN, NON-ESSENTIAL PORTIONS `r + H�^ <br />WESTERN CEDAR TIMBERS: SELECT STRUCTURAL Fb=1,150 PSI, 1.0E OR BETTER OF THE STRUCTURE AND ARE EXCLUDED FROM THE MAIN WINDFORCE RESISTING SYSTEM OF THE PROVIDE ADDITIONAL TOP <br />STRUCTURAL STEEL: ANGLES. MISC - ASTM A35 (Fy = 36KSI) HOME. PROVIDE CODE REQUIRED UPLIFT CONNECTION AT ALL POSTS AND TENSION CONNECTIONS CL " J <br />�OF WALL REINFORCEMENT <br />AT LEDGERS. w AS SHOWN BELOW I ,- <br />TUBES - ASTM A500 Gr. B (Fy =46 KSI) 19- TALL WALL FRAMING IS DESIGNED TO A H/180 DEFLECTION CRITERIA (H.'240 @ STONE) AT A MINIMUM- � z 3 <br />W SECTIONS - ASTM A992 (Fy = 50 KSI) _ 3: <br />(MIN. LENGTH) <br />INDICATES EXTERIOR BRACED WALL PANEL w: SHEATHING ON EXTERIOR FACE IN ACCORDANCE w FRAMING NOTE 6- <br />_ <br />PROVIDE INCREASED FASTEN NG REQUIREMENTS AS SHOWN BELOW. <br />(MIN. LENGTH} - INDICATES INTERIOR BRACED WALL PANEL w GYPSUM SHEATHING BOTH FACES WITH EITHER FASTENER OPTION LISTED IN <br />FRAMING NOTE 7. SPACED AT 4' O.C. PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW. <br />- INDICATES ENGINEERED WIND RESISTING ELEMENTS TO BE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS. <br />REPRESENTSROOF TRUSSES RDOFTRU55 <br />U <br />FIGURE FASTENED TO PLATES FASTENED TO <br />FLAT 2x6 @ 24" O -C. <br />R602.10 -8-"e(3) wl (4) 0.131'0 x 3" PLATES <br />PLATO <br />(MIN. (3) PER BRACED <br />TOENAILS & SIMPSON x 3" <br />WALL PANEL) <br />FRAME 2x4 BOX H2.5 CLIP TOENAILS <br />AROUND SPACE <br />ROOF <br />2x4 BLOCKING @ 6. O.C. <br />BETWEEN TRUSS w' BETWEEN <br />1� TRUSSES <br />SAME SHEATHING TRUSSES NAILED <br />F4 <br />AND FASTENING AS TO TOP PLATES NAIL BOTTOM <br />WALL BELOW <br />#5 BARS @ 12" O.C. <br />wl (3) 0.131 "O x 3" PLATE TO LADDER <br />4'-4" x 4'-O" x 12" <br />;OR REPLACE w+ NAILS EACH TRUSS w..'(3) 16d <br />ADEQUATE DEPTH NAILS EVERY 16" <br />(4] 0.131 "O� Sim <br />x 3" NAILS A35 <br />2x MEMBER] NAIL BOTTOM PLATE <br />BRACED FRAMING <br />#12 x 3Y2' WOOD J TO RIBBON BRACE ' <br />WALL PANEL ANGLE <br />SCREWS @ 16"0.C- w TRUSSES TRUSS w.' (3) 16d w TRUSSES <br />EACH END <br />INSTALLED IN NAILS EVERY 16"NAIL LADCER <br />ADDITION TO NAILS TRUSS TO TOP <br />BRACED WALL CONNECTION <br />(ROOF TRUSSES) <br />UPPER PLATES wi <br />(MAIN NAIL EACH TRUSS TO <br />LEVEL ROOF 0.131"0 x 3" <br />TOP PLATES (3) NAILS @ 6" O.C. <br />TRUSS BEARING p -131"D x 3" TOO ENAILS <br />FLOOR <br />WALLS ONLY) <br />TRUSS <br />EXTERIOR BEARING WALL EXTERIOR NON-BEARING WALL <br />(4)0 <br />2x4 BLOCKING BETWEEN PROVIDE ROOF TPU55 <br />ROOF TRUSSES NAILED DIRECTLY IN LINE w/ <br />'NAI <br />x 3" NAILS <br />/ TO TOP PLATES wl (3) I BRACED WALL PANEL <br />BRACED51MP50N <br />0.131"0 x 3" NAILS EACH FASTENED TO PLATES <br />WALL PANEL <br />LTP4 <br />W/ 0.131 "0 x 3" <br />FLAT 2x6 @ 24' O C- FRAMING <br />TOENAILS @ 6' 0.C- <br />(MIN. (3) PER BRACED PLATE <br />WALL PANEL) EACH END <br />NAIL BOTTOM PLATE TO <br />BLOCKING w (3) 16d <br />FLAT 2x6 @ 24" O C'SIMPSON <br />NAILS EVERY 16" -NAIL BOTTOM PLATEDa <br />TO BLOCKING W (3) <br />(MIN(3) PER BRACED LTP4 <br />. <br />WALL PANEL] FRAMING <br />PLATE <br />PROVIDE FULL DEPTH 16d NAILS EVERY 16" <br />BRACED EACH END <br />BLOCKING BETWEEN TRUSSES <br />WALL PANEL <br />w TRUSSES NAILED TO TOP PLATES w' w TA05SE5 <br />(3) 0.131'0 x 3' NAILS EACHTPROVIDE TRUSS DIRECTLY <br />(4) 0.131"0- <br />IN LINE w BRACED WALL <br />x 3' NAILS <br />NAIL EACH TRUSS TO TOP PLATE PANEL FASTENED TO <br />w. I3) 0.131 "0 x 3" TOENAILS PLATES w 0-131"O x 3" <br />TOENAILS @ 6" O.G- <br />FLOOR <br />TRUSSES <br />INTERIOR WALL INTERIOR WALL <br />PERPENDICULAR TO FRAMING PARALLEL w' FRAMING <br />BRACED WALL CONNECTION <br />(FLOOR TRUSSES; <br />SECTIONS SHOWN DEPICT CONNECTIONS CF BRACED WALL PANELS TO ROOF TRUSSES <br />DETAILS SHOWN ABOVE ARE <br />ABOVE. TO TRUSSES BLOCKING ABOVE. AND TO TRUSSESBLOCKING BELOW- THESE PANELS <br />ALTERNATIVE CONNECTIONS TO BE <br />ARE NOT NECESSARILY REOUIREO TO ALIGN. BUT MAY DEPENDING ON PLAN LAYOUT. <br />USED WHEN BRACED WALL PANEL <br />DOES NOT ALIGN WITH FRAMING. <br />THESE SHEETS REPRESENT A COMPLETE DESIGN OF THE 'MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRE RESIDENTIAL STRUCTURE. <br />THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WIND RESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON <br />GROUP'S DESIGN IS SHOWN ON THE STRUCTURAL DRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING. <br />@ COPYRIGHT HANSON GROUP, LLC 2022 <br />LOADS <br />ROOF LIVE LOAD: 35 PSF (SNOW) <br />ROOF DEAD LOAD. 15 PSF <br />FLOOR LIVE LOAD: 40 PSF <br />FLOOR DEAD LOAD: 15 PSF <br />WIND LOAD: 115 MPH ULTIMATE EXP. B <br />CODE <br />2020 MINNESOTA RESIDENTIAL CODE <br />ABBREVIATIONS <br />TYP. _ TYPICAL <br />SIM. = SIMILAR <br />U.N.Q. UNLESS NOTED OTHERWISE <br />MIN. MINIMUM <br />MAX. - MAXIMUM <br />O.C. = ON CENTER <br />0-14 - CONTINUOUS OVER <br />SLOPE GRADE AWAY <br />FROM FOUNDATION <br />-1 II=I I F <br />#4 VERT. BARS @ 24- -1 <br />4.C.� <br />PROVIDE 2" RIGID <br />INSULATION AT BASE <br />OF WELL & UP SIDE <br />& REAR WALLS <br />BELOW GRADE <br />#4 x 2•-0" DOWELS @ 24" O.0 <br />(5" MIN. EMBED) CENTERED IN WALL <br />20'x 8' MIN. CONCRETE <br />STRIP FOOTING UNDER <br />WINDOW WELL WALLS <br />a � <br />2 WALL SECTION <br />53 WINDOW WELL SIDE WALL <br />(3) #4 HORIZ. BARS PLACED <br />TIGHT AGAINST VERT. BARS <br />JUST BELOW LEDGE <br />TYP. VERT. BARS <br />PER S 1 -S2 <br />DE <br />10" MIN. C.I.P. <br />CONCRETE WALL <br />REFERENCE PLAN <br />53 LOWER LEVEL PLAN SHOWN FOR <br />LOCATION REFERENCE ONLY <br />PLAN NOTES: <br />• ALL REMAINING BEAMS AND HEADERS NOT SPECIFIED ARE TO BE MIN. <br />(2) 2x10 OR AN ALLOWABLE SUBSTITUTE LISTED IN THE FRAMING NOTES. <br />■ PROVIDE (2) 2x6 BEARING STUDS AT ENDS OF ALL GIRDER TRUSSES U-N.O- <br />• SEE FRAMING NOTES FOR BEAM AND HEADER SUPPORT REQUIREMENTS. <br />DESIGN SHOWN FOR 3 S3 RELIES ON CURED CONCRETE SLAB FOR <br />TOP OF WALL LATERAL SUPPORT. MEANS AND METHODS OF <br />BRACING DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE <br />CONTRACTOR. THE HANSON GROUP RECOMMENDS EITHER STEEL <br />BRACING ALONG THE EXTERIOR PERIMETER OR POURED CONCRETE <br />WING WALLS ALONG THE INTERIOR PERIMETER BY OTHERS. <br />SLAB -ON -GRADE - , 2" LEDGE <br />PROVIDE GRANULAR MATERIAL <br />FOR FILL BELOW SLAB s <br />#4 x 5'-0" HOOKS <br />@ 24" 0. C. <br />#z HORIZ. BARS @ 24" O.C. <br />MAX. ABOVE GRADE <br />#4 x 2'-0" DOWELS @ 72" O.C. <br />(5" MIN. EMBED) CENTERED IN WALL <br />20' WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />(PROVIDE ADEQUATE <br />FROST PROTECTION) <br />C <br />ra••a' � ^. ' <br />20'x 8" MIN. CONCRETE <br />STRIP FOOTINGS TYP. <br />UNDER ALL FOUNDATION <br />WALLS @ GARAGE <br />� I <br />L <br />t rrrrrw.- <br />*eWrro.: <br />low COC F • <br />Sdk.ft. 9T1lA. <br />hiemm gra <br />0 o.n was <br />ueor oae 4x w <br />ra•+r "K rye <br />i <br />i <br />r or r .awev � <br />.r os r'arev I <br />er,r wr rr. i I <br />• m <br />Nropaucv -- -- - ----- I <br />care n0 t } <br />. r -O I ",-e + rr-e <br />8" MIN. G.I.P. O & <br />CONCRETE WALL F o <br />Ow <br />2 x <br />w <br />III-7SLOPEGRADEAWAY <br />FROM FOUNDATION <br />z <br />B" OR 10" C.I.P. 5 <br />CONCRETE WALL o <br />v <br />3 WALL SECTION <br />S3 LOW GRADE FROST <br />FOUNDATION WALL <br />r <br />D.F.P. Planning & Design <br />9100 Baltimore St NE, Suite 106 <br />Blaine, MN 55449 <br />Revision Date Description <br />PLANS SHCWN LIGHT IN BACKGROUND ARE FOR <br />LOCATION REFERENCE ONLY. PLAN NOTES AND <br />ELEMENTS SHOWN LIGHT MAY NOT NECESSARILY <br />SUPPORT THE HANSON GROUP'S DESIGN. <br />CONCRETE PAD FOOTING SCHEDULE <br />�­ 8" MIN C.I.P. <br />FOOTING SIZE <br />CONCRETE WALL <br />e <br />2" TO HORIZ. BARS <br />164 <br />NONE <br />F2 <br />2'-6' x 2'-6' x 8" <br />#4 HORIZ BARS 5C <br />a <br />F2 -ALTERNATE <br />@ 24" G.C. <br />NONE <br />C? <br />3-0" x T-0" x 12" <br />as <br />F4 <br />GRANULAR <br />#5 BARS @ 12" O.C. <br />-1, MATERIAL "? <br />4'-4" x 4'-O" x 12" <br />( SAND) <br />7/7-7/7777777773 <br />20'x 8' MIN. CONCRETE <br />STRIP FOOTING UNDER <br />WINDOW WELL WALLS <br />a � <br />2 WALL SECTION <br />53 WINDOW WELL SIDE WALL <br />(3) #4 HORIZ. BARS PLACED <br />TIGHT AGAINST VERT. BARS <br />JUST BELOW LEDGE <br />TYP. VERT. BARS <br />PER S 1 -S2 <br />DE <br />10" MIN. C.I.P. <br />CONCRETE WALL <br />REFERENCE PLAN <br />53 LOWER LEVEL PLAN SHOWN FOR <br />LOCATION REFERENCE ONLY <br />PLAN NOTES: <br />• ALL REMAINING BEAMS AND HEADERS NOT SPECIFIED ARE TO BE MIN. <br />(2) 2x10 OR AN ALLOWABLE SUBSTITUTE LISTED IN THE FRAMING NOTES. <br />■ PROVIDE (2) 2x6 BEARING STUDS AT ENDS OF ALL GIRDER TRUSSES U-N.O- <br />• SEE FRAMING NOTES FOR BEAM AND HEADER SUPPORT REQUIREMENTS. <br />DESIGN SHOWN FOR 3 S3 RELIES ON CURED CONCRETE SLAB FOR <br />TOP OF WALL LATERAL SUPPORT. MEANS AND METHODS OF <br />BRACING DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE <br />CONTRACTOR. THE HANSON GROUP RECOMMENDS EITHER STEEL <br />BRACING ALONG THE EXTERIOR PERIMETER OR POURED CONCRETE <br />WING WALLS ALONG THE INTERIOR PERIMETER BY OTHERS. <br />SLAB -ON -GRADE - , 2" LEDGE <br />PROVIDE GRANULAR MATERIAL <br />FOR FILL BELOW SLAB s <br />#4 x 5'-0" HOOKS <br />@ 24" 0. C. <br />#z HORIZ. BARS @ 24" O.C. <br />MAX. ABOVE GRADE <br />#4 x 2'-0" DOWELS @ 72" O.C. <br />(5" MIN. EMBED) CENTERED IN WALL <br />20' WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />(PROVIDE ADEQUATE <br />FROST PROTECTION) <br />C <br />ra••a' � ^. ' <br />20'x 8" MIN. CONCRETE <br />STRIP FOOTINGS TYP. <br />UNDER ALL FOUNDATION <br />WALLS @ GARAGE <br />� I <br />L <br />t rrrrrw.- <br />*eWrro.: <br />low COC F • <br />Sdk.ft. 9T1lA. <br />hiemm gra <br />0 o.n was <br />ueor oae 4x w <br />ra•+r "K rye <br />i <br />i <br />r or r .awev � <br />.r os r'arev I <br />er,r wr rr. i I <br />• m <br />Nropaucv -- -- - ----- I <br />care n0 t } <br />. r -O I ",-e + rr-e <br />8" MIN. G.I.P. O & <br />CONCRETE WALL F o <br />Ow <br />2 x <br />w <br />III-7SLOPEGRADEAWAY <br />FROM FOUNDATION <br />z <br />B" OR 10" C.I.P. 5 <br />CONCRETE WALL o <br />v <br />3 WALL SECTION <br />S3 LOW GRADE FROST <br />FOUNDATION WALL <br />r <br />D.F.P. Planning & Design <br />9100 Baltimore St NE, Suite 106 <br />Blaine, MN 55449 <br />Revision Date Description <br />PLANS SHCWN LIGHT IN BACKGROUND ARE FOR <br />LOCATION REFERENCE ONLY. PLAN NOTES AND <br />ELEMENTS SHOWN LIGHT MAY NOT NECESSARILY <br />SUPPORT THE HANSON GROUP'S DESIGN. <br />CONCRETE PAD FOOTING SCHEDULE <br />MARK <br />FOOTING SIZE <br />REINFORCEMENT EACH WAY <br />F1 <br />2'-0" x 2'-0' x 8" <br />NONE <br />F2 <br />2'-6' x 2'-6' x 8" <br />#5 BARS @ 12" O.C. <br />F2 -ALTERNATE <br />2'-6" x 2'-6" x 12" <br />NONE <br />F3 <br />3-0" x T-0" x 12" <br />#5 BARS @ 12" O.C. <br />F4 <br />3-6" x 3'-6" x 12" <br />#5 BARS @ 12" O.C. <br />F5 <br />4'-4" x 4'-O" x 12" <br />#5 BARS @ 12" O.C. <br />LOCATE REINFORCEMENT 3" FROM THE BOTTOM OF FOOTING <br />BUILDER IS REQUIRED TO SEND FINAL TRUSS <br />LAYOUT DRAWINGS TO THE HANSON GROUP <br />PRIOR TO CONSTRUCTION FOR VERIFICATION OF <br />LOAD PATHS AND FRAMING SIZES LISTED <br />I hereby certify that this plan. specification or report <br />was prepared by me or under my direct supervision <br />and that I am a duly Licensed Professional Engineer <br />under the laws of the State of Minnesota. <br />Signed: <br />Print Name: Nick Hanson <br />Date: 11.15-22 License Number: 46665 <br />3407 Kilmer Lane North <br />Suite 4 <br />Plymouth. MN 55441 <br />Tel 612-748-3572 <br />www.hansongroupmn.com <br />Wunderlich Residence <br />2726 Caroline Ave <br />Orono, MN <br />Project Number: 2.563 <br />Date: November 15. 2022 <br />Sheets: 1 of 3 <br />S3 <br />rn 0 <br />�o <br />LC) z LC) <br />L0 CD <br />�00 <br />z w <br />Q <br />woo <br />LL I� <br />w o <br />z @ r� <br />CZ•R� a LL <br />LL <br />V J .. <br />M z <br />x <br />0 <br />J LL <br />Q <br />ww <br />�~ w <br />06wi�i <br />z o <br />Y ,t <br />V�zo <br />eel 3o <br />w (/) <br />Z� 00 <br />�o E_ 00 <br />Z g LL <br />im, ZQ i;:� <br />LL: < 3:. <br />10 <br />C2 L <br />d w d <br />W <br />I2 <br />0 <br />0 <br />w <br />L) <br />nW <br />1� <br />w QIi <br />lI 0 <br />W ww <br />z Z <br />az <br />0 <br />1.4 c0 p <br />^W� <br />I� <br />DATE: <br />11-3-22 <br />REVISIONS: <br />11-10-22 <br />11-16-22 <br />3-31-23 <br />4-6-23 <br />4-10-23 <br />6-14-23 <br />DRAWN BY: <br />JJ <br />COMM. NO. <br />222249 <br />SHEET NO. <br />53 <br />