My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic Design 685 Pinehurst Ct
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
685 Pinehurst Court - 06-117-23-33-0012
>
Septic
>
Septic Design 685 Pinehurst Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:10 PM
Creation date
8/7/2023 9:23:43 AM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Pinehurst
Street Type
Court
Address
685 Pinehurst Ct
Document Type
Septic
PIN
0611723330012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />:)u7o Larger LanK wnn nruuipte comp/ Lan KS <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />36 GPM @ 32 ft. of head, Pump required <br />8.2 inch swing on Demand float which translates to roughly 5.1 inches of float tether length <br />Optional Time dosing of: <br />20 inches from bottom of tank to "pump ON" float, or 8.5 hours OFF <br />23 inches from bottom of tank to "Hi Level Alarm" or H12inches to "timer ON" float <br />inches to "Hi level" float <br />125 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />14 inch, or 1.2 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.0 ft. tong =ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 9 ft. upstope berm <br />ffi <br />sideslope 15 ft. sideslope berms <br />downslope 1 24 Ift. downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslope berm 0 l z� <br />Ito Downslope berm 0 <br />12" cover on sides <br />{6" loamy cap & 6" topsoil) <br />1.2 Clean sand lift <br />_ 1.8 Depth to Limiting <br />t_imiting Condition — — — — _ _ <br />Absorption Width z7. -- - ----- <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1 %, Absorption Width is measured downhill from the upslope edge of the Bed <br />Rock Bed: 21.0 yd' or *1.4= 29 ton 6 inches under pipe <br />Mound Sand: 199 yd3 or *1.4= 279 ton calculation based on 3:114:1 slope from top of rockbe, <br />Loamy Cap: 78 yd or *1.4= 109 ton 6" deep <br />Topsoil: 89 yd or *1.4= 125 ton 6" deep <br />INSPECTOR CHECKLIST - mound <br />6135 Finenurst court <br />